EN 13284-2-2004 en Stationary source emissions - Determination of low range mass concentration of dust - Part 2 Automated measuring systems《固定源排放物射 灰尘低范围质量浓度的测定 第2部分 自动化测量系统》.pdf
《EN 13284-2-2004 en Stationary source emissions - Determination of low range mass concentration of dust - Part 2 Automated measuring systems《固定源排放物射 灰尘低范围质量浓度的测定 第2部分 自动化测量系统》.pdf》由会员分享,可在线阅读,更多相关《EN 13284-2-2004 en Stationary source emissions - Determination of low range mass concentration of dust - Part 2 Automated measuring systems《固定源排放物射 灰尘低范围质量浓度的测定 第2部分 自动化测量系统》.pdf(28页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS EN 13284-2:2004 Stationary source emissions Determination of low range mass concentration of dust Part 2: Automated measuring systems The European Standard EN 13284-2:2004 has the status of a British Standard ICS 13.040.40 BS EN 13284-2:2004 This British Standard was published un
2、der the authority of the Standards Policy and Strategy Committee on 25 January 2005 BSI 25 January 2005 ISBN 0 580 45349 9 National foreword This British Standard is the official English language version of EN 13284-2:2004. The UK participation in its preparation was entrusted by Technical Committee
3、 EH/2, Air quality, to Subcommittee EH/2/1, Stationary source emissions, which has the responsibility to: A list of organizations represented on this subcommittee can be obtained on request to its secretary. Cross-references The British Standards which implement international or European publication
4、s referred to in this document may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online. This publication does not purport to include all the necessary
5、 provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpret
6、ation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 25 and a back cover. The BSI copyrig
7、ht notice displayed in this document indicates when the document was last issued. Amendments issued since publication Amd. No. Date CommentsEUROPEANSTANDARD NORMEEUROPENNE EUROPISCHENORM EN132842 September2004 ICS13.040.40 Englishversion StationarysourceemissionsDeterminationoflowrangemass concentra
8、tionofdustPart2:Automatedmeasuringsystems EmissionsdesourcesfixesDterminationdelafaible concentrationenmassedepoussiresPartie2: Systmesautomatiquesdemesure EmissionenausstationrenQuellenErmittlungder Staubmassenkonzentrationbeigeringen StaubkonzentrationenTeil2:Automatische Messeinrichtungen ThisEur
9、opeanStandardwasapprovedbyCENon22July2004. CENmembersareboundtocomplywiththeCEN/CENELECInternalRegulationswhichstipulatetheconditionsforgivingthisEurope an Standardthestatusofanationalstandardwithoutanyalteration.Uptodatelistsandbibliographicalreferencesconcernings uchnational standardsmaybeobtained
10、onapplicationtotheCentralSecretariatortoanyCENmember. ThisEuropeanStandardexistsinthreeofficialversions(English,French,German).Aversioninanyotherlanguagemadebytra nslation undertheresponsibilityofaCENmemberintoitsownlanguageandnotifiedtotheCentralSecretariathasthesamestatusast heofficial versions. C
11、ENmembersarethenationalstandardsbodiesofAustria,Belgium,Cyprus,CzechRepublic,Denmark,Estonia,Finland,France, Germany,Greece,Hungary,Iceland,Ireland,Italy,Latvia,Lithuania,Luxembourg,Malta,Netherlands,Norway,Poland,Portugal, Slovakia, Slovenia,Spain,Sweden,SwitzerlandandUnitedKingdom. EUROPEANCOMMITT
12、EEFORSTANDARDIZATION COMITEUROPENDENORMALISATION EUROPISCHESKOMITEEFRNORMUNG ManagementCentre:ruedeStassart,36B1050Brussels 2004CEN Allrightsofexploitationinanyformandbyanymeansreserved worldwideforCENnationalMembers. Ref.No.EN132842:2004:EEN 13284-2:2004 (E) 2 Contents page Foreword3 Introduction .
13、4 1 Scope 5 2 Normative references 5 3 Terms and definitions .5 4 Principle7 5 AMS performance criteria for QAL1.7 6 AMS location 9 7 Calibration and validation of the AMS (QAL2)9 7.1 General9 7.2 Calibration procedure .9 7.3 Establishing the calibration function.10 7.4 Calibration under abnormal op
14、erating conditions.10 7.5 Special circumstances in fulfilling the variability test.11 8 Ongoing quality assurance during operation (QAL3)12 9 Annual surveillance test (AST).12 Annex A (informative) Example of calculation of the calibration function and of the variability test.13 Annex B (informative
15、) Number of measurement points for calibration22 Annex C (informative) Quadratic regression .23 Bibliography 25 EN 13284-2:2004 (E) 3 Foreword This document (EN 13284-2:2004) has been prepared by Technical Committee CEN/TC 264 “Air quality”, the secretariat of which is held by DIN. This European Sta
16、ndard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by March 2005, and conflicting national standards shall be withdrawn at the latest by March 2005. This document has been prepared under a mandate given to CEN by the Eu
17、ropean Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s). For relationship with EU Directive(s), see informative bibliography, which is an integral part of this document. According to the CEN/CENELEC Internal Regulations, the national standard
18、s organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slova
19、kia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EN 13284-2:2004 (E) 4 Introduction This document describes the quality assurance procedures related to Automated Measuring Systems (AMS) for the determination of dust in flue gas, in order to meet the uncertainty requirements on measured
20、values given by regulations, e.g. EC Directives (1, 2), national or other legislation. This document is only applicable in conjunction with the general document on quality assurance of AMS described in EN 14181, and provides indications which are specific to dust measurements. The calibration and va
21、lidation of dust AMS are performed by parallel measurements with the reference manual gravimetric method described in EN 13284-1. EN 13284-2:2004 (E) 5 1 Scope This document specifies specific requirements on automated measuring systems (AMS) for dust monitoring. It is derived from EN 14181 which is
22、 the general document on the quality assurance of AMS. It is only applicable in conjunction with EN 14181. This document specifies test criteria for the QAL1 and specific requirements for QAL2, QAL3 and AST for dust AMS used for proving that the dust emissions from a source are compliant with emissi
23、on limits below 50 mg/m 3(standard conditions) in ducted gaseous streams. This document is applicable by direct correlation with the standard reference method (SRM) described in EN 13284-1. This document is primarily developed for emissions from waste incinerators. From a technical point of view, it
24、 may be applied to other processes, for which measurement at an emission limit is required with defined uncertainty. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated ref
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN1328422004ENSTATIONARYSOURCEEMISSIONSDETERMINATIONOFLOWRANGEMASSCONCENTRATIONOFDUSTPART2AUTOMATEDMEASURINGSYSTEMS

链接地址:http://www.mydoc123.com/p-707563.html