ECA 512-1-1990 Standard Methods for Measurement of the Equivalent Electrical Parameters of Quartz Crystal Units 1 kHz to 1 GHz《1kHz至1GHz石英晶体振子等效电气参数测量的标准方法》.pdf
《ECA 512-1-1990 Standard Methods for Measurement of the Equivalent Electrical Parameters of Quartz Crystal Units 1 kHz to 1 GHz《1kHz至1GHz石英晶体振子等效电气参数测量的标准方法》.pdf》由会员分享,可在线阅读,更多相关《ECA 512-1-1990 Standard Methods for Measurement of the Equivalent Electrical Parameters of Quartz Crystal Units 1 kHz to 1 GHz《1kHz至1GHz石英晶体振子等效电气参数测量的标准方法》.pdf(50页珍藏版)》请在麦多课文档分享上搜索。
1、ANSI/EIA-512-1 ADOPT ION NOT I CE ANSl/EiA-512-1, OlStandard Methods for Measurement of the Equivalent Electrical Parameters of Quartz Crystal Units, 1 kHz to 1 GHz,“ was adopted on 12 September 1994, for use by the Department of Defense (Da). Proposed changes by DoD activities must be submitted to
2、the DoD Adopting Activity: Laboratory, ATTN: AUSRL-EP-RD, Fort Monnouth, NJ 07703-5601. standard from the Defense Printing Service Detachment Office, Building 4D (Customer Service), 700 Robbins Avenue, Philadelphia, PA 19111-5094. ALL private sector and other Goverwnt agencies may purchase copies fr
3、om the Electronic Industries Association, 2001 Eye Street, N.U., Uashington, D.C. 20006. U.S. Army Research DoD activities may obtain copies of this Custodians: Amr/ - ER Navy - EC Air Force - 85 NASA - NA Review Activities: Army - AR, MI, SM Navy - AS, CG, MC, OS. SH Air Force - 17, 19, 99 MSC N/A
4、1 of 1 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. Adopting Activity: Army - ER Agent: DLA - ES (Project 5955-0634-01 ) FSC 5955 r I a In I w l- a - EIA 532-3 90 W 3234b00 0072873 8 = APPROVED: November 12, 1990 EIA STANDARD Standard Methods dor Measurement of t
5、he Equivalent Electrical Parameters of Quartz Crystal Units, 1 kHz to 1 GHz EIA-512-6 (Addendum No. 1 to EIA-512) DECEMBER 1990 ELECTRONIC INDUSTRIES ASSOCIATION ENGINEERING DEPARTMENT EIA 512-1 90 3234b00 0072872 T W D b NOTICE EIA Engineering Standards and Publications are designed to serve the pu
6、blic interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for his particular need. Existence of such Standards and
7、 Publications shall not in any respect preclude any member or nonmember of EL4 from manufacturing or selling products not conforming to such Standards and Publications, nor shall the existence of such Standards and Publications preclude their voluntary use by those other than EIA members, whether th
8、e standard is to be used either domestically or internationally. Recommended Standards and Publications are adopted by EL4 without regard to whether their adoption may involve patents on articles, materials, or processes. By such action, ETA does not assume any liability to any patent owner, nor doe
9、s it assume any obligation whatever to parties adopting the Recommended Standard or Publication. This EIA Standard is considered to have International Standardization implication, but the International Electrotechnical Commission activity has not progressed to the point where a valid comparison betw
10、een the EIA Standard and the IEC document can be made. This Standard does not purport to address all safety problems associated with its use or all applicable regulatory requirements. It is the responsibility of the user of this Standard to establish appropriate safety and health practices and to de
11、termine the applicability of regulatory limitations before its use. (From Standards Proposal No. 2200 formulated under the cognizance of the EIA P-11 Committee on Quartz Crystals.) COPYRIGHT 1991 Published by ELECTRONIC INDUSTRIES ASSOCIATION Engineering Department 2001 Pennsylvania Ave. N.W., Washi
12、ngton, D.C. 20006 PRICE: Please refer to the current Catalog of EIA even users who buy “complete“ measurement systems, which include equipment, fixtures, and software, must still be aware of how to make accurate measurements and how to verify system performance. This guide will provide the needed in
13、formation to do so, EIA-512 is complete in describing scattering parameter (S-parameter) theory, error correction techniques and in deriving the quartz crystal electrical parameter equations. For that reason, no attempt is made to review or summarize the standard. Instead, only information that adds
14、 to the understanding and use of the standard is included in the guide. Some material from the IECs Technical Committee No. 49 document, “A Guide To The Measurement of Equivalent Parameters Of Quartz Crystal Units“ was used in preparing this guide. EIA 512-1 90 W 3234600 0072875 5 M EIA-5 12 - 1 Pag
15、e 2 2.0 OVERVIEW OF MEASUREMENT METHODS 2.1 EQUIVALENT NETWORKS A proper equivalent circuit should represent the entire crystal unit as seen from the reference plane at the test fixture. It should include all the effects of leads, mountings and enclosure. It should also include crystal parameter dep
16、endency on frequency, drive level, and temperature. The effects of any mechanically or electrically coupled modes should be taken into account. Except for any nonlinear amplitude behavior, a quartz crystal unit can be quite accurate1 represented by the equivalent circuit in Figure 2.1 A description
17、of each circuit element I ollows: cPl The electrical surrounding ground planes. capacitance between each connecting pin and the The electrical capacitance between the pins. The equivalent resistances of the mounting structure. The electrical capacitance between the two electrodes. The electrical cap
18、acitances between the electrodes and the surrounding ground planes. The resistance between the electrodes. cPP Rpl, Rp2 Ce Ce19Ce2 RS I The equivalent electrical parameters of the design mode of resonance. R,N, L,N, C1,N The equivalent electrical parameters of other modes of resonance. here so that
19、the user is aware that complete characterization of a quartz crystal requires careful interpretation of measurements. The frequency and quality of the unit under test should be taken into account. Fortunately, this degree of sophistication is seldom needed. The circuit is reproduced For most applica
20、tions the following conditions are valid: a) Within a couple of percent frequency range of the mode of interest, there are no effects of interfering modes. Stated another way, R1, L1, C1 are constant over the frequency range of interest. b) $1 =RPl2+ ($1)/ and Xp2=Rp22+ are each much less than XI =
21、R12+ (wL1- l/wCl) 3 2 1/2 -EIA 512-1 90 3234600 0072876 7 W (This condition should be checked for frequencies above 300 MHz.) c) R, Xi The following terms can be combined: EIA- 5 12 - 1 Page 3 e) Co = Ce + Cpp This results in the simplified equivalent circuit of Figure 2.2a for a two-port, three ter
22、minal quartz crystal. For a one-port measurement, the stray capacitances are combined with Co and the equivalent circuit can be represented as shown in Figure 2.2b. This circuit representation is also used for glass enclosed quartz crystals regardless of whether the two-port or one-port method is us
23、ed. Since the stray capacitances will differ in each case, the values of Co will not be the same. (Fs) (the series resonance frequency of the series arm) is relatively independent of Co and any stray capacitance, it should be used to correlate EIA-512 one-port and two-port d measurements. When selec
24、ting crystals to correlate other measurement systems, select those units that do not show motional parameter dependency on small variations in drive level. Also select units that exhibit a good circle fit in the admittance plane. A good fit guarantees that there are no interfering modes of vibration
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ECA51211990STANDARDMETHODSFORMEASUREMENTOFTHEEQUIVALENTELECTRICALPARAMETERSOFQUARTZCRYSTALUNITS1KHZTO1GHZ1KHZ

链接地址:http://www.mydoc123.com/p-704047.html