1、 REVISIONS LTR DESCRIPTION DATE (YR-MO-DA) APPROVED A Changes in accordance with NOR 5962-R114-96. 96-04-22 K. A. Cottongim B Update drawing requirements to MIL-PRF-38534. 01-03-16 Raymond Monnin C Rewrite paragraphs 4.2.a.2. and 4.3.3.b.2 to add TC. 04-07-16 Raymond Monnin D Updated drawing paragra
2、phs. -sld 12-08-07 Charles F. Saffle REV SHEET REV SHEET REV STATUS OF SHEETS REV D D D D D D D D D D D SHEET 1 2 3 4 5 6 7 8 9 10 11 PMIC N/A PREPARED BY Gary Zahn DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 http:/www.landandmaritime.dla.mil/ STANDARD MICROCIRCUIT DRAWING CHECKED BY Michael C.
3、Jones THIS DRAWING IS AVAILABLE FOR USE BY ALL DEPARTMENTS APPROVED BY Kendall A. Cottongim MICROCIRCUIT, HYBRID, LINEAR, 90-VOLT, SYNCHRO TO DIGITAL CONVERTER AND AGENCIES OF THE DEPARTMENT OF DEFENSE DRAWING APPROVAL DATE 95-03-17 AMSC N/A REVISION LEVEL D SIZE A CAGE CODE 67268 5962-94544 SHEET 1
4、 OF 11 DSCC FORM 2233 APR 97 5962-E268-12 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-94544 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL D SHEET 2 DSCC FORM 2234 APR 97 1. SCOPE 1.1 Scop
5、e. This drawing documents five product assurance classes as defined in paragraph 1.2.3 and MIL-PRF-38534. A choice of case outlines and lead finishes which are available and are reflected in the Part or Identifying Number (PIN). When available, a choice of radiation hardness assurance levels are ref
6、lected in the PIN. 1.2 PIN. The PIN shall be as shown in the following example: 5962 - 94544 01 H X X Federal RHA Device Device Case Lead stock class designator type class outline finish designator (see 1.2.1) (see 1.2.2) designator (see 1.2.4) (see 1.2.5) / (see 1.2.3) / Drawing number 1.2.1 Radiat
7、ion hardness assurance (RHA) designator. RHA marked devices shall meet the MIL-PRF-38534 specified RHA levels and shall be marked with the appropriate RHA designator. A dash (-) indicates a non-RHA device. 1.2.2 Device type(s). The device type(s) identify the circuit function as follows: Device type
8、 Generic number Circuit function Frequency Accuracy 1 LSB 01 SD-14552DX-112 90 V S/D converter 400 Hz 4 min 02 SD-14554DX-112 90 V S/D converter 60 Hz 4 min 03 SD-14552DX-114 90 V S/D converter 400 Hz 2 min 04 SD-14554DX-114 90 V S/D converter 60 Hz 2 min 1.2.3 Device class designator. This device c
9、lass designator shall be a single letter identifying the product assurance level. All levels are defined by the requirements of MIL-PRF-38534 and require QML Certification as well as qualification (Class H, K, and E) or QML Listing (Class G and D). The product assurance levels are as follows: Device
10、 class Device performance documentation K Highest reliability class available. This level is intended for use in space applications. H Standard military quality class level. This level is intended for use in applications where non-space high reliability devices are required. G Reduced testing versio
11、n of the standard military quality class. This level uses the Class H screening and In-Process Inspections with a possible limited temperature range, manufacturer specified incoming flow, and the manufacturer guarantees (but may not test) periodic and conformance inspections (Group A, B, C, and D).
12、E Designates devices which are based upon one of the other classes (K, H, or G) with exception(s) taken to the requirements of that class. These exception(s) must be specified in the device acquisition document; therefore the acquisition document should be reviewed to ensure that the exception(s) ta
13、ken will not adversely affect system performance. D Manufacturer specified quality class. Quality level is defined by the manufacturers internal, QML certified flow. This product may have a limited temperature range. Provided by IHSNot for ResaleNo reproduction or networking permitted without licens
14、e from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-94544 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL D SHEET 3 DSCC FORM 2234 APR 97 1.2.4 Case outline(s). The case outline(s) are as designated in MIL-STD-1835 and as follows: Outline letter Descriptive designator Terminals P
15、ackage style X See figure 1 34 Dual-in-line, staggered pins 1.2.5 Lead finish. The lead finish shall be as specified in MIL-PRF-38534. 1.3 Absolute maximum ratings. 1/ Positive supply voltage (VCC) +7.0 V dc Reference input voltage 130 V rms Digital input voltage range -0.3 V dc to +7.0 V dc Power d
16、issipation, TA = +125 C (PD) 170 mW Thermal resistance junction-to-case (qJC) 8.0 C/W Thermal resistance junction-to-ambient (qJA) 20 C/W Storage temperature range -65 C to +150 C Lead temperature (soldering, 10 seconds) . +300 C 1.4 Recommended operating conditions. Positive supply voltage (VCC) +4
17、.75 V dc to +5.25 V dc Reference input voltage range. 10 V rms to 130 V rms Reference input carrier frequency range: Device types 01 and 03. 360 Hz to 5000 Hz Device types 02 and 04. 47 Hz to 1000 Hz Signal input voltage range 81 V rms to 99 V rms Ambient operating temperature range (TA) -55 C to +1
18、25 C 2. APPLICABLE DOCUMENTS 2.1 Government specification, standards, and handbooks. The following specification, standards, and handbooks form a part of this drawing to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or cont
19、ract. DEPARTMENT OF DEFENSE SPECIFICATION MIL-PRF-38534 - Hybrid Microcircuits, General Specification for. DEPARTMENT OF DEFENSE STANDARDS MIL-STD-883 - Test Method Standard Microcircuits. MIL-STD-1835 - Interface Standard for Electronic Component Case Outlines. DEPARTMENT OF DEFENSE HANDBOOKS MIL-H
20、DBK-103 - List of Standard Microcircuit Drawings. MIL-HDBK-780 - Standard Microcircuit Drawings. (Copies of these documents are available online at https:/assist.dla.mil/quicksearch/ or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.2 O
21、rder of precedence. In the event of a conflict between the text of this drawing and the references cited herein, the text of this drawing takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 1/ Stresses above t
22、he absolute maximum ratings may cause permanent damage to the device. Extended operation at the maximum levels may degrade performance and affect reliability. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-9
23、4544 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL D SHEET 4 DSCC FORM 2234 APR 97 3. REQUIREMENTS 3.1 Item requirements. The individual item performance requirements for device classes D, E, G, H, and K shall be in accordance with MIL-PRF-38534. Compliance with MIL-PRF-38534 shall
24、include the performance of all tests herein or as designated in the device manufacturers Quality Management (QM) plan or as designated for the applicable device class. The manufacturer may eliminate, modify, or optimize the tests and inspections herein, however, the performance requirements as defin
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLASMD596294544REVD2012MICROCIRCUITHYBRIDLINEAR90VOLTSYNCHROTODIGITALCONVERTERPDF

链接地址:http://www.mydoc123.com/p-700452.html