1、 REVISIONS LTR DESCRIPTION DATE (YR-MO-DA) APPROVED A Table IA; For IInRipple Current (IRIP) test. In Group A subgroups column correct footnote from “6/” to “7/” two places. gc 11-11-02 Charles F. Saffle B Table IA: Efficiency test, for device type 02 correct minimum efficiency from “80” to “79” per
2、cent and for device type 03 correct minimum efficiency from “81” to “80” percent. For Vout Step Line Transient remove “4/”. gc 11-12-14 Charles F. Saffle REV SHEET REV B B SHEET 15 16 REV STATUS REV B B B B B B B B B B B B B B OF SHEETS SHEET 1 2 3 4 5 6 7 8 9 10 11 12 13 14 PMIC N/A PREPARED BY Gre
3、g Cecil DLA LAND AND MARITIME STANDARD MICROCIRCUIT DRAWING CHECKED BY Greg Cecil COLUMBUS, OHIO 43218-3990 http:/www.landandmaritime.dla.mil/ THIS DRAWING IS AVAILABLE FOR USE BY ALL DEPARTMENTS APPROVED BY Charles F. Saffle MICROCIRCUIT, HYBRID, LINEAR, DUAL CHANNEL, DC-DC CONVERTER AND AGENCIES O
4、F THE DEPARTMENT OF DEFENSE DRAWING APPROVAL DATE 11-10-25 AMSC N/A REVISION LEVEL SIZE A CAGE CODE 67268 5962-11214 B SHEET 1 OF 16 DSCC FORM 2233 APR 97 5962-E112-12 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE
5、 A 5962-11214 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL B SHEET 2 DSCC FORM 2234 APR 97 1. SCOPE 1.1 Scope. This drawing documents five product assurance classes as defined in paragraph 1.2.3 and MIL-PRF-38534. A choice of case outlines and lead finishes which are available and
6、are reflected in the Part or Identifying Number (PIN). When available, a choice of radiation hardness assurance levels are reflected in the PIN. 1.2 PIN. The PIN shall be as shown in the following example: 5962 P 11214 01 K X X Federal RHA Device Device Case Lead stock class designator type class ou
7、tline finish designator (see 1.2.1) (see 1.2.2) designator (see 1.2.4) (see 1.2.5) / (see 1.2.3) / Drawing number 1.2.1 Radiation hardness assurance (RHA) designator. RHA marked devices shall meet the MIL-PRF-38534 specified RHA levels and shall be marked with the appropriate RHA designator. A dash
8、(-) indicates a non-RHA device. 1.2.2 Device type(s). The device type(s) identify the circuit function as follows: Device type Generic number Circuit function 01 SVFL2805D DC-DC Converter, 100 W, 5 V Outputs 02 SVFL2812D DC-DC Converter, 110 W, 12 V Outputs 03 SVFL2815D DC-DC Converter, 120 W, 15 V
9、Outputs 1.2.3 Device class designator. This device class designator shall be a single letter identifying the product assurance level. All levels are defined by the requirements of MIL-PRF-38534 and require QML Certification as well as qualification (Class H, K, and E) or QML Listing (Class G and D).
10、 The product assurance levels are as follows: Device class Device performance documentation K Highest reliability class available. This level is intended for use in space applications. H Standard military quality class level. This level is intended for use in applications where non-space high reliab
11、ility devices are required. G Reduced testing version of the standard military quality class. This level uses the Class H screening and In-Process Inspections with a possible limited temperature range, manufacturer specified incoming flow, and the manufacturer guarantees (but may not test) periodic
12、and conformance inspections (Group A, B, C, and D). E Designates devices which are based upon one of the other classes (K, H, or G) with exception(s) taken to the requirements of that class. These exception(s) must be specified in the device acquisition document; therefore the acquisition document s
13、hould be reviewed to ensure that the exception(s) taken will not adversely affect system performance. D Manufacturer specified quality class. Quality level is defined by the manufacturers internal, QML certified flow. This product may have a limited temperature range. Provided by IHSNot for ResaleNo
14、 reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-11214 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL B SHEET 3 DSCC FORM 2234 APR 97 1.2.4 Case outline(s). The case outline(s) are as designated in MIL-STD-1835 and as follow
15、s: Outline letter Descriptive designator Terminals Package style X See figure 1 12 Side Lead, Flange Mount 1.2.5 Lead finish. The lead finish shall be as specified in MIL-PRF-38534. 1.3 Absolute maximum ratings. 1/ Input Voltage (Continuous) . +40 V dc Input Voltage (Transient, 1 second) +50 V dc Po
16、wer Dissipation (PD, Full Load, TCASE= +125C) . 40 W Output Power (Dependant on Output Voltage) . 120 W Junction Temperature Rise to Case . +15 C Storage Temperature -65 C to +150 C Lead Solder Temperature (10 seconds) . +270 C 1.4 Recommended operating conditions. Input Voltage Range +16 V dc to +4
17、0 V dc Case Operating Temperature Range (TC) . -55 C to +125 C 1.5 Radiation features. Maximum total dose available (dose rate = 30 - 300 rad(Si)/s) . 30 krad (Si) 3/ Maximum total dose available (dose rate 10 mrad(Si)/s) LDR: Components: 30 krad (Si) 3/ 4/ Hybrid: 5/ Single event phenomenon (SEP) e
18、ffective linear energy threshold (LET): SEL, SEB, SEGR, SEFI . 44 MeV-cm2/mg 2/ 6/ 2. APPLICABLE DOCUMENTS 2.1 Government specification, standards, and handbooks. The following specification, standards, and handbooks form a part of this drawing to the extent specified herein. Unless otherwise specif
19、ied, the issues of these documents are those cited in the solicitation or contract. DEPARTMENT OF DEFENSE SPECIFICATION MIL-PRF-38534 - Hybrid Microcircuits, General Specification for. DEPARTMENT OF DEFENSE STANDARDS MIL-STD-883 - Test Method Standard Microcircuits. MIL-STD-1835 - Interface Standard
20、 for Electronic Component Case Outlines. 1/ Stresses above the absolute maximum ratings may cause permanent damage to the device. Extended operation at the maximum levels may degrade performance and affect reliability. 2/ Single event performance is tested with minor transients only; no dropouts, sh
21、utdowns, latch up or burn out. 3/ Bipolar device types may degrade from displacement damage from radiation which could affect RHA levels. These device types have not been characterized for displacement damage. 4/ Components: The bipolar, BiCMOS linear and mixed signal semiconductor components have b
22、een tested to High Dose Rate (HDR) Condition C (30-300 rad(Si)/s) and Low Dose Rate (LDR) per condition D of MIL-STD-883, method 1019. The difference between HDR and LDR test results has been compared to determine if the semiconductors exhibit ELDRS effect. Low dose rate sensitivity was not demonstr
23、ated. 5/ Hybrid: Hybrid devices have been tested at HDR. LDR testing on the device has not been completed. 6/ See table IB. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-11214 DLA LAND AND MARITIME COLUMBUS
24、, OHIO 43218-3990 REVISION LEVEL B SHEET 4 DSCC FORM 2234 APR 97 DEPARTMENT OF DEFENSE HANDBOOKS MIL-HDBK-103 - List of Standard Microcircuit Drawings. MIL-HDBK-780 - Standard Microcircuit Drawings. (Copies of these documents are available online at https:/assist.daps.dla.mil/quicksearch/ or from th
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLASMD596211214REVB2011MICROCIRCUITHYBRIDLINEARDUALCHANNELDCDCCONVERTERPDF

链接地址:http://www.mydoc123.com/p-698496.html