DLA SMD-5962-00526 REV B-2006 MICROCIRCUIT HYBRID LINEAR 5-VOLT SINGLE CHANNEL DC-DC CONVERTER《线性混合微电路5V单通道直流-直流变换器》.pdf
《DLA SMD-5962-00526 REV B-2006 MICROCIRCUIT HYBRID LINEAR 5-VOLT SINGLE CHANNEL DC-DC CONVERTER《线性混合微电路5V单通道直流-直流变换器》.pdf》由会员分享,可在线阅读,更多相关《DLA SMD-5962-00526 REV B-2006 MICROCIRCUIT HYBRID LINEAR 5-VOLT SINGLE CHANNEL DC-DC CONVERTER《线性混合微电路5V单通道直流-直流变换器》.pdf(13页珍藏版)》请在麦多课文档分享上搜索。
1、 REVISIONS LTR DESCRIPTION DATE (YR-MO-DA) APPROVED A Drawing updated to reflect current requirements. -sld 02-12-16 Raymond Monnin B Add paragraph 1.5 and note 2. Table I, add note for enhanced low dose rate effects. Paragraph 4.3.5.a, correct paragraph to add component tested dose rate. -sld 06-11
2、-21 Raymond Monnin REV SHEET REV SHEET REV STATUS REV B B B B B B B B B B B B OF SHEETS SHEET 1 2 3 4 5 6 7 8 9 10 11 12 PMIC N/A PREPARED BY Steve L. Duncan DEFENSE SUPPLY CENTER COLUMBUS STANDARD MICROCIRCUIT DRAWING CHECKED BY Michael C. Jones COLUMBUS, OHIO 43218-3990 http:/www.dscc.dla.mil THIS
3、 DRAWING IS AVAILABLE FOR USE BY ALL DEPARTMENTS APPROVED BY Raymond Monnin AND AGENCIES OF THE DEPARTMENT OF DEFENSE DRAWING APPROVAL DATE 00-08-03 MICROCIRCUIT, HYBRID, LINEAR, 5-VOLT, SINGLE CHANNEL, DC-DC CONVERTER AMSC N/A REVISION LEVEL B SIZE A CAGE CODE 67268 5962-00526 SHEET 1 OF 12 DSCC FO
4、RM 2233 APR 97 5962-E090-07 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-00526 DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 REVISION LEVEL B SHEET 2 DSCC FORM 2234 APR 97 1. SCOPE 1.1 Scope. Th
5、is drawing documents five product assurance classes as defined in paragraph 1.2.3 and MIL-PRF-38534. A choice of case outlines and lead finishes which are available and are reflected in the Part or Identifying Number (PIN). When available, a choice of radiation hardness assurance levels are reflecte
6、d in the PIN. 1.2 PIN. The PIN shall be as shown in the following example: 5962 - 00526 01 H X X Federal RHA Device Device Case Lead stock class designator type class outline finish designator (see 1.2.1) (see 1.2.2) designator (see 1.2.4) (see 1.2.5) / (see 1.2.3) / Drawing number 1.2.1 Radiation h
7、ardness assurance (RHA) designator. RHA marked devices shall meet the MIL-PRF-38534 specified RHA levels and shall be marked with the appropriate RHA designator. A dash (-) indicates a non-RHA device. 1.2.2 Device type(s). The device type(s) identify the circuit function as follows: Device type Gene
8、ric number Circuit function 01 SLH2805S DC-DC converter, 1.5 W, 5 V output 1.2.3 Device class designator. This device class designator shall be a single letter identifying the product assurance level. All levels are defined by the requirements of MIL-PRF-38534 and require QML Certification as well a
9、s qualification (Class H, K, and E) or QML Listing (Class G and D). The product assurance levels are as follows: Device class Device performance documentation K Highest reliability class available. This level is intended for use in space applications. H Standard military quality class level. This le
10、vel is intended for use in applications where non-space high reliability devices are required. G Reduced testing version of the standard military quality class. This level uses the Class H screening and In-Process Inspections with a possible limited temperature range, manufacturer specified incoming
11、 flow, and the manufacturer guarantees (but may not test) periodic and conformance inspections (Group A, B, C and D). E Designates devices which are based upon one of the other classes (K, H, or G) with exception(s) taken to the requirements of that class. These exception(s) must be specified in the
12、 device acquisition document; therefore the acquisition document should be reviewed to ensure that the exception(s) taken will not adversely affect system performance. D Manufacturer specified quality class. Quality level is defined by the manufacturers internal, QML certified flow. This product may
13、 have a limited temperature range. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-00526 DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 REVISION LEVEL B SHEET 3 DSCC FORM 2234 APR 97 1.2.4 Case outl
14、ine(s). The case outline(s) are as designated in MIL-STD-1835 and as follows: Outline letter Descriptive designator Terminals Package style X See figure 1 7 Dual-in-line 1.2.5 Lead finish. The lead finish shall be as specified in MIL-PRF-38534. 1.3 Absolute maximum ratings. 1/ Input voltage range -0
15、.5 V dc to +50 V dc Power dissipation (PD) . 2.0 W Output power . 1.56 W Lead soldering temperature (10 seconds) +300C Storage temperature range -65C to +150C 1.4 Recommended operating conditions. Input voltage range +16 V dc to +40 V dc Case operating temperature range (TC). -55C to +125C 1.5 Radia
16、tion features. Maximum total dose available (dose rate = 9 rad(Si)/s) . 100 krad (Si) 2/ 2. APPLICABLE DOCUMENTS 2.1 Government specification, standards, and handbooks. The following specification, standards, and handbooks form a part of this drawing to the extent specified herein. Unless otherwise
17、specified, the issues of these documents are those cited in the solicitation or contract. DEPARTMENT OF DEFENSE SPECIFICATIONS MIL-PRF-38534 - Hybrid Microcircuits, General Specification for. DEPARTMENT OF DEFENSE STANDARDS MIL-STD-883 - Test Method Standard Microcircuits. MIL-STD-1835 - Interface S
18、tandard Electronic Component Case Outlines. DEPARTMENT OF DEFENSE HANDBOOKS MIL-HDBK-103 - List of Standard Microcircuit Drawings. MIL-HDBK-780 - Standard Microcircuit Drawings. (Copies of these documents are available online at http:/assist.daps.dla.mil/quicksearch/ or http:/assist.daps.dla.mil or
19、from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 1/ Stresses above the absolute maximum ratings may cause permanent damage to the device. Extended operation at the maximum levels may degrade performance and affect reliability. 2/ These part
20、s may be dose rate sensitive in a space enviroment and may demonstrate enhanced low dose rate effects. Radiation end-point limits for the the noted parameters are guaranteed only for the conditions as specified in MIL-STD-883, method 1019, condition C, tested at 9 rad(Si)/s. Provided by IHSNot for R
21、esaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-00526 DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 REVISION LEVEL B SHEET 4 DSCC FORM 2234 APR 97 2.2 Order of precedence. In the event of a conflict between the text of th
22、is drawing and the references cited herein, the text of this drawing takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 Item requirements. The individual item performance requirements for
23、device classes D, E, G, H, and K shall be in accordance with MIL-PRF-38534. Compliance with MIL-PRF-38534 shall include the performance of all tests herein or as designated in the device manufacturers Quality Management (QM) plan or as designated for the applicable device class. The manufacturer may
24、 eliminate, modify or optimize the tests and inspections herein, however the performance requirements as defined in MIL-PRF-38534 shall be met for the applicable device class. In addition, the modification in the QM plan shall not affect the form, fit, or function of the device for the applicable de
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLASMD596200526REVB2006MICROCIRCUITHYBRIDLINEAR5VOLTSINGLECHANNELDCDCCONVERTER 线性 混合 电路 通道 直流 变换器 PDF

链接地址:http://www.mydoc123.com/p-698186.html