1、 AMSC N/A FSC 5920 INCH-POUND MIL-PRF-15160/3H 15 October 2008 SUPERSEDING MIL-PRF-15160/3G 7 July 2006 PERFORMANCE SPECIFICATION SHEET FUSES, INSTRUMENT, POWER, AND TELEPHONE (NONINDICATING), STYLE F03 This specification is approved for use by all Departments and Agencies of the Department of Defen
2、se. The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-PRF-15160. NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for general information only. FIGURE 1. Style F03, fuse. Inches mm 0.004 0.10 0.010 0.25 0.031 0.79 0.230 5
3、.84 0.250 6.35 1.250 31.75 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-15160/3H 2 REQUIREMENTS: Interface and physical dimensions: See figure 1. Terminals: Ferrule type. Material: Brass, copper, or copper alloy. Finish: Nickel, or silver
4、plated when specified. Strength: Method 211 of MIL-STD-202, test condition E, 2 inch-pound torque between ferrules and fuse body. Body: Plastic or ceramic tube. Electrical: Current rating: See table I. Voltage rating: See table I. Characteristic: See table I. Overload interrupt: See table I (at all
5、temperatures between minus 55C and plus 85C). Short circuit interrupt: See table I. Shock: F03A 1/4A through 1/2A MIL-STD-202, method 213, test condition I F03A 1A through 30A MIL-STD-202, method 207, (HI shock) F03B 1/100A through 8/10A MIL-STD-202, method 213, test condition I F03B 1A through 30A
6、MIL-STD-202, method 207, (HI shock) Vibration: F03A 1/4A through 30A MIL-STD-202, method 204, test condition A (except 5g peak) F03B 1/100A through 8/10A MIL-STD-202, method 201 F03B 1A through 30A MIL-STD-202, method 204, test condition A (except 5g peak) Type designation: Type designation shall be
7、 as specified in table I. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-TABLE I Type designations and electrical rating. See footnotes at end of table. Type designation Overload interrupt time 2/ Style Characteristic Maximum Current 135% of rating
8、Max. 1 hour AC short circuit interrupt. voltage rating 3/ (amperes) 200% of rating (seconds) 300% of rating (seconds) 32 volts 125 volts 250 volts F03 1/ A 250V 1/4A 0.02 2.0 0.01 0.20 10,000A 10,000A 35A F03 1/ A 250V 1/2A 0.03 3.0 0.01 0.30 10,000A 10,000A 35A F03 A 250V 1A 0.05 3.0 0.015 0.50 10,
9、000A 10,000A 35A F03 1/ A 250V 1 1/4A 0.05 3.0 0.02 0.50 10,000A 10,000A 35A F03 1/ A 250V 1 1/2A 0.05 3.0 0.02 0.50 10,000A 10,000A 35A F03 1/ A 250V 2A 0.08 3.0 0.04 0.50 10,000A 10,000A 35A F03 A 250V 3A 0.08 3.0 0.04 0.70 10,000A 10,000A 35A F03 1/ A 250V 4A 0.10 5.0 0.05 1.00 10,000A 10,000A 35
10、A F03 A 250V 5A 0.20 60.0 0.05 6.00 10,000A 10,000A 100A F03 1/ A 250V 6A 0.20 60.0 0.05 6.00 10,000A 10,000A 100A F03 A 250V 8A 0.30 60.0 0.05 6.00 10,000A 10,000A 100A F03 A 250V 10A 0.30 60.0 0.05 6.00 10,000A 10,000A 100A F03 A 250V 12A 0.30 60.0 0.05 6.00 10,000A 10,000A 200A F03 A 250V 15A 0.5
11、 60.0 0.05 6.00 10,000A 10,000A 200A F03 A 125V 20A 0.5 60.0 0.05 6.00 10,000A 10,000A Not rated F03 1/ A 125V 25A 0.5 60.0 0.05 6.00 10,000A 10,000A Not rated F03 A 125V 30A 0.5 60.0 0.05 6.00 10,000A 10,000A Not rated F03 B 250V 1/100A 4.0 250.0 2.0 40.0 10,000A 10,000A 35A F03 B 250V 1/32A 4.0 80
12、.0 2.0 25.0 10,000A 10,000A 35A F03 B 250V 1/16A 4.0 80.0 2.0 25.0 10,000A 10,000A 35A F03 1/ B 250V 1/10A 4.0 80.0 2.0 25.0 10,000A 10,000A 35A F03 B 250V 1/8A 4.0 80.0 2.0 25.0 10,000A 10,000A 35A F03 B 250V 15/100A 4.0 80.0 2.0 25.0 10,000A 10,000A 35A F03 B 250V 3/16A 4.0 80.0 2.0 25.0 10,000A 1
13、0,000A 35A F03 B 250V 1/4A 4.0 80.0 2.0 25.0 10,000A 10,000A 35A F03 1/ B 250V 3/10A 4.0 80.0 2.0 25.0 10,000A 10,000A 35A F03 B 250V 3/8A 4.0 80.0 2.0 25.0 10,000A 10,000A 35A MIL-PRF-15160/3H 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-TABLE
14、I Type designations and electrical rating - Continued. 1/ INACTIVE FOR NEW DESIGN AFTER 30 JANUARY 1970. 2/ The overload interrupt time ranges, as shown, cover the temperature range from minus 55C to plus 85C. For characteristic B, the overload interrupt time at room ambient temperature shall be not
15、 less than 12 seconds at 200 percent rating. 3/ For silver plated terminals the designator “S” is added after the current rating. Type designation Overload interrupt time 2/ Style Characteristic Maximum Current 135% of rating Max. 1 hour AC short circuit interrupt. voltage rating 3/ (amperes) 200% o
16、f rating (seconds) 300% of rating (seconds) 32 volts 125 volts 250 volts F03 B 250V 1/2A 4.0 80.0 2.0 25.0 10,000A 10,000A 35A F03 1/ B 250V 6/10A 4.0 80.0 2.0 25.0 10,000A 10,000A 35A F03 B 250V 3/4A 4.0 80.0 2.0 25.0 10,000A 10,000A 35A F03 1/ B 250V 8/10A 4.0 80.0 2.0 25.0 10,000A 10,000A 35A F03
17、 B 250V 1A 4.0 80.0 2.0 25.0 10,000A 10,000A 35A F03 1/ B 250V 1 1/4A 4.0 80.0 2.0 25.0 10,000A 10,000A 35A F03 1/ B 250V 1 1/2A 4.0 80.0 2.0 25.0 10,000A 10,000A 35A F03 1/ B 250V 1 6/10A 4.0 80.0 2.0 25.0 10,000A 10,000A 35A F03 1/ B 250V 2A 4.0 80.0 2.0 25.0 10,000A 10,000A 35A F03 B 250V 2 1/2A
18、10.0 250.0 2.0 25.0 10,000A 10,000A 35A F03 1/ B 250V 2 8/10A 10.0 250.0 2.0 25.0 10,000A 10,000A 35A F03 B 250V 3A 10.0 250.0 2.0 25.0 10,000A 10,000A 35A F03 1/ B 250V 3 2/10A 10.0 250.0 2.0 25.0 10,000A 10,000A 35A F03 1/ B 125V 4A 10.0 250.0 2.0 25.0 10,000A 10,000A Not rated F03 B 125V 5A 10.0
19、250.0 0.05 10.0 10,000A 10,000A Not rated F03 1/ B 125V 6 1/4A 10.0 250.0 0.05 10.0 10,000A 10,000A Not rated F03 1/ B 125V 7A 10.0 250.0 0.05 10.0 10,000A 10,000A Not rated F03 B 125V 8A 10.0 250.0 0.05 10.0 10,000A 10,000A Not rated F03 B 125V 10A 10.0 250.0 0.05 10.0 10,000A 10,000A Not rated F03
20、 B 125V 12A 10.0 250.0 0.05 10.0 10,000A 10,000A Not rated F03 B 125V 15A 10.0 250.0 0.05 10.0 10,000A 10,000A Not rated F03 B 125V 20A 10.0 250.0 0.05 10.0 10,000A 10,000A Not rated F03 1/ B 125V 25A 10.0 250.0 0.05 10.0 10,000A 10,000A Not rated F03 B 125V 30A 10.0 250.0 0.05 10.0 10,000A 10,000A
21、Not rated MIL-PRF-15160/3H 4 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-15160/3H 5 VERIFICATION: Qualification inspection is not applicable for the 1/4A, 1/2A characteristic A and the 1/100A, 1/32A, and 1/16A characteristic B fuses (see
22、table l) of this specification sheet and shall be replaced by acceptance testing consisting of Group A and Group B inspections per MIL-PRF-15160, prior to delivery. INSPECTION ROUTINE: Overload tests (group II): Fuses for the overload interrupt test shall be selected and tested as specified in table
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILPRF151603H2008FUSESINSTRUMENTPOWERANDTELEPHONENONINDICATINGSTYLEF03PDF

链接地址:http://www.mydoc123.com/p-692198.html