1、 INCH-POUND MIL-DTL-55668D February 20, 2009 SUPERSEDING MIL-DTL-55668C 9 September 2005 DETAIL SPECIFICATION CORD, ELECTRICAL; AUDIO, SUBMINIATURE (RETRACTILE AND STRAIGHT) Reactivated after 10 September 1993 and may be used for new and existing designs and acquisitions This specification is approv
2、ed for use by all Departments and Agencies of the Department of Defense 1. SCOPE 1.1 Scope. This specification covers subminiature audio helical retractile cords and straight cords with either stranded wire or tinsel wire conductors, for accessories associated in for the use with microphone, telepho
3、ne, switchboard, and associated communication equipment. These cords are intended for operations at audio frequencies and temperatures from -55 C to +85 C with a high degree of flexibility. Each retractile cord is designed for extension in normal service up to 6 times its nominal retracted helical l
4、ength. 1.2 Classification. The types of cords covered by this specification are classified as follows: Type I - Retractile cords with stranded wire conductors. Type II - Retractile cords with tinsel wire conductors. Type III - Straight cords with stranded wire conductors. Type IV - Straight cords wi
5、th tinsel wire conductors. 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are cited in sections 3, 4 or 5 of this specification. These lists do not include documents cited in other sections of this specification or recommended for additional information or as examples. Whi
6、le every effort has been made to ensure the completeness of these lists, document users are cautioned that they must meet the requirements specified in the documents cited in sections 3, 4 or 5 of this specification, whether or not they are listed. 2.2 Government documents. 2.2.1 Specifications, sta
7、ndards and handbooks. The following specifications, standards and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. FEDERAL STANDARD 2/18/20092/18/20091 1Beneficial comment
8、s, recommendations, addtions, deletions, clarifications, etc., and any data that may improve this document should be sent to: Defense Supply Center, Columbus, ATTN: DSCC-VAI, P.O. Box 3990, Columbus, Ohio 43218-3990, or email to WireCabledscc.dla.mil. Since contact information can change you may wan
9、t to verify the currency of this address informaiton using the ASSIST Online database at http:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-55668D 2 FEDERAL STANDARD FED-STD-228 - Cable and Wire, Insulated; Methods of
10、Testing. DEPARTMENT OF DEFENSE SPECIFICATIONS MIL-C-572 - Cords, Yarns, and Monofilaments, Organic Synthetic Fiber. MIL-I-631 - Insulation, Electrical, Synthetic Resin Composition Non-Rigid. DEPARTMENT OF DEFENSE STANDARDS MIL-STD-104 - Limits for Electrical Insulation Color. MIL-STD-202 - Test Meth
11、ods for Electronic and Electrical Component Parts. (Copies of these documents are available online at http:/assist.daps.dla.mil/quicksearch/ or from the Standardization Document Order 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.3 Non-Government publications. The following docume
12、nts form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. ASTM INTERNATIONAL ASTM D1248 - Standard Specification for Polyethylene Plastics Molding and Extrusion Materials. ASTM D4101 - S
13、tandard Specification for Propylene Plastic Injection and Extrusion Materials. ASTM B33 - Standard Specification for Tinned Soft or Annealed Copper Wire for Electrical Purposes. (Copies of these documents are available online from http:/www.astm.org or ASTM International, P.O. Box C700, 100 Barr Har
14、bor, West Conshohocken, PA 19428-2959.) Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-55668D 3 NATIONAL CONFERENCE STANDARDS LABORATORIES (NCSL) NCSL Z540.3 - General Requirements for Calibration of Measuring and Test Equipment (Copies of t
15、his document are available from http:/www.ncsli.org or from the National Conference of Standards Laboratories (NCSL), 2995 Wilderness Place, Suite 107, Boulder, CO 80301-5404.) INTERNATIONAL ORGANIZATION FOR STANDARDIZATION (ISO) ISO 10012-1 - Quality Assurance Requirements for Measurement Equipment
16、 / Metrological Confirmation System for Measuring Equipment. (Copies of these documents are available online at http:/www.iso.ch or from the International Organization for Standardization American National Standards Institute, 11 West 42ndStreet, 13thFloor, New York, NY 10036.) 2.4 Order of preceden
17、ce. Unless otherwise noted herein or in the contract, in the event of a conflict between the text of this document and the references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption ha
18、s been obtained. 3. REQUIREMENTS 3.1 First article. The cords furnished under this specification shall be products which have been tested to and have passed the first article inspection. First article approval is valid only on the contract under which it is granted, unless extended by the government
19、 to another contract (see 6.4). 3.2 Conductors. 3.2.1 Stranded wire. Each stranded wire shall be the equivalent of No. 26 American Wire Gauge (AWG) and shall consist of 26 strands of No. 40 AWG wire having a cross-sectional area of 9.9 circular mils and stranded with a .25 inch (6.35 mm) nominal, .3
20、8 inch (9.65 mm) maximum, unidirectional left-hand lay. The diameter of the stranded conductor shall be approximately .019 inch (.483 mm). Each strand shall be tinned, soft or drawn and annealed cadmium-copper alloy having a 1 percent, nominal, cadmium content and a minimum conductivity of 85 percen
21、t. 3.2.1.1 Tin-coating. Each strand shall be tin-coated with commercially pure tin. The tin-coating, continuity, adherence, and finish shall meet the requirements of ASTM B33 (see 4.7.2.1). 3.2.1.2 Stranded wire tensile strength and elongation. When tested as specified in 4.7.2.2, the tensile streng
22、th and elongation of the coated strands, removed from the wires of insulated conductors prior to cabling, shall be as follows: Tensile strength Elongation in 10 inches (254 mm) 40,000 psi (min.) 13 percent (min.) 3.2.1.3 Stranded wire resistance. Each strand shall have a direct current (dc) resistan
23、ce of not more than 1.27 ohms per foot. The dc resistance of the No. 26 stranded conductor shall be not more than .0556 ohms per foot. Resistance values should be measured at or corrected to 20 C when tested in accordance with 4.7.2.3 (see 6.3). Provided by IHSNot for ResaleNo reproduction or networ
24、king permitted without license from IHS-,-,-MIL-DTL-55668D 4 3.2.2 Tinsel wire. Tinsel wire shall meet the requirements type IV tinsel electrical wire, having an overall dimension of 0.022 inch (.56 mm) 0.002 inch (.05 mm) and a breaking load minimum of 10 pounds (see 6.3). 3.3 Insulation. The insul
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILDTL55668D2009CORDELECTRICALAUDIOSUBMINIATURERETRACTILEANDSTRAIGHTPDF

链接地址:http://www.mydoc123.com/p-691029.html