DLA MIL-DTL-55330 C-2001 CONNECTORS ELECTRICAL AND FIBER OPTIC PACKAGING OF《电连接器和光纤包装》.pdf
《DLA MIL-DTL-55330 C-2001 CONNECTORS ELECTRICAL AND FIBER OPTIC PACKAGING OF《电连接器和光纤包装》.pdf》由会员分享,可在线阅读,更多相关《DLA MIL-DTL-55330 C-2001 CONNECTORS ELECTRICAL AND FIBER OPTIC PACKAGING OF《电连接器和光纤包装》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、MIL-DTL-55330C8 JUNE 2001SUPERSEDINGMIL-C-55330B13 JULY 1988MILITARY SPECIFICATIONCONNECTORS, ELECTRICAL AND FIBER OPTIC, PACKAGING OFThis specification is approved for use by all Departments and Agencies of the Department of Defense.1. SCOPE1.1 Scope. This specification covers the requirements for
2、the preservation, packing, and containermarking of all types of electrical and fiber optic connectors (including interconnectors, splices, couplers,splitters, mixers, and associated accessories) which are primarily in FSCs 5935, 6005, and 6060 (see 6.1)2. APPLICABLE DOCUMENTS2.1 Government documents
3、.2.1.1 Specification and standards. The following specifications and standards form a part of thisspecification to the extent specified herein. Unless otherwise specified, the issues of these documentsshall be those listed in the issue of the Department of Defense Index of Specifications and Standar
4、ds(DoDISS) and supplement thereto, cited in the solicitation.SPECIFICATIONSFEDERALPPP-B-566 - Boxes, Folding, Paperboard.PPP-B-621 - Boxes, Wood, Nailed and Lock-Corner.PPP-B-676 - Boxes, Setup.AMSC N/A 1 of 9 AREA PACKDISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited.
5、Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be ofuse in improving this document should be addressed to: Defense Supply Center Columbus, ATTN:VAI, 3990 East Broad Street, Columbus, OH 43213-1199 by using the self-addressed StandardizationDocument Impro
6、vement Proposal (DD form 1426) appearing at the end of this document or by letter.INCH-POUNDProvided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-55330C2STANDARDSFEDERALFED-STD-123 - Marking for shipment (Civic Agencies).DEPARTMENT OF DEFENSEMIL-ST
7、D-129 - Standard Practice for Military Marking.MIL-STD-202 - Test Methods for Electronic and Electrical Component Parts.MIL-HDBK-774 - Palletized Unit Loads.MIL-STD-2073-1 - Standard Practice for Military Packaging.(Unless otherwise indicated, copies of the above specifications, standards, and handb
8、ooks areavailable from the Defense Printing Service Detachment Office, Standardization Document Order Desk,Building 4D Customer Service, 700 Robbins Avenue, Philadelphia, PA 19111-5094.)2.2 Non-Government publications. The following documents form a part of this document to the extentspecified herei
9、n. Unless otherwise specified, the issues of the documents which are DoD adopted arethose listed in the issue of the DoDISS cited in the solicitation. Unless otherwise specified, the issues ofdocuments not listed in the DoDISS are the issues of the documents cited in the solicitation (see 6.2).AMERI
10、CAN SOCIETY OF QUALITY CONTROL (ASQC)ASQC Z1.4 - Procedures, Sampling and Tables For Inspection By Attributes.(Applications for copies should be addressed to the American Society of Quality Control, 611 EastWisconsin Avenue , Milwaukee, Wisconsin, 53202.)AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI)A
11、NSI/NCSL Z540.1 - Laboratories, Calibration, and Measuring and Test Equipment.(Applications for copies should be addressed to the American National Standards Institute, 11 West42ndStreet, New York, NY 10036.)AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM)ASTM-D1974 - Fiberboard Boxes, Methods of C
12、losing, Sealing, and Reinforcing.ASTM-D3951 - Packaging, Commercial.ASTM-D-3953 - Steel, and Seals, Flat, Strapping.ASTM-D6251 - Natural Wood-Cleated, Panel Board, Shipping Boxes.(Applications for copies should be addressed to the American Society for Testing and Materials, 100Barr Harbor Drive, Wes
13、t Conshohocken, PA 19428-2959.)(Non-Government standards and other publications are normally available from the organizations whichprepare or, which distribute the documents. These documents also may be available in or throughlibraries or other informational services.)Provided by IHSNot for ResaleNo
14、 reproduction or networking permitted without license from IHS-,-,-MIL-DTL-55330C32.3 Order of precedence. In the event of a conflict between the text of this document and thereferences cited herein, the text of this document takes precedence. Nothing in this document, however,supersedes applicable
15、laws and regulations unless a specific exemption has been obtained.3. REQUIREMENTS3.1 General. The packaging terms used herein shall be in accordance with the definitions listed in MIL-STD-129, and MIL-STD-2073-1. The following general requirements apply, as applicable, to militaryor commercial pack
16、aging as well as to shipments to Non-Government activities.3.1.1 Hardware. Mounting brackets, screws, and other hardware accompanying or furnished with theconnectors shall be protected and enclosed within the unit packs in a manner that will not damage theconnectors or the packaging materials. When
17、practical, the hardware should be mounted on eachconnector.3.1.2 Physical protection. Connectors and accessories shall be packaged in a manner that will ensurecompliance with the applicable requirements of MIL-STD-2073-1 as well as those specified herein. Forshipments to non-Government activities, l
18、arge quantity unit packs may be used.3.1.2.1 Contacts, leads, and terminals. Contacts, leads, terminals, and other outward projections shallbe protected by means of container design, noncorrosive die-cut inserts, or other suitable supportingmaterials or devices. If not otherwise protected, protectiv
19、e caps shall be used to prevent damage to thecoupling or accessory connector threads.3.1.2.2 Wrapping and cushioning. Wrapping and cushioning materials shall be noncorrosive and dry.In addition, materials used for fiber optic connectors shall be nonstatic generating and shall not crumble,flake, powd
20、er or shed. Cushioning is not required for accessories.3.1.3 Exterior containers. Exterior containers shall be of minimum tare and cube consistent with theprotection required and shall contain quantities of identical stock numbered or otherwise designated itemsto the greatest extent practicable (see
21、 3.3).3.2 Preservation. Preservation shall be military or commercial, as specified (see 6.2).3.2.1 Military.3.2.1.1 Cleaning. Connectors and accessories shall be cleaned in accordance with MIL-STD-2073-1.3.2.1.2 Drying. Connectors and accessories shall be dried in accordance with MIL-STD-2073-1.3.2.
22、1.3 Preservatives. Contact preservatives shall not be used.3.2.1.4 Unit packs.3.2.1.4.1 Connectors. Unless otherwise specified (see 6.2), and except as specified herein,connectors (both electrical and fiber optic) shall be individually unit packed in accordance with MIL-STD-2073-1, method 41. Electr
23、ical connectors with only gold plated contacts shall be preserved inaccordance with MIL-STD-2073-1, method 31.3.2.1.4.1.1 Connectors with removable contacts. Removable crimp type contacts shall not be installedin the connector insert but shall be placed in a close fitting noncorrosive rigid containe
24、r such as a vial orbox and enclosed within the unit pack. Any spare contacts furnished shall also be within this container.3.2.1.4.1.2 Connectors with grommet sealing plugs. Grommet sealing plugs supplied with variousconnectors shall be placed in an envelope or rigid container and enclosed within th
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILDTL55330C2001CONNECTORSELECTRICALANDFIBEROPTICPACKAGINGOF 连接器 光纤 包装 PDF

链接地址:http://www.mydoc123.com/p-691021.html