1、 Comments, suggestions or questions on this document should be addressed to Defense Supply Center Columbus, ATTN: VAT, Post Office Box 3990, Columbus, OH 43218-3990, or emailed to switchdla.mil. Since contact information can change, you may want to verify the currency of this address information usi
2、ng the ASSIST Online database at http:/assist.daps.dla.mil. AMSC N/A FSC 5930 INCH-POUND MIL-DTL-12211G 5 February 2009 SUPERSEDING MIL-DTL-12211F 10 March 2003 DETAIL SPECIFICATION SWITCH, PRESSURE This specification is approved for use by all Departments and Agencies of the Department of Defense.
3、1. SCOPE 1.1 Scope. This specification covers two types of automotive pressure switches (see 6.1). Type I switches operate when fluid pressures drop below predetermined values and type II switches operate when fluid pressures exceed predetermined values. 1.2 Classification. Switches furnished under
4、this specification will be of the following types and classes as specified (see 6.2). All switches shall be (waterproof). Type I - Sufficiently low pressure closes contacts. Type II - Sufficiently high pressure closes contacts. Class 1 - High vibration (see 6.4). Class 2 - Low vibration (see 6.4). 2
5、. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are specified in sections 3 and 4 of this specification. This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. While every effort has bee
6、n made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirements documents cited in sections 3 and 4 of this specification, whether or not they are listed. Provided by IHSNot for ResaleNo reproduction or networking permitted without license
7、from IHS-,-,-MIL-DTL-12211G 2 2.2 Government documents. 2.2.1 Specifications, standards, and handbooks. The following specifications, standards, and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the
8、 solicitation or contract. FEDERAL STANDARDS FED-STD-H28 - Screw Thread Standards for Federal Services. DEPARTMENT OF DEFENSE SPECIFICATIONS MIL-DTL-12211/1 - Switch, Pressure, SPST, Waterproof. DEPARTMENT OF DEFENSE STANDARDS MIL-STD-130 - Identification Marking of US Military Property. MIL-STD-202
9、 - Electronic and Electrical Component Parts. MIL-STD-810 - Environmental Engineering Considerations and Laboratory Test. MIL-STD-889 - Dissimilar Metals. MS27152 - Switch, Pressure-Warning. Low Air Pressure 60 PSI, SPST, Waterproof. MS75062 - Switch, Pressure-Stoplight, Vehicular, Air Brake System,
10、 24 Volt, Waterproof. MS75063 - Switch, Pressure-Stoplight, Vehicular, Hydraulic Brake System,24 Volt, Waterproof. MS90530 - Switch, Pressure-Warning SPST, Waterproof, 24 Volt, DC. (Copies of these documents are available online at http:/assist.daps.dla.mil/quicksearch/ or from the Standardization D
11、ocument Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.2.2 Other Government documents, drawings, and publications. The following other Government documents, drawings, and publications form a part of this document to the extent specified herein. Unless otherwise specifie
12、d, the issues of these documents are those cited in the solicitation. DRAWINGS ARMY 7321326 - Sending Unit, Low Oil Pressure Warning. 11669414 - Switch, Pressure. (Copies of drawings required by contractors in connection with specific acquisition functions should be obtained from the acquiring activ
13、ity, or as directed by the contracting officer.) Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-12211G 3 2.3 Non-Government publications. The following documents form a part of this document to the extent specified herein. Unless otherwise s
14、pecified, the issues of these documents are those cited in the solicitation or contract (see 6.2). AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) ANSI/NCSL Z540-1 - Laboratories, Calibration, and Measuring and Test Equipment. INTERNATIONAL ORGANIZATION for STANDARDS (ISO) ISO 10012-1 - Equipment, Qual
15、ity Assurance Requirements for Measuring - Part 1: Meteorological Confirmation System for Measuring Equipment. (Applications for copies can be obtained online at www.ansi.org or through the American National Standards Institute, 11 West 42ndStreet New York, NY 10036). AMERICAN SOCIETY FOR TESTING AN
16、D MATERIALS (ASTM) ASTM B117 - Salt spray (Fog) Apparatus, Operating. (Application for copies can be obtained online at www.astm.org or through the American Society for Testing and Materials, 100 Barr Harbor Dr., West Conshohocken, PA 19428-2959.) (Non-Government standards and other publications are
17、 normally available from the organizations that prepare or distribute the documents. These documents also may be available in or through libraries or other informational services.) 2.4 Order of precedence. Unless otherwise noted herein or in the contract, in the event of a conflict between the text
18、of this document and the references cited herein (except for related specification sheets), the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 Qualification. The
19、switches furnished under this specification shall be products which are authorized by the qualifying activity for listing on the applicable qualified products list at the time of award of contract (see 4.3 and 6.3). 3.2 Materials. Materials shall be as specified herein and in referenced specificatio
20、ns, standards and drawings. Material shall be free of defects that adversely affect performance or serviceability of the finished product (see 4.7.1). 3.2.1 Dissimilar metals. Dissimilar metals shall be protected from galvanic corrosion in accordance with requirements of MIL-STD-889 (see 4.7.1). 3.2
21、.2 Pure tin. The use of pure tin, as an underplate or final finish, is prohibited both internally and externally. Tin content of switch components and solder shall not exceed 97 percent, by mass. Tin shall be alloyed with a minimum of 3 percent lead, by mass (see 6.5). 3.3 Interface and physical dim
22、ensions. Switches shall conform to MS27152, MS75062, MS75063 or MS90530, Drawings 7321326 or 11669414; and to other applicable standards or drawings, as specified (see 4.7.1, 4.7.2 and 6.2). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-122
23、11G 4 3.3.1 Threaded parts. Screw threads of the form, number per inch, and class specified on the applicable drawing or military standard shall be in accordance with FED-STD-H28 (see 4.7.2). 3.3.2 Rating. The switch shall be operated in nominal 24 volts (V) direct current (dc) electrical systems, a
24、nd shall operate a nominal 6 watt (3 candlepower) lamp, or loads as specified on applicable MS standards or drawings (see 4.7.2). 3.4 Performance. 3.4.1 Calibration (see 4.7.3). 3.4.1.1 Type I switches. Type I switches shall close on decreasing pressure within the pressure range specified on the app
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILDTL12211G2009SWITCHPRESSUREPDF