DIN EN 14212-2012 Ambient air - Standard method for the measurement of the concentration of sulphur dioxide by ultraviolet fluorescence German version EN 14212 2012《环境空气质量 利用紫外线荧光测.pdf
《DIN EN 14212-2012 Ambient air - Standard method for the measurement of the concentration of sulphur dioxide by ultraviolet fluorescence German version EN 14212 2012《环境空气质量 利用紫外线荧光测.pdf》由会员分享,可在线阅读,更多相关《DIN EN 14212-2012 Ambient air - Standard method for the measurement of the concentration of sulphur dioxide by ultraviolet fluorescence German version EN 14212 2012《环境空气质量 利用紫外线荧光测.pdf(108页珍藏版)》请在麦多课文档分享上搜索。
1、November 2012 Translation by DIN-Sprachendienst.English price group 31No part of this translation may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).I
2、CS 13.040.20!$N“1924393www.din.deDDIN EN 14212Ambient air Standard method for the measurement of the concentration of sulphurdioxide by ultraviolet fluorescence;English version EN 14212:2012,English translation of DIN EN 14212:2012-11Auenluft Messverfahren zur Bestimmung der Konzentration von Schwef
3、eldioxid mitUltraviolett-Fluoreszenz;Englische Fassung EN 14212:2012,Englische bersetzung von DIN EN 14212:2012-11Air ambiant Mthode normalise pour le mesurage de la concentration en dioxyde de soufre parfluorescence U.V.;Version anglaise EN 14212:2012,Traduction anglaise de DIN EN 14212:2012-11Supe
4、rsedesDIN EN 14212:2005-06www.beuth.deIn case of doubt, the German-language original shall be considered authoritative.Document comprices 108 pages 10.12This standard has been included in the VDI/DIN Handbook on air quality, Volume 5. DIN EN 14212:2012-11 2A comma is used as the decimal marker. Base
5、d on Corrigendum EN 14212:2012/AC:2014-04, the English version of DIN EN 14212:2012-11 has been corrected as follows: Re Subclause 8.4.12 “Averaging test” Figure 2 “Concentration variations for the averaging effect test” has been replaced with a new figure. Re E.2 “Type approval Requirement a)” In T
6、able E.1, in the rows “Short term drift at zero” (No. 13) and “Short term drift at span level” (No. 14), “Dl,z” and “Dl,s” respectively has been replaced with “Ds,z” and “Ds,s”. Re G.2 “Combined standard uncertainty” In Equation (G.3) and its related key, “lh” has been replaced twice with “ld”. Re H
7、.3 “Standard uncertainties” Equation (H.21) and its related key have been corrected. DIN EN 14212:2012-11 3 Previous editions DIN EN 14212: 2005-06 National foreword This standard has been prepared by Technical Committee CEN/TC 264 “Air quality” (Secretariat: DIN, Germany), Working Group WG 12 “Refe
8、rence method for determination of SO2/NO2/O3/CO in ambient air” (Secretariat: NEN, Netherlands). The responsible German body involved in its preparation was the Kommission Reinhaltung der Luft (KRdL) im VDI und DIN Normenausschuss (Commission on Air Pollution Prevention of VDI and DIN Standards Comm
9、ittee). Amendments This standard differs from DIN EN 14212:2005-06 as follows: a) Clause 1 “Scope”: the scope has been extended to include information for different groups of users; b) Subclauses 8.1 and 8.3: normative references to EN 15267-1 and EN 15267-2 have been included; c) Subclause 8.4.2.3,
10、 Table 4: the requirements for impurities in zero gas have been relaxed for other than interferents tests; d) Subclauses 9.4 and 9.6: the performance requirements for some performance characteristics have been tightened. Additional performance criteria and tests have been introduced for repeatabilit
11、y at zero and span levels; e) Subclause 9.5: formulae for software adjustment of the raw analyser signal after calibration have been introduced; f) Subclause 9.9 (new): general information on measurement uncertainty has been included; g) Clause 11: more stringent requirements have been specified for
12、 test reports and documentation; h) the former Annex C has been replaced by the reference to Directive 2008/50/EC (Subclause 6.2); i) Annex E.3 (previously F.3): the formulae for the calculation of the influence quantities have been modified; j) Annex G (new): the calculation of uncertainty in field
13、 operation at the daily limit value has been specified k)Annex E(previously F) to Annex H: examples of calculations have been modified/supplemented.DIN EN 14212:2012-11 4 National Annex NA (informative) Bibliography VDI 4202 Part 1, Performance criteria for performance tests of automated ambient air
14、 measuring systems Point-related measurement methods for gaseous and particulate air pollutants VDI 4203 Part 1, Testing of automated measuring systems General concepts VDI 4203 Part 3, Testing of automated measuring systems Test procedures for point-related ambient air measuring systems for gaseous
15、 and particulate air pollutants EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 14212 August 2012 ICS 13.040.20 Supersedes EN 14212:2005English Version Ambient air - Standard method for the measurement of the concentration of sulphur dioxide by ultraviolet fluorescence ir ambiant - Mthode norma
16、lise pour le mesurage de la concentration en dioxyde de soufre par fluorescence U.V. Konzentration von Schwefeldioxid mit Ultraviolett-Fluoreszenz This European Standard was approved by CEN on 10 May 2012. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the
17、conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard e
18、xists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national
19、standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia
20、, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2012 CEN All rights of exploitation in any form and by any means reserved world
21、wide for CEN national Members. Ref. No. EN 14212:2012: EA Au nluft - Messverfahren zur Bestimmung der eEN 14212:2012 (E) 2 Contents Foreword 41 Scope 52 Normative references 53 Terms and definitions . 64 Abbreviated terms . 115 Principle 115.1 General 115.2 Measuring principle . 115.3 Type approval
22、test . 125.4 Field operation and quality control 126 Sampling . 136.1 General 136.2 Sampling location 136.3 Sampling system . 136.4 Control and regulation of sample flow rate 146.5 Sampling pump for the manifold 147 Analyser equipment 157.1 General 157.2 Selective traps for interfering agents 157.3
23、Optical assembly . 157.4 Pressure measurement . 157.5 Flow rate indicator . 157.6 Sampling pump for the analyser 167.7 Internal sulphur dioxide span source 167.8 Particle filter . 168 Type approval of ultraviolet fluorescence sulphur dioxide analysers . 168.1 General 168.2 Relevant performance chara
24、cteristics and performance criteria . 178.3 Design change . 188.4 Procedures for determination of the performance characteristics during the laboratory test . 198.5 Determination of the performance characteristics during the field test 298.6 Type approval and uncertainty calculation . 339 Field oper
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DINEN142122012AMBIENTAIRSTANDARDMETHODFORTHEMEASUREMENTOFTHECONCENTRATIONOFSULPHURDIOXIDEBYULTRAVIOLETFLUORESCENCEGERMANVERSIONEN142122012

链接地址:http://www.mydoc123.com/p-667071.html