DIN EN 13126-11-2009 Building hardware - Requirements and test methods for windows and doors height windows - Part 11 Top hung projecting reversible hardware English version of DIN.pdf
《DIN EN 13126-11-2009 Building hardware - Requirements and test methods for windows and doors height windows - Part 11 Top hung projecting reversible hardware English version of DIN.pdf》由会员分享,可在线阅读,更多相关《DIN EN 13126-11-2009 Building hardware - Requirements and test methods for windows and doors height windows - Part 11 Top hung projecting reversible hardware English version of DIN.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、February 2009DEUTSCHE NORM English price group 10No part of this standard may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).ICS 91.190!$UvZ“1508355ww
2、w.din.deDDIN EN 13126-11Building hardware Requirements and test methods for windows and doors heightwindows Part 11: Top hung projecting reversible hardwareEnglish version of DIN EN 13126-11:2009-02Baubeschlge Beschlge fr Fenster und Fenstertren - Anforderungen und Prfverfahren Teil 11: Umkehrbeschl
3、ge fr auskragende Schwing-KlappflgelfensterEnglische Fassung DIN EN 13126-11:2009-02SupersedesDIN CEN/TS 13126-11:2004-08www.beuth.deDocument comprises 14 pagesDIN EN 13126-11:2009-02 2 National foreword This standard has been prepared by Technical Committee CEN/TC 33 “Doors, windows, shutters, buil
4、ding hardware and curtain walling” (Secretariat: AFNOR, France), Working Group WG 4 “Building hardware” (lead-management: BSI, United Kingdom). The responsible German body involved in its preparation was the Normenausschuss Bauwesen (Building and Civil Engineering Standards Committee), Technical Com
5、mittee NA 005-09-53 AA Fensterbeschlge. Amendments a) b) Examples of classification have been added. Previous editions DIN CEN/TS 13126-11: 2004-08 This standard differs from DIN CEN/TS 13126-11:2004-08 as follows: CEN/TS has been editorially revised. EUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORME
6、N 13126-11November 2008ICS 91.190 Supersedes CEN/TS 13126-11:2004 English VersionBuilding hardware - Requirements and test methods for windowsand doors height windows - Part 11: Top hung projectingreversible hardwareQuincaillerie pour le btiment - Exigences et mthodesdessai des ferrures de fentres e
7、t portes-fentres - Partie11: Ferrures pour ouvrants litalienne rversibles axehorizontal suprieurBaubeschlge - Beschlge fr Fenster und Fenstertren -Anforderungen und Prfverfahren - Teil 11:Umkehrbeschlge fr auskragende Schwing-KlappflgelfensterThis European Standard was approved by CEN on 5 October 2
8、008.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on
9、 application to the CEN Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the CEN Management Cent
10、re has the same status as theofficial versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland,
11、Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGManagement Centre: rue de Stassart, 36 B-1050 Brussels 2008 CEN All rights of exploitation in any form and by any mean
12、s reservedworldwide for CEN national Members.Ref. No. EN 13126-11:2008: EEN 13126-11:2008 (E) 2 Contents Page Foreword3 1 Scope.5 2 Normative references 5 3 Terms and definitions5 4 Classification6 4.1 General6 4.2 Category of use (1 first digit) .6 4.3 Durability (2 second digit)6 4.4 Mass (3 third
13、 digit) 6 4.5 Fire resistance (4 fourth digit) .6 4.6 Safety in use (5 fifth digit) 6 4.7 Corrosion resistance (6 sixth digit).6 4.8 Security (7 seventh digit) .6 4.9 Application (8 eighth digit).6 4.10 Test sizes Size limitations (9 ninth digit).6 4.11 Example of classification for top hung project
14、ing reversible hardware7 5 Requirements .7 5.1 General7 5.2 Integrated restrictors.7 5.3 Ease of sash movement test.7 5.4 Durability test .8 5.5 Static load test8 6 Test equipment.8 7 Test methods8 7.1 Samples 8 7.2 Ease of sash movement test procedure9 7.3 Durability test procedure.9 7.4 Static loa
15、d test procedure.10 7.5 Corrosion resistance .10 Annex A (informative) Test method diagrams11 Annex B (normative) Flow chart of test procedure12 DIN EN 13126-11:2009-02 EN 13126-11:2008 (E) 3 Foreword This document (EN 13126-11:2008) has been prepared by Technical Committee CEN/TC 33 “Doors, windows
16、, shutters, building hardware and curtain walling”, the secretariat of which is held by AFNOR. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by May 2009, and conflicting national standards shall be
17、 withdrawn at the latest by May 2009. This document supersedes CEN/TS 13126-11:2004. This European Standard is one of a series of European Standards dedicated to building hardware products. A full contribution to the preparation of this European Standard has been made by the European manufacturers o
18、rganization “ARGE” and national standards bodies. EN 13126 Building hardware Requirements and test methods for windows and doors height windows consists of the following parts: Part 1: Requirements common to all types of hardware Part 2: Casement fastener handles1)Part 3: Manoeuvring fittings for es
19、pagnolette bolts/sliding button1)Part 4: Espagnolette bolts1)Part 5: Devices that restrict the opening of windows1)Part 6: Variable geometry stay hinges (with or without a friction system) Part 7: Finger catches Part 8: Tilt Digit 2 durability grade 5 (25 000 cycles); Digit 3 mass 60 kg; Digit 4 fir
20、e resistance grade 0 (no requirements); Digit 5 safety in use grade 1; Digit 6 corrosion resistance grade 3; Digit 7 security - (no requirements); Digit 8 applicable part tested in accordance with Part 11 of this standard; Digit 9 test sizes S.R.W.1) = 1 500 mm, S.R.H.2)= 1 500 mm 5 Requirements 5.1
21、 General The requirements for top hung projecting reversible hardware shall be in accordance with Clause 5 of EN 13126-1:2006. 5.2 Integrated restrictors Where top hung projecting reversible hardware is fitted with an integrated restrictor the hardware shall be tested in accordance with CEN/TS 13126
22、-5. 5.3 Ease of sash movement test The test specified in 7.2 shall be used to determine the forces required to operate the hardware is appropriate for the intended use. On completion of the ease of sash movement test in accordance with 7.2. DIN EN 13126-11:2009-02 EN 13126-11:2008 (E) 8 Force requir
23、ed to initiate movement in either the opening or closing direction shall not have exceeded 100 N. Force required to sustain movement in either the opening or closing direction shall not have exceeded 100 N. 5.4 Durability test The test specified in 7.3 shall be used to ensure the hardware is capable
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DINEN13126112009BUILDINGHARDWAREREQUIREMENTSANDTESTMETHODSFORWINDOWSANDDOORSHEIGHTWINDOWSPART11TOPHUNGPROJECTINGREVERSIBLEHARDWAREENGLISHVERSIONOFDINPDF

链接地址:http://www.mydoc123.com/p-665647.html