DIN 28153-1-1994 Covers for DN 350 450 500 and 600 openings in glass-lined apparatuses《第1部分 口径公称尺寸为 DN 350 x 450、500 和 600 的玻璃衬里的仪器用闭锁盖》.pdf
《DIN 28153-1-1994 Covers for DN 350 450 500 and 600 openings in glass-lined apparatuses《第1部分 口径公称尺寸为 DN 350 x 450、500 和 600 的玻璃衬里的仪器用闭锁盖》.pdf》由会员分享,可在线阅读,更多相关《DIN 28153-1-1994 Covers for DN 350 450 500 and 600 openings in glass-lined apparatuses《第1部分 口径公称尺寸为 DN 350 x 450、500 和 600 的玻璃衬里的仪器用闭锁盖》.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、DEUTSCHE NORM Covers of nominal sizes DN 350 x 450, DN 500 and DN 600 for glass-lined steel vessels ADril 1994 DIN 28 153 Part 1 ICs 71.120.10 Supersedes the October 1983 edition of DIN 28 153 Part 1 and parts of the June 1985 edition of DIN 18145 Part 2. Verschludeckel fr Apparate aus Stahl, emaill
2、iert; Nennweiten DN 350 x 450, 500 und 600 In keeping with current practice in standards published by the International Organization for Standardization (ISO), a comma has been used throughout as the decimal marker. Dimensions in mm Page 2 Temperature/pressure ratings . 2 3 Type and design of covers
3、 2 4 Dimensions and designations . 2 4.1 Covers . 3 4.2 Welded fittings 11 4.3 Spacer rings 13 5 Materials 14 6 Marking . 14 7 Examples of application 14 1 Scope and field of application . 1 Standards referred to 15 1 Scope and field of application This standard specifies dimensions and materials fo
4、r the covers of manholes and access openings of sizes DN 350 x 450, DN 500 and DN 600 in glass-lined steel vessels, such as mixing vessels and DIN 28018 or DIN 28019 pressure vessels. It also covers dimensions and materials for spacer rings. DIN 28063 should be referred to for specifications regardi
5、ng test methods and requirements for glass-lined covers, and DIN 28153 Part 2 for DN 100 to DN 250 covers for glass-lined steel vessels. Continued on pages 2 to 16. uth Verlag GmbH, Berlin, has the exclusive right of sale for German Standards (DIN-Normen). DIN 28 153 Part 1 Engl. Price group 12 Sale
6、s No. O1 i2 12.95 Page 2 DIN 28 153 Part 1 6 2 Temperature/pressure ratings The covers shall be designed for the allowable working temperatures and pressures listed in table 1. Table 1: Temperature/pressure ratings 7 6 Allowable working temperature, in “C I -60 to 50 to 200 I Type Design features KZ
7、1) Hinged (K), with 1 centred nozzle (Zl) of nominal size DN 100 See figure 1 3 Type and design of covers Table 2 lists the types and designs of covers dealt with in this standard. KZAl) Nominal size DN Hinged (K), with a centred clearance (Z) to receive an inspection windowpaneoftypeEClOO-lO-X-H2as
8、in DIN28121 350 x 450 KHO) KE1) 500 Hinged (K), without nozzle (O) for horizontal (H) or inclined facing Hinged (K), with 1 off-centre nozzle (El), of nominal size DN 1 O0 500 and 600 SHO Pivoted (S), without nozzle (O), for horizontal (H) or inclined facing l5 SE1 ss2 svo 2 6 Pivoted (S), with 1 of
9、f-centre nozzle (El) of nominal size DN 100, for horizontal (H) or inclined facing 7 Pivoted (S), with 2 symmetrically arranged nozzles (S2) of nominal size DN 100, for horizontal (H) or inclined manhole Pivoted (S), without nozzle (O), for vertical (V) manhole 8 3 4 VD4 I Cover with 4 nozzles (VD4)
10、 19 I) Provisions should be made for a handle. 4 Dimensions and designations Dimensions for covers are subject to the general tolerances specified in DIN 28005 Part 2, as well as to the class c tolerances specified in IS0 2768-1. Welded fittings are subject to the class m tolerances specified in IS0
11、 2768-1. Covers, spacer rings and welded fittings are not expected to conform to the designs illustrated here; compliance is only required with regard to the specified dimensions. The specified dimensions refer to the steel surface and not the glass-lined surface of covers. Details not specified in
12、this standard should be selected as appropriate. DIN 28153 Pari 1 Page 3 4.1 Covers 4.1.1 Type KZl cover A-A 1 23 5 *T I 535 1 Handle as in subclause 4.2.4 2 DN 100 nozzle as in 28139 Part3 3 DIN 28150-A100-RSt 37-2 flange 4 Welded fitting as in subclause 4.2.1 5 Space for marking as in subclause 6
13、Figure 1: Type Ki1 cover The designation for a type KZ1 glass-lined steel (St-em) oval cover of nominal size DN 350 x 450 shall read: Cover DIN 28 153 - 350 x 450 - KZ1 - St-em Page 4 DIN 28 153 Part 1 4.1.2 Type KZA cover Type KZA covers are designed so that they can be fitted with a DIN 28121 insp
14、ection window pane of nominal size DN 100 (see first example in clause 7). Should an inspection window be requested, this shall be specified in the order. A-A 109 4 h, A For all other dimensions and details, see figure I. Figure 2 Type KZA cover The designation for a type KZA glass-lined steel (St-e
15、m) oval cover of nominal size DN 350 x 450 shall read: Cover DIN 28 153 - 350 x 450 - KZA - St-em 2, Minimum radius. DIN 28 153 Part 1 Page 5 4.1.3 Type KHO cover A-A I / / For all other dimensions and details, see figure 4. Figure 3 Type KHO cover Page 6 DIN 28 153 Pari 1 4.1.4 Type KE1 cover A-A 2
16、 3 4 0 500 610 * T i- A 1 Handle as in subclause 4.2.4 2 DN 100 nozzle as DIN 28139 Part 3 3 DIN 28 150 - Al O0 - RSt 37-2 flange 4 Welded fittings as in subclause 4.2.1 5 Marking space as in subclause 6 Figure4: Type KEl cover The designation for a type KE1 glass-lined steel (St-em) cover of nomina
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DIN2815311994COVERSFORDN350450500AND600OPENINGSINGLASSLINEDAPPARATUSES 部分 口径 公称 尺寸 DN350X450 500 600

链接地址:http://www.mydoc123.com/p-655646.html