CSA CGA 5 2-1971 Gas-Fired Waterless Toilet《燃气无水厕所 前一版本为B205 2》.pdf
《CSA CGA 5 2-1971 Gas-Fired Waterless Toilet《燃气无水厕所 前一版本为B205 2》.pdf》由会员分享,可在线阅读,更多相关《CSA CGA 5 2-1971 Gas-Fired Waterless Toilet《燃气无水厕所 前一版本为B205 2》.pdf(40页珍藏版)》请在麦多课文档分享上搜索。
1、CANADIAN GAS ASSOCIATION CGA 5,2 GAS-FIRED WATERLESS TOILET (FORMERLY CSA B205,2 ACCEPTED BY INTERPROVINCIAL GAS ADVISORY COUNCIL PUBLISHED DECEMBER 1971 EFFECTIVE DECEMBER 1972 SPONSORED BY CAMADIAN GAS ASSOCIATION 55 SCARSDALE ROAD DON MILLS, ONTARIO M3B 2R3 PRINTED IN CANADA REPRINTED SEPTEMBER,
2、1973 PREFACE This Standard, like all standards prepared by the Canadian Gas Association, is subjectto periodic review. Amendments in the form of replacement pages may be issued from time to time. To receive copies of these replacement pages, purchasers of this Standard should complete and return the
3、 attached card. Standards are updated in conjunction with changes in technology and are normally reviewed at least within a five year period. If the Standards Committee, industry and provincial inspection authorities feel the standard requires no change, then the standard may be reaffirmed and only
4、the date is changed. It should be noted that most CGA standards are published as National Standards of Canada. As the standards conform to the criteria and procedures established by the Standards Council of Canada, the Standard Number designation changes with the CGA prefix being replaced by CAN1 or
5、 CAN/CGA. Although any replacement pages that have been issued will be sold with the Standard, the purchaser must insert them where they apply. Replacement pages will show the date of the publication of the amendment. The effective date of the changes will be shown on the cover page of the amendment
6、 and is usually one year after publication. It is the responsibility of the purchaser to maintain his copy of the Standard and to retain those pages which have been replaced for reference purposes. Name Organization Address City Prov/State Country Postal/Zip Code Place Stamp Here CANADIAN GAS ASSOCI
7、ATION Standards Department 55 Scarsdale Road DON MILLS, Ontario M3B 2R3 CONTENTS List of IGAC Members iii List of CGA Committee Members . V Preface . vi PART I Gas-Fired Waterless Toilets for use with Propane Gas Construction Requirements 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 1.10 1.11 1.12 1.13 1.14
8、1.15 1.16 1.17 1.18 1.19 1.20 1.21 1.22 1.23 1.24 1.25 Scope . Assembly and Construction . Materials . Burners . Primary Air Control . Orifices and Orifice Fittings . Automatic Ignition Devices Pilot Burners and Safety Shut-Off Devices . Air Flow Control Automatic Valves Manual Valves . Gas Supply L
9、ines Legs Combustion Chambers . Charging Doors Linings . Insulation Flue Gas Temperature Limiting Means . Timing Devices Strength Deodorizers . Spark Plug Electrical Instructions Marking . 1 1. 2 3. 3 3Y4 4 4 495 5 6 697 7 7 7 8 8 8 9 9 9 9 9 10 10 r; 2 PART I1 Gas-Fired Waterless Toilets for use wi
10、th Other Than LP Gases 2.1 General Notes . 11 2.2 Test Gases 11 PART III Gas-Fired Waterless Toilets for use with Propane Gas Performance Requirements 3.1 General . 12 3.3 Burner Ratings 13 3.2 Test Gases 12. 13 3.4 Test Pressures and Burner Adjustments . 13 i 3.5 3.6 3.7 3.8 3.9 3.10 3.11 3.12 3.13
11、 3 . 14 3.15 3.16 Combustion 13. I!+ Burner Operating Characteristics 14. 15. 16 Pilot Operating Characteristics . 16. 17 Pilot Burners and Safety Shut-Off Devices . 17. 18. 19 Incinerating Effectiveness 20. 21 Smoke. Odor and Fly Ash Elimination Characterisitcs . 21. 22. 23 Wall. Floor and Flue Gas
12、 Temperature 23. 24 Timing Devices 24. 25 Purging Effectiveness . 25 Materials . 26 Strength 27 Wind Test for Sealed Comustion Toilets 29 Appendix A 31 ii January 1976 4 INTERPROVINCIAL GAS ADVISORY COUNCIL MEMBERS ALTERNATES H. A. LINES (Chairman) Chief Gas Inspector Department of Labour Occupation
13、al Health C, Safety Division Gas Safety Unit 1150 Rose Street REGINA, Saskatchewan S4R 126 L. ADRIAN Chief, Safety Division Department of Public Services Government of the Northwest Territories P. 0. Box 1200 YELLOWKNIFE, Northwest Territories XOE 1HO L. H. GILBERT Energy Safety Branch Technical Sta
14、ndards Division Ministry of Consumer C, Commercial Relations 400 University Avenue TORONTO, Ontario M5G 1S5 E. S. HORNBY Assistant Dominion Fire Commissioner Office of the Dominion Fire Commissioner Department of Public Works Sir Charles Tupper Building Riverside Drive OTTAWA, Ontario K1A OM2 R. J.
15、JACKSON Government of the Yukon Territory Department of Local Government P. 0. Box 2703 WHITEHORSE, Yukon Territory Y1A 2C6 H. K. JENNS Fire Marshal Office of the Provincial Fire Marshal 1620 West 8th Avenue Suite 275 VANCOUVER, British Columbia V6J 1V4 T. G. NAIRN K. H. COLLIER R. 3. C. LYONS Techn
16、ical Services Branch New Brunswick Department of Labour P. 0. Box 6000 Corner of Campbell C, Regent Streets FREDERICTON, New Brunswick E3B 5H1 iii MEMBERS ALTERNATES J. T. MERCER Chief Gas Inspector Gas Protection Branch Department of Manpower and Labour I.B.M. Building, 8th Floor 10808 - 99th Avenu
17、e EDMONTON, Alberta T5K OG5 W. R. MONTGOMERY Chief Gas Inspector Department of Public Works Safety Engineering Services Division 501 West 12th Avenue VANCOUVER, British Columbia V5Z 1M6 , L. A. OMORROW Director Mechanical 6 Engineering Division . Manitoba Department of Labour Norquay Building, Room
18、611 401 York Avenue WINNIPEG, Manitoba R3C OV8 V. H. PERRY LP - Gas Inspector Office of the Fire Marshal Nova Scotia Department of Labour P. 0. Box 697 IIALIFAX, Nova Scotia B3J 2T8 R. PRONOVOST Electricity and Gas Board Quebec Department of Natural Resources 2100 Drummond Street MONTREAL, Quebec H3
19、G .LX1 F. J. RYAN Fire Commissioner Government of Newfoundland 6 Labrador Pleasantville Fire Station ST. JOHNS, Newfoundland R. L. TAYLOR (Secretary) Canadian Gas Association 55 Scarsdale Road DON MILLS, OqtFrio V3B 2R3 F. R. FRASER M. RIENDEAU iv CGA STANDARDS COMMITTEE ON GAS-FIRED TOILETS, CGA 5.
20、2 MEMBERS ALTERNATES D. P. Frankel (Chairman) Clear Water, Inc. P. 0. Box 644 SHEBOYGAN , Wisconsin 53081 R. C. Helke Director of Research La Mere Industries Snc. 227 North Main Street WALWORTH, Wisconsin 53184 A. Gauthier Gauth Sales . If any indication is observed during the tests prescribed herei
21、n that the appliance will not continue to meet the requirements in normal usage, such supplementary life tests shall be made as will determine reasonably satisfactory service. 1.2.3 All parts such as main burner(s), pilot burner(s), orifice(s), and other parts which are subject to repair, cleaning o
22、r adjustment, shall be readily accessible and removable. -2- 1.2.4 All controls shall be accessible for normal servicing and functional adjustment in position. Manifold assemblies which peat removal of control(s) intact shall be considered to meet this requirement for servicing. door to secure acces
23、s to a control compartment shall be considered acceptable. Removal of a panel or 1.2.5 The construction and assembly of all parts, whether specifical.1.y mentioned in these repuirements or not, shall be in accordance with reasonable concepts of safety, substantiality and durability. 1.2.6 Toilets sh
24、all be accompanied by instructions and diagrams adequate for their proper installation and safe operation, including all controls and accessories. servicing from other than the top or front of the toilet, these instructions shall also include infortnation relative to minimum clearances necessary far
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CSACGA521971GASFIREDWATERLESSTOILET 燃气 无水 厕所 版本 B2052PDF

链接地址:http://www.mydoc123.com/p-621465.html