CEPT T CD 01-08 E-1985 Engineering Requirements for a Parallel Data Transmission Modem for Use in the GSTN《在GSTN中使用的并行数据传输调制解调器工程要求》.pdf
《CEPT T CD 01-08 E-1985 Engineering Requirements for a Parallel Data Transmission Modem for Use in the GSTN《在GSTN中使用的并行数据传输调制解调器工程要求》.pdf》由会员分享,可在线阅读,更多相关《CEPT T CD 01-08 E-1985 Engineering Requirements for a Parallel Data Transmission Modem for Use in the GSTN《在GSTN中使用的并行数据传输调制解调器工程要求》.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、CEPT T/CD*OL-OB*E 79 2326434 0003339 L T/CDQ-08 Page E 1 Recommendation T/CD O1 -08 E (Ostende 1979, revised at Cannes 1983) concerning the engineering requirements for a parallel data transmission modem for use in the general switched telephone network Recommendation proposed by Working Group T/WG
2、10 “Data Communications” (CD) Text of the revised Recommendation adopted by the “Telecommuiiicatiois” Commission : “The Conference of European Post and Telecommunications Administrations, Consider ihg - that Recommendation T/CD 01-01 contains the text of the Specifications of the general engineering
3、 requirements - that working group CD has studied the harmonization of modems under the auspices of Question CD 1. for data circuit terminating equipment for analogue and digital networks; Recommends - that the attached Specification of engineering requirements for a parallel data transmission modem
4、 for use in the general switched telephone network as contained in Annex I to this Recommendation should be taken into account by all CEPT Administrations when implementation of such a piece of equipment is being planned by Administrations are free to stipulate additional requirements, and also whic
5、h of the optional requirements, if any, are to be provided. Note 1: The Specification is subject of continuous study and possible amendment. Note 2: The Annex is an integral part of the Recommendation. O Administrations. Edition of November 30, 1985 T/CD 01-08 E Page 3 Annex 1. Contents Section A. C
6、omtnon requirements . 5 1. General 5 2. Data signalling rates . 5 3. Interfaces., 5 3.1. Instation modem interface 5 3.2. Outstation modem interface. . 6 3.3. Electrical characteristics . 6 4. Modulation and coding 7 5. Scrambling (not provided for) . 7 6. Timing . 7 7. . Backward channel 7 8. Line
7、signal characteristics. 7 9. Out-of-band interference . 8 10. Performance requirements. 8 11. Testing and measuring requirements. 8 12. Construction 9 13. Specific design requirements 9 14. Power supply 9 15. Environmental requirements 9 O Section B. Network dependent requirements No specific requir
8、ements. Parts of this specification which are literally copied from CCITT-Recommendations, are marked with a line in the margin of the paper. Sections which need further study, are marked with an asterisk. Edition of November 30, 1985 CEPT T/CD*OL-OB*E W 232b414 0003141 T = a a T/CD O1 -08 E Page 5
9、Section A. Common requirements 1. GENERAL The modems for parallel data transmission for one-way data transmission, where a large number of low-cost sending stations (outstations) transmit to a central receiving station (instation) are intended for use in the general switched telephone network only.
10、The modems must meet the requirements given in the Specification of the general engineering requirements (Recommendation T/CD 01-01) and in this specification. They must comply with CCITT Recommenda- tions V.20, V.241V.28 and V.31. The main characteristics of these recommended modems (outstation mod
11、em/instation modem) for parallel data transmission are as follows: (b) transmission of 64-character combinations from outstation to instation; (a) transmission of 16-character combinations (c) transmission of 256-character combinations (d) transmission of simple acknowledgement signals or analog sig
12、nals (voice-answering) from the instation to the outstation. The parallel data transmission system uses two or three times one out of four frequencies. 1 2. DATA SIGNALLING RATES The modulation rate is up to 40 characters per second. In the 16-character combination system the data signalling rates s
13、hall be up to 20 or up to 40 characters per second, in the other combination systems the data signalling rates shall be up to 20 characters per second. 3. INTERFACES 3.1. Instation modem interface The interchange circuits to be used are given in the list below. List of interchange circuits: 102 104
14、105 107 Data set ready. i08/1 Connect data set to line (see Note I). 109 118 120 121 125 Calling indicator. 130 191 i i0 124 Select frequency groups. 13 1 Received character timing. Note 1: These circuits shall be capable of being used as circuits 108/1: Connect data set to line or circuit 108/2: Da
15、ta terminal ready, depending upon its use. For automatic calling it shall be used as 108/2. Note 2: These circuits are required if the 75 bit/s frequency modulated backward channel is provided in the modem (see also Note 4). Note 3: This circuit is required if the 5 bit/s amplitude modulation backwa
16、rd channel is provided in the modem. Note 4; The pin allocation on the interface connector is the same for circuits 191A and 121 and 191B and 118, respectively. If both, the speech channel and the 75 bit/s backward channel shall be provided in the modem, means have to be provided to switch between t
17、hose circuits. The functions of the above interchange circuits are defined in the Specification of the general engineering requirements (Recommendation T/CD 01-01) and comply with CCITT Recommendation V.24. Signal ground or common return. Received data, 12 or 8 circuits depending on whether group B
18、is used or not. These received data circuits are designated Al, A2 . C4, each corresponding to its relevant frequency (see Table i). Request to send (see Note 2). 10812 Data terminal ready 1 Data channel received line signal detector. Transmitted backward channel data (see Note 2). Transmit backward
19、 channel line signal (see Note 2). Backward channel ready (see Note 2). Transmit backward tone (see Note 3). Transmitted voice answer (see Note 4). Data signal quality detector. Edition of November 30. 1 985 CEPT T/CD*OL-O*E 2326434 0003342 3 TICD O1 -08 E At outstation closing of circuit 1 2 3 None
20、 Page 6 3.1.1. 3.1.2. 3.1.3. 3.2. 3.2.1. 3.3. Number of the channel on line At instation negative polarity on circuit 1 1 2 2 3 3 4 4 Interchange circuit connector The allocation of the interchange circuits to pins of the connector is in conformance with IS0 Standard 2110. It is given in Figure 1. E
21、lectrical characteristics The electrical characteristics of the above interchange circuits are given in the Specification of the general engineering requirements (Recommendation T/CD O1 -01) and comply with CCITT Recommendation V.28. Electrical characteristics of interchange circuit 191 The impedanc
22、e and transmitter requirements must comply with the line requirements for the modem, which are given in the Specification of the general engineering requirements (Recommendation T/CD O1 -01). Outstation modem interface The interchange circuits to be used are given in the list below. List of intercha
23、nge circuits: 102 103 105 Request to send. 107 Data set ready. 108/1 108/2 Data terminal ready 119 122 125 Calling indicator. 129 Request to receive. Note 1: This circuit shall be capable of being used as circuit 108/1 “Connect data set to line” or circuit 108/2 “Data terminal ready”. For automatic
24、calling it shall be used as 108/2. Note 2: The transmitted data circuits (103) will all use the same common return (102). The control circuits may operate each on their own return circuit. Note 3: The pin allocation on the modem interface connector is the same for circuits 192 and 119. If both, the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CEPTTCD0108E1985ENGINEERINGREQUIREMENTSFORAPARALLELDATATRANSMISSIONMODEMFORUSEINTHEGSTN GSTN 使用 并行 数据传输

链接地址:http://www.mydoc123.com/p-592991.html