CEN TR 10354-2011 Chemical analysis of ferrous materials - Analysis of ferro-silicon - Determination of Si and Al by X-ray fluorescence spectrometry《黑色金属材料的化学分析 硅铁的分析 X射线荧光光谱法测定硅和铝.pdf
《CEN TR 10354-2011 Chemical analysis of ferrous materials - Analysis of ferro-silicon - Determination of Si and Al by X-ray fluorescence spectrometry《黑色金属材料的化学分析 硅铁的分析 X射线荧光光谱法测定硅和铝.pdf》由会员分享,可在线阅读,更多相关《CEN TR 10354-2011 Chemical analysis of ferrous materials - Analysis of ferro-silicon - Determination of Si and Al by X-ray fluorescence spectrometry《黑色金属材料的化学分析 硅铁的分析 X射线荧光光谱法测定硅和铝.pdf(24页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationPD CEN/TR 10354:2011Chemical analysis of ferrous materials Analysis of ferro-silicon Determination of Si and Al by X-ray fluorescence spectrometryIncorporating corrigendum March
2、2012PD CEN/TR 10354:2011 PUBLISHED DOCUMENTNational forewordThis Published Document is the UK implementation ofThe UK participation in its preparation was entrusted to Technical Committee ISE/102, Methods of Chemical Analysis for Iron and Steel.A list of organizations represented on this committee c
3、an be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. ISBN 978 0 580 77884 1 ICS 77.080.10 Compliance with a British Standard cannot confer immunity from legal obligations
4、.This Published Document was published under the authority of the Standards Policy and Strategy Committee on 30 November 2011.Amendments/corrigenda issued since publicationDate T e x t a f f e c t e dThe British Standards Institution 2012 Implementation of CEN correction noticePublished by BSI Stand
5、ards Limited 2012CEN/TR 10354:2011.31 March 201204 January 2012: Figures B.3 and B.4 replacedTECHNICAL REPORT RAPPORT TECHNIQUE TECHNISCHER BERICHT CEN/TR 10354 November 2011 ICS 77.080.10 English Version Chemical analysis of ferrous materials - Analysis of ferro-silicon - Determination of Si and Al
6、 by X-ray fluorescence spectrometryAnalyse chimique des matriaux ferreux - Analyse du ferro-silicium - Dtermination de Si et Al dans le ferro-silicium par spectromtrie de fluorescence de rayons X Chemische Analyse von Ferrolegierungen - Analyse von Ferrosilizium - Bestimmung von Si und Al in Ferrole
7、gierungen durch Rntgenfluoreszenzanalyse This Technical Report was approved by CEN on 24 April 2011. It has been drawn up by the Technical Committee ECISS/TC 102. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland,
8、France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITE
9、E FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2011 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. CEN/TR 10354:2011: E2 Contents Page Foreword 3 1 Scope 4 2 Principle 4 3 Reagents .5 4 Apparatus .5 5 Safety precau
10、tions .5 6 Sampling .5 7 Procedure .6 8 Expression of results 7 9 Precision .7 10 Test report 8 Annex A (informative) Test samples used for the precision test .9 Annex B (informative) Detailed results obtained from the precision test 10 Annex C (informative) Calibration curve - Preparation of oxide
11、beads with pure metals and/or oxides . 17 Bibliography . 19 PD CEN/TR 10354:2011CEN/TR 10354: 2011 (E)3 Foreword This document (CEN/TR 10354:2011) has been prepared by Technical Committee ECISS/TC 102 “Methods of chemical analysis for iron and steel”, the secretariat of which is held by SIS. Attenti
12、on is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. PD CEN/TR 10354:2011 CEN/TR 10354:2011 (E)4 1 Scope This Technical Report describes a X-ray f
13、luorescence (XRF) spectrometric method for the determination of Si and Al contents in ferro-silicon materials. The method is applicable to: Si contents between 40 % and 90 %; Al contents between 0,5 % and 6 %. The correction of the spectrometric measurement from spectral interferences on the analyti
14、cal lines used is essential. This Technical Report is valid for the analytical lines: Si K 7.126 (for element contents between 45 % and 90 %); Al K 8.339 (for element contents between 0,8 % and 6 %); Fe K 1.937 (for element contents between 10 % and 58 %). NOTE For matrix matching purposes, iron is
15、included in the analytical program to be prepared. Within the conditions here above, spectral interferences dont need to be calculated. 2 Principle Preparation of oxide beads, comprising the oxidation of the sample with strontium nitrate and its melting with lithium tetraborate, in a platinum crucib
16、le. The beads are irradiated by an X-ray beam of suitable energy. The secondary X-rays produced are dispersed by means of crystals and the corresponding intensities are measured by detectors at the selected wavelengths. The contents of the relevant elements are determined by relating the measured in
17、tensities of unknown samples to calibration curves recorded with beads prepared with certified reference materials. Fixed channel or sequential systems may be used to provide simultaneous or sequential determinations of element concentrations. PD CEN/TR 10354:2011 CEN/TR 10354:2011 (E)5 3 Reagents D
18、uring the analysis, use only reagents of recognised analytical grade. 3.1 Strontium Nitrate Sr(NO3)2 3.2 Sodium Carbonate Na2CO3 3.3 Lithium Tetraborate Li2B4O7 3.4 Sodium Iodide NaI 4 Apparatus 4.1 X-ray fluorescence spectrometer The spectrometer can be either a simultaneous or a sequential wavelen
19、gth dispersive model and shall be optimised according to the manufacturer instructions. 4.2 Melting devices 4.3 Platinum crucibles 4.4 Nickel crucibles 4.5 Platinum dishes 5 Safety precautions They shall be in accordance with national regulations for X-ray equipment. X-ray equipment shall be used on
20、ly under the guidance and supervision of a responsible, qualified person. 6 Sampling Sampling shall be carried out in accordance with appropriate international or national standards for ferro alloys. PD CEN/TR 10354:2011 CEN/TR 10354:2011 (E)6 7 Procedure 7.1 Test sample preparation In a platinum cr
21、ucible (4.3), weigh 6,00 g of Li2B4O7(3.3) to the nearest 0,001 g. In a nickel crucible (4.4), weigh, to the nearest 0,001 g: 0,750 g of Sr(NO3)2(3.1); 2,500 g of Na2CO3(3.2); 1,000 g of Li2B4O7(3.3). Then, weigh 0,250 0 g of the sample, to the nearest 0,000 1 g and add it into the same nickel cruci
22、ble (4.4). Finally transfer into the nickel crucible (4.4) 0,020 g of NaI (3.4), weighted to the nearest 0,001 g. Carefully mix all the components added into the nickel crucible (4.4) and then completely pour the mixture contained in the nickel crucible (4.4) into the platinum crucible (4.3), onto t
23、he 6,00 g of Li2B4O7(3.3), whilst avoiding the contact of the mixture with the wall of the platinum crucible (4.3). Introduce the platinum crucible (4.3) in a furnace set up at the temperature of 650 C for 6 min, in order to oxidise the sample. Melt the sample at the temperature of 1 200 C, whilst m
24、ixing continuously and then pour the melted sample in a platinum dish (4.5) preheated with a Bunsen flame. Allow the so prepared bead to cool. 7.2 Preparation of the calibration curves Prepare the calibration of the X-ray fluorescence spectrometer by using oxide beads of ferro-silicon Certified Refe
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CENTR103542011CHEMICALANALYSISOFFERROUSMATERIALSANALYSISOFFERROSILICONDETERMINATIONOFSIANDALBYXRAYFLUORESCENCESPECTROMETRY

链接地址:http://www.mydoc123.com/p-591963.html