《CEN TR 10353-2011 Chemical analysis of ferrous materials - Analysis of ferro-silicon - Determination of Al Ti and P by inductively coupled plasma optical emission spectrometry《黑色金属.pdf》由会员分享,可在线阅读,更多相关《CEN TR 10353-2011 Chemical analysis of ferrous materials - Analysis of ferro-silicon - Determination of Al Ti and P by inductively coupled plasma optical emission spectrometry《黑色金属.pdf(34页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationPD CEN/TR 10353:2011Chemical analysis of ferrousmaterials Analysis of ferro-silicon Determination of Al,Ti and P by inductively coupledplasma optical emissionspectrometryPD CEN/T
2、R 10353:2011 PUBLISHED DOCUMENTNational forewordThis Published Document is the UK implementation of CEN/TR10353:2011.The UK participation in its preparation was entrusted to TechnicalCommittee ISE/102, Methods of Chemical Analysis for Iron and Steel.A list of organizations represented on this commit
3、tee can beobtained on request to its secretary.This publication does not purport to include all the necessaryprovisions of a contract. Users are responsible for its correctapplication. BSI 2011ISBN 978 0 580 73228 7ICS 77.080.10Compliance with a British Standard cannot confer immunity fromlegal obli
4、gations.This Published Document was published under the authority of theStandards Policy and Strategy Committee on 30 November 2011.Amendments issued since publicationDate Text affectedPD CEN/TR 10353:2011TECHNICAL REPORT RAPPORT TECHNIQUE TECHNISCHER BERICHT CEN/TR 10353 November 2011 ICS 77.080.10
5、 English Version Chemical analysis of ferrous materials - Analysis of ferro-silicon - Determination of Al, Ti and P by inductively coupled plasma optical emission spectrometry Analyse chimique des matriaux ferreux - Analyse du ferro-silicium - Dtermination de Al, Ti et P par spectromtrie dmission op
6、tique avec source plasma induit Chemische Analyse von Ferrolegierungen - Analyse von Ferrosilizium - Bestimmung von Al, Ti und P durch induktiv gekoppeltes Plasma und optische EmissionsspektrometrieThis Technical Report was approved by CEN on 24 April 2011. It has been drawn up by the Technical Comm
7、ittee ECISS/TC 102. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania
8、, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2011 CEN All rights of exploitation in any form and by any means reserved wor
9、ldwide for CEN national Members. Ref. No. CEN/TR 10353:2011: EPD CEN/TR 10353:2011CEN/TR 10353:2011 (E) 2 Contents Page Foreword 3 1 Scope 4 2 Normative references 4 3 Principle 4 4 Reagents .5 5 Apparatus .6 6 Sampling .6 7 Procedure .7 8 Expression of results . 12 9 Precision 12 10 Test report . 1
10、2 Annex A (informative) Plasma optical emission spectrometer - Suggested performance criteria to be checked 13 Annex B (informative) Test samples used for the precision test 16 Annex C (informative) Detailed results obtained from the precision test 17 Bibliography . 29 PD CEN/TR 10353:2011CEN/TR 103
11、53:2011 (E) 3 Foreword This document (CEN/TR 10353:2011) has been prepared by Technical Committee ECISS/TC 102 “Methods of chemical analysis for iron and steel”, the secretariat of which is held by SIS. Attention is drawn to the possibility that some of the elements of this document may be the subje
12、ct of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. PD CEN/TR 10353:2011CEN/TR 10353:2011 (E) 4 1 Scope This Technical Report describes an inductively coupled plasma optical emission spectrometric method for the determination of Al, Ti
13、 and P contents in ferro-silicon materials. The method is applicable to: Al contents between 0,2 and 2 %; Ti contents between 0,02 and 0,25 %; P contents between 0,005 and 0,05 %. The procedure is valid for the analytical lines given in Table 1. This table also gives, for each line, the spectral int
14、erferences, which shall be corrected. NOTE The interferences extent as well as other possible interferences depend on the temperature in the plasma and on the optical resolution of the spectrometer used. Table 1 Spectral lines recommended together with the interferences which shall be corrected Elem
15、ent Wavelength (nm) Interferences Al 308,22 V Ti 337,28 V, NiP 178,29 Mo 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the reference
16、d document (including any amendments) applies. EN ISO 648, Laboratory glassware Single-volume pipettes (ISO 648:2008) EN ISO 1042, Laboratory glassware One-mark volumetric flasks (ISO 1042:1998) 3 Principle Dissolution of a test portion with nitric, hydrofluoric and perchloric acids. Addition of hyd
17、rochloric acid. Filtration and ignition of the acid insoluble residue. Fusion of the residue with sodium hydrogen sulphate, dissolution of the melt and addition of this solution to the reserved filtrate. After suitable dilution and, if necessary, addition of an internal reference element, the soluti
18、on is filtered and nebulised into an inductively coupled plasma optical emission spectrometer. The intensity of the emitted light from each element is then measured (simultaneously with that emitted from the internal reference element, where relevant). PD CEN/TR 10353:2011CEN/TR 10353:2011 (E) 5 4 R
19、eagents During the analysis, use only reagents of recognised analytical grade and only distilled water or water of equivalent purity. The same reagents should be used for the preparation of calibration solutions and of sample solutions. 4.1 Hydrofluoric acid, HF (20= 1,13 g/ml) WARNING Hydrofluoric
20、acid is extremely irritating and corrosive to skin and mucous membranes producing severe skin burns which are slow to heal. In the case of contact with skin, wash well with water, apply a topical gel containing 2,5 % (mass fraction) calcium gluconate, and seek immediate medical treatment. 4.2 Hydroc
21、hloric acid, HCl (20 = 1,19 g/ml) 4.3 Hydrochloric acid, solution 1 + 1 Add 500 ml of hydrochloric acid (4.2) to 500 ml of water. 4.4 Hydrochloric acid, solution 1 + 9 Add 50 ml of hydrochloric acid (4.2) to 450 ml of water. 4.5 Nitric acid, HNO3(20= 1,40 g/ml) 4.6 Perchloric acid, HClO4(20 = 1,68 g
22、/ml) 4.7 Sodium hydrogen sulphate 4.8 Pure iron The purity of the iron selected shall be at least ten times better than the low limit of the scope of each element included in the present method. 4.9 Aluminium, 0,5 g/l standard solution Weigh (0,5 0,001) g of aluminium (99,98 % purity) and transfer i
23、nto a 400 ml beaker. Add 50 ml of hydrochloric acid solution (4.3) and heat gently until aluminium is completely dissolved. After cooling, transfer the solution quantitatively into a 1 000 ml one-mark volumetric flask, dilute to the mark with water and mix well. 1 ml of this solution contains 0,5 mg
24、 of Al. 4.10 Titanium, 0,5 g/l standard solution Weigh (0,5 0,001) g of titanium (99,98 % purity) and transfer into a 400 ml beaker. Add 25 ml hydrochloric acid solution (4.3) and 5 to 10 drops of hydrofluoric acid (4.1). Heat gently until titanium is completely dissolved. After cooling, transfer th
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CENTR103532011CHEMICALANALYSISOFFERROUSMATERIALSANALYSISOFFERROSILICONDETERMINATIONOFALTIANDPBYINDUCTIVELYCOUPLEDPLASMAOPTICALEMISSIONSPECTROMETRY

链接地址:http://www.mydoc123.com/p-591962.html