BS EN 61300-2-46-2006 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Tests - Damp heat cyclic《纤维光学互连器件和无源元件 基本试验和测量程序 试验 湿热循环》.pdf
《BS EN 61300-2-46-2006 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Tests - Damp heat cyclic《纤维光学互连器件和无源元件 基本试验和测量程序 试验 湿热循环》.pdf》由会员分享,可在线阅读,更多相关《BS EN 61300-2-46-2006 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Tests - Damp heat cyclic《纤维光学互连器件和无源元件 基本试验和测量程序 试验 湿热循环》.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS EN61300-2-46:2006Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 2-46: Tests Damp heat cyclicICS 33.180.20nullnull nullnullnullnullnullnullnull nullnullnullnullnullnullnull nullnullnull nullnullnullnullnullnullnullnullnullnull
2、 nullnullnullnullnullnull nullnull nullnullnullnullnullnullnullnullnull nullnull nullnullnullnullnullnullnullnullnull nullnullnullIncorporatingcorrigendumOctober 2012National forewordThis British Standard is the UK implementation of EN 61300-2-46:2006. It is identical to IEC 61300-2-46:2006, incorpo
3、rating corrigendum October 2012.The UK participation in its preparation was entrusted by Technical Committee GEL/86, Fibre optics, to Subcommittee GEL/86/2, Fibre optic interconnecting devices and passive components.A list of organizations represented on this subcommittee can be obtained on request
4、to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations.BS EN 61300-2-46:2006This British Standard waspublished under t
5、he authorityof the Standards Policy andStrategy Committeeon 29 September 2006 The British StandardsInstitution 2013. Publishedby BSI Standards Limited2013Amendments/corrigenda issued since publicationDate Comments Implementation of IEC corrigendum October 2012: Clause 3 modifiedISBN 978 0 580 81181
6、430 June 2013EUROPEAN STANDARD EN 61300-2-46NORME EUROPENNE EUROPISCHE NORM August 2006 CENELEC European Committee for Electrotechnical StandardizationComit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat:rue de Stassart35, B - 1050 Brus
7、sels 2006 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELECmembers.Ref. No. EN 61300-2-46:2006 EICS 33.180.20 English version Fibre opticinterconnecting devices and passive components - Basic test and measurement procedures Part 2-46: Tests - Damp heat
8、cyclic (IEC 61300-2-46:2006)Dispositifs dinterconnexion et composants passifs fibres optiques -Mthodes fondamentales dessais et de mesures Partie 2-46: Essais - Chaleur humide, essai cyclique (CEI 61300-2-46:2006)Lichtwellenleiter -Verbindungselemente und passive Bauteile -Grundlegende Prf- und Mess
9、verfahrenTeil 2-46: Prfungen -Feuchte Wrme (zyklisch)(IEC 61300-2-46:2006)This European Standard was approved by CENELEC on 2006-08-01. CENELEC members are bound to complywith the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a nation
10、al standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained onapplication to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in a
11、ny otherlanguage made by translation under the responsibility of a CENELEC member into its own language and notifiedto the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, the Czech Republic, D
12、enmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. Foreword The text of document 86B/2304/FDIS, future edi
13、tion 1 of IEC 61300-2-46, prepared by SC 86B, Fibre optic interconnecting devices and passive components, of IEC TC 86, Fibre optics, was submitted to theIEC-CENELEC parallel vote and was approved by CENELEC as EN 61300-2-46 on 2006-08-01. The following dates were fixed: latest date by which the EN
14、has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2007-05-01 latestdate by which the national standards conflictingwith the EN have to be withdrawn (dow) 2009-08-01 Annex ZA has been added by CENELEC. _ Endorsement noticeThe textofthe In
15、ternational Standard IEC 61300-2-46:2006 was approved by CENELEC asa European Standard without any modification. _ 2 BS EN 61300-2-46:2006 EN 61300-2-46:2006 (E)CONTENTS1 Scope.42Normative reference.43General description 44Apparatus. .55Procedure. .56Severity67Details tobe specified8 3 Annex ZA (nor
16、mative) Normative references to international publications with their corresponding European publications .10BS EN 61300-2-46:2006 EN 61300-2-46:2006 (E)FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS BASIC TESTAND MEASUREMENT PROCEDURES Part 2-46: Tests Damp heat, cyclic 1 Scope The purp
17、ose of thispart of IEC 61300 is to describe a test to determine the sui tability of a fibre opticdevice to withstand the environmental condition of high humidity and change oftemperature which mayoccur in actual use, storage and/or transport. The test is primarilyintended to determine the suitabilit
18、y of fibre optic components underconditions of highhumidity -combined with cyclic temperature changes and, in general, producing condensationon the surface of the specimen.Absorptionof moi sture may resultinswelling that would destroy functional utility, cause loss ofphysical strength, and cause cha
19、nges in otherimportant mechanical properties. Degradation of optical propertiesmay also occur. Althoughnot necessarily intended as a simulated tropicaltest, th is test can, nevertheless, be useful indetermining moisture absorption of insulating or covering materials.2 Normative reference The followi
20、ng referenced documents are indispensable for the application of this document.For dated references, only the edition cited applies. For undated references, thelatesteditionof the referenced document (including any amendments)applies.IEC 60068-2-30, Environmental testing - Part 2-30: Tests Test Db:
21、Damp heat,cyclic (12 h +12 h cycle)IEC 61300-3-3, Fibre optic interconnecting devices and passive components Basic test and measurementprocedures Part 3-3: Examinations and measurements Active monitoring ofchanges in attenuation and return loss 3 Generaldescription This procedure is conducted inacco
22、rdance with IEC 60068-2-30,test Db, variant .Thespecimen is placed in achamber and subjected to a damp-heat environment which ismaintained at giventemperatures and relative humidityfor a specified duration, as specifiedin the relevant specification. 4 2BS EN 61300-2-46:2006 EN 61300-2-46:2006 (E)4 A
23、pparatus 4.1 ChamberThe apparatus consists of an environmental chamber in accordance with IEC 60068-2-30, testDb. The chamber shall be capable of housing the specimenand ofallowing access formeasurement during conditioning. It shall also be capable of maintaining the specif ied temperatures and humi
24、ditywithin the specified tolerances. Forced air circulation maybe used to maintainhomogeneous conditions. The chamberand accessories shall be constructedandarrangedin such a manner as to avoid condensation on the specimens. Water: usedistilled, demineralized or deionized water to obtain the specifie
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN613002462006FIBREOPTICINTERCONNECTINGDEVICESANDPASSIVECOMPONENTSBASICTESTANDMEASUREMENTPROCEDURESTESTSDAMPHEATCYCLIC

链接地址:http://www.mydoc123.com/p-577314.html