1、BRITISH STANDARD BS EN 60118-12:1997 IEC 60118-12: 1996 Hearing aids Part 12: Dimensions of electrical connector systems The European Standard EN 60118-12:1996 has the status of a British Standard ICS 17.140.50BSEN60118-12:1997 This British Standard, having been prepared under the directionof the El
2、ectrotechnical Sector Board, was published underthe authority of the Standards Board and comes into effect on 15 September 1997 BSI 09-1999 ISBN 0 580 27795 X National foreword This British Standard is the English language version of EN 60118-12:1996. It is identical with IEC 60118-12:1996. It super
3、sedes BS 2813 Specification for dimensions of plugs for hearing aids: 1981 which will be withdrawn on 1997-07-01. The UK participation in its preparation was entrusted to Technical Committee EPL/29, Electroacoustics, which has the responsibility to: aid enquirers to understand the text; present to t
4、he responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. A list of organizations represented on this committee can be obtain
5、ed on request to its secretary. From 1 January 1997, all IEC publications have the number 60000 added to the old number. For instance, IEC 27-1 has been renumbered as IEC 60027-1. For a period of time during the change over from one numbering system to the other, publications may contain identifiers
6、 from both systems. Cross-references Attention is drawn to the fact that CEN and CENELEC Standards normally include an annex which lists normative references to international publications with their corresponding European publications. The British Standards which implement these international or Eur
7、opean publications may be found in the BSI Standards Catalogue under the section entitled “International Standards Correspondence Index”, or using the “Find” facility of the BSI Standards Electronic Catalogue. A British Standard does not purport to include all the necessary provisions of a contract.
8、 Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, theEN title page, pages 2 to 16 and
9、a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover. Amendments issued since publications Amd. No. Date CommentsBSEN60118-12:1997 BSI 09-1999 i Contents Page National forew
10、ord Inside front cover Foreword 2 Text of EN 60118-12 3ii blankEUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 60118-12 October 1996 ICS 17.140.50; 31.220.10 Supersedes HD 304 S1:1977 Descriptors: Electroacoustics, hearing aids, junctions, dimensions, interchangeability English version Hearing
11、aids Part 12: Dimensions of electrical connector systems (IEC 118-12:1996) Appareils de correction auditive Partie 12: Dimensions des connecteurs lectriques (CEI 118-12:1996) Hrgerte Teil 12: Mae elektrischer Steckverbindersysteme (IEC 118-12:1996) This European Standard was approved by CENELEC on 1
12、996-10-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may b
13、e obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to th
14、e Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United K
15、ingdom. CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B-1050 Brussels 1996 Copyright reserved to CENELEC members Ref. No. EN 60118-12:1996 EEN60
16、118-12:1996 BSI 09-1999 2 Foreword The text of document 29/330/FDIS, future edition 1 of IEC 118-12, prepared by IEC TC 29, Electroacoustics, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 60118-12 on 1996-10-01. This European Standard supersedes HD304S1:1977. The f
17、ollowing dates were fixed: Endorsement notice The text of the International Standard IEC 118-12:1996 was approved by CENELEC as a European Standard without any modification. Contents Page Foreword 2 1 Scope 3 2 Overview of connector systems 3 Annex A (informative) Recommended use ofcircularconnector
18、systems 16 Figure 1 Two-terminal polarized plug forearphones 7 Figure 2 Three-terminal unpolarized plugforearphones 8 Figure 3 Three-terminal polarized plugforelectrical input 9 Figure 4 Three-terminal plug 10 Figure 5 Four-terminal plug 11 Figure 6 Five-terminal plug 12 Figure 7 Three-terminal sock
19、et 13 Figure 8 Four-terminal socket 14 Figure 9 Five-terminal socket 15 Table 1 Overview of connector systems 3 Table 2 Dimensions of plugs shown in Figure 1,Figure 2and Figure 3 4 Table 3 Dimensions of plugs shown in Figure 4,Figure 5and Figure 6 5 Table 4 Dimensions of sockets shown in Figure 7, F
20、igure 8 and Figure 9 6 latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 1997-07-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 1997-07-01EN60118-12:1996 BSI
21、09-1999 3 1 Scope This International Standard applies to plugs and connector systems for hearing aids and specifies the dimensions and their tolerances essential for ensuring interchangeability. 2 Overview of connector systems Table 1 Overview of connector systems System Application Dimensions (see
22、table) Figure Rectangular connector system Two-terminal polarized plug Earphones Table 2 Figure 1 Three-terminal unpolarized plug Earphones Table 2 Figure 2 Three-terminal polarized plug Electrical input Table 2 Figure 3 Circular connector system Three-terminal plug See Annex A Table 3 Figure 4 Thre
23、e-terminal socket See Annex A Table 4 Figure 7 Four-terminal plug See Annex A Table 3 Figure 5 Four-terminal socket See Annex A Table 4 Figure 8 Five-terminal plug See Annex A Table 3 Figure 6 Five-terminal socket See Annex A Table 4 Figure 9EN60118-12:1996 4 BSI 09-1999 Table 2 Dimensions of plugs
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN60118121997HEARINGAIDSDIMENSIONSOFELECTRICALCONNECTORSYSTEMS 助听器 12 部分 连接器 系统 尺寸 PDF

链接地址:http://www.mydoc123.com/p-575314.html