BS EN 50600-2-3-2014 Information technology Data centre facilities and infrastructures Environmental control《信息技术 数据中心设施和基础设施 环境控制》.pdf
《BS EN 50600-2-3-2014 Information technology Data centre facilities and infrastructures Environmental control《信息技术 数据中心设施和基础设施 环境控制》.pdf》由会员分享,可在线阅读,更多相关《BS EN 50600-2-3-2014 Information technology Data centre facilities and infrastructures Environmental control《信息技术 数据中心设施和基础设施 环境控制》.pdf(32页珍藏版)》请在麦多课文档分享上搜索。
1、BSI Standards PublicationBS EN 50600-2-3:2014Information technology Data centre facilities andinfrastructuresPart 2-3: Environmental controlBS EN 50600-2-3:2014 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN50600-2-3:2014.The UK participation in its preparation
2、 was entrusted to TechnicalCommittee TCT/7, Telecommunications - Installation requirements.A list of organizations represented on this committee can beobtained on request to its secretary.This publication does not purport to include all the necessaryprovisions of a contract. Users are responsible fo
3、r its correctapplication. The British Standards Institution 2014. Published by BSI StandardsLimited 2014ISBN 978 0 580 81135 7ICS 35.020; 35.110; 35.160Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStanda
4、rds Policy and Strategy Committee on 31 October 2014.Amendments issued since publicationDate Text affectedBS EN 50600-2-3:2014EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 50600-2-3 October 2014 ICS 35.020; 35.110; 35.160 English Version Information technology - Data centre facilities and inf
5、rastructures - Part 2-3: Environmental control Technologie de linformation - Installation et infrastructures des centres de traitement de donnes - Partie 2-3: Contrle environnemental Informationstechnik - Einrichtungen und Infrastrukturen von Rechenzentren - Teil 2-3: berwachung der Umgebung This Eu
6、ropean Standard was approved by CENELEC on 2014-09-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.Up-to-date lists and bibliographical referenc
7、es concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CE
8、NELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugosl
9、av Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. European Committee for Electrotechnical Standa
10、rdization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2014 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members. Ref. No. EN 50600-2
11、-3:2014 EBS EN 50600-2-3:2014EN 50600-2-3:2014 2 Contents Page Foreword . 4 Introduction . 5 1 Scope . 7 2 Normative references. 7 3 Terms, definitions and abbreviations 7 3.1 Terms and definitions . 7 3.2 Abbreviations 9 4 Conformance 9 5 Environmental control within data centres . 9 5.1 General .
12、9 5.2 Environmental control of data centre spaces . 10 6 Availability 14 6.1 General . 14 6.2 Design options by space . 14 6.3 Environmental control system capacity planning with respect to expansion 18 6.4 Environmental control system capacity planning with respect to resilience . 18 7 Physical sec
13、urity 18 7.1 General . 18 7.2 Access 18 8 Energy efficiency enablement 18 8.1 General . 18 8.2 Measurement of temperature . 19 8.3 Measurement of relative humidity . 20 8.4 Measurement of air pressure 21 8.5 Coolant flow rates . 21 8.6 Heat removal 21 8.7 Outside air. 22 8.8 Provision of alarms . 22
14、 8.9 Measurement requirements by Granularity Level. 22 Annex A (normative) Distribution methodologies for temperature-controlled air in computer room space . 23 A.1 Cabinet or rack air flow management 23 A.2 Access floor air flow management . 23 A.3 Hot aisles/cold aisles . 24 Annex B (informative)
15、Control system concepts . 26 B.1 General 26 B.2 Control of exhaust temperature (return air) 26 B.3 Control of supply temperature (supply air) . 26 BS EN 50600-2-3:2014 3 EN 50600-2-3:2014 B.4 Combination of control of supply and exhaust temperature 26 B.5 Supply air relative humidity 26 B.6 Proporti
16、on of outside air . 26 Bibliography 27 BS EN 50600-2-3:2014EN 50600-2-3:2014 4 Foreword This document (EN 50600-2-3:2014) has been prepared by CLC/TC 215 “Electrotechnical aspects of telecommunication equipment”. The following dates are fixed: latest date by which this document has to be implemented
17、 at national level by publication of an identical national standard or by endorsement (dop) 2015-09-01 latest date by which the national standards conflicting with this document have to be withdrawn (dow) 2017-09-01 Attention is drawn to the possibility that some of the elements of this document may
18、 be the subject of patent rights. CENELEC shall not be held responsible for identifying any or all such patent rights. This document has been prepared under a mandate given to CENELEC by the European Commission and the European Free Trade Association. BS EN 50600-2-3:2014 5 EN 50600-2-3:2014 Introdu
19、ction The unrestricted access to internet-based information demanded by the information society has led to an exponential growth of both internet traffic and the volume of stored/retrieved data. Data centres are housing and supporting the information technology and network telecommunications equipme
20、nt for data processing, data storage and data transport. They are required both by network operators (delivering those services to customer premises) and by enterprises within those customer premises. Data centres need to provide modular, scalable and flexible facilities and infrastructures to easil
21、y accommodate the rapidly changing requirements of the market. In addition, energy consumption of data centres has become critical both from an environmental point of view (reduction of carbon footprint) and with respect to economical considerations (cost of energy) for the data centre operator. The
22、 implementation of data centres varies in terms of: a) purpose (enterprise, co-location, co-hosting or network operator facilities); b) security level; c) physical size; d) accommodation (mobile, temporary and permanent constructions). The needs of data centres also vary in terms of availability of
23、service, the provision of security and the objectives for energy efficiency. These needs and objectives influence the design of data centres in terms of building construction, power distribution, environmental control and physical security. Effective management and operational information is require
24、d to monitor achievement of the defined needs and objectives. This series of European Standards specifies requirements and recommendations to support the various parties involved in the design, planning, procurement, integration, installation, operation and maintenance of facilities and infrastructu
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN50600232014INFORMATIONTECHNOLOGYDATACENTREFACILITIESANDINFRASTRUCTURESENVIRONMENTALCONTROL 信息技术 数据中心

链接地址:http://www.mydoc123.com/p-575065.html