BS EN 1822-4-2009 High efficiency air filters (EPA HEPA and ULPA) - Determining leakage of filter elements (scan method)《高效空气过滤器(EPA HEPA和ULPA) 过滤元件泄漏性测定(扫描法)》.pdf
《BS EN 1822-4-2009 High efficiency air filters (EPA HEPA and ULPA) - Determining leakage of filter elements (scan method)《高效空气过滤器(EPA HEPA和ULPA) 过滤元件泄漏性测定(扫描法)》.pdf》由会员分享,可在线阅读,更多相关《BS EN 1822-4-2009 High efficiency air filters (EPA HEPA and ULPA) - Determining leakage of filter elements (scan method)《高效空气过滤器(EPA HEPA和ULPA) 过滤元件泄漏性测定(扫描法)》.pdf(46页珍藏版)》请在麦多课文档分享上搜索。
1、BS EN1822-4:2009ICS 13.040.40; 23.120NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBRITISH STANDARDHigh efficiency airfilters (EPA, HEPA andULPA)Part 4: Determining leakage of filterelements (scan method)Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 18/03/2010 03:20,
2、 Uncontrolled Copy, (c) BSIThis British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 January2010 BSI 2010ISBN 978 0 580 61793 5Amendments/corrigenda issued since publicationDate CommentsBS EN 1822-4:2009National forewordThis British Standard is the
3、UK implementation of EN 1822-4:2009. It supersedes BS EN 1822-4:2000 which is withdrawn.The UK participation in its preparation was entrusted to Technical Committee MCE/21/3, Air filters other than for air supply for I.C. engines and compressors.A list of organizations represented on this committee
4、can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations.Licensed Copy: Wang Bin, ISO/EXCHANG
5、E CHINA STANDARDS, 18/03/2010 03:20, Uncontrolled Copy, (c) BSIBS EN 1822-4:2009EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 1822-4 November 2009 ICS 13.040.40 Supersedes EN 1822-4:2000English Version High efficiency air filters (EPA, HEPA and ULPA) - Part 4: Determining leakage of filter el
6、ements (scan method) Filtres air haute efficacit (EPA, HEPA et ULPA) - Partie 4: Essais dtanchit de llment filtrant (mthode dexploration) Schwebstofffilter (EPA, HEPA und ULPA) - Teil 4: Leckprfung des Filterelementes (Scan-Verfahren) This European Standard was approved by CEN on 17 October 2009. CE
7、N members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on app
8、lication to the CEN Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre
9、 has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland,
10、 Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2009 CEN All rights of exploitation in any form and by any
11、means reserved worldwide for CEN national Members. Ref. No. EN 1822-4:2009: ELicensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 18/03/2010 03:20, Uncontrolled Copy, (c) BSIBS EN 1822-4:2009EN 1822-4:2009 (E) 2 Contents Page Foreword 4Introduction 51 Scope .62 Normative references .63 Terms and d
12、efinitions 64 Description of the procedure 75 Test filter 86 Test apparatus 86.1 Set-up of the test apparatus 86.2 Test duct . 116.2.1 Test air conditioning . 116.2.2 Adjustment of the volume flow rate . 116.2.3 Measurement of the volume flow rate . 116.2.4 Aerosol mixing duct 116.2.5 Test filter mo
13、unting assembly 116.2.6 Measuring points for the pressure difference 116.2.7 Sampling, upstream 116.2.8 Screening . 126.3 Scanning assembly . 126.3.1 General . 126.3.2 Sampling, downstream . 126.3.3 Probe arm . 136.3.4 Aerosol transport lines . 136.3.5 Provisions to move the probe 136.4 Aerosol gene
14、ration and measurement techniques 136.4.1 General . 136.4.2 Set-up for testing with a monodisperse test aerosol . 146.4.3 Set-up for testing with a polydisperse test aerosol . 147 Test air 148 Test procedure . 158.1 General . 158.2 Preparatory checks . 158.3 Starting up the aerosol generator 168.4 P
15、reparing the test filter . 168.4.1 Installing the test filter 168.4.2 Flushing the test filter . 168.5 Testing 168.5.1 Measuring the pressure drop . 168.5.2 Testing with monodisperse test aerosol . 178.5.3 Testing with polydisperse test aerosol . 178.5.4 Leak testing (local penetration) . 178.5.5 De
16、termining the mean efficiency of the filter element . 179 Evaluation . 189.1 Calculating the penetration and the efficiency . 189.2 Local penetration . 199.3 Mean efficiency 20Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 18/03/2010 03:20, Uncontrolled Copy, (c) BSIBS EN 1822-4:2009EN 1822-
17、4:2009 (E) 3 9.4 Classification 2010 Test report . 2011 Maintenance and inspection of the test apparatus . 21Annex A (normative) Oil Thread Leak Test . 23Annex B (normative) Determining the test parameters . 24B.1 General 24B.2 Boundary conditions 24B.3 Test filter data . 24B.4 Data for the apparatu
18、s . 25B.4.1 Particle counters 25B.4.2 Downstream sampling probes 25B.4.3 Loss factor 26B.5 Sequence of calculation steps 26B.6 Checking the isokinetic sampling 27B.7 Choosing the probe speed 28B.8 Minimum aerosol concentration . 29B.9 Maximum aerosol concentration 30B.10 Leak signal 31B.10.1 Effecti
19、ve value 31B.10.2 Signal difference . 32Annex C (informative) Example of an application with evaluation . 34Annex D (informative) Leak Test with solid PSL Aerosol 37D.1 Background . 37D.2 General Remarks 37D.3 Test Procedure . 37D.4 Test Protocol . 39Annex E (informative) 0,3 m 0,5 m Particle Effici
20、ency Leak Test 40Bibliography . 42Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 18/03/2010 03:20, Uncontrolled Copy, (c) BSIBS EN 1822-4:2009EN 1822-4:2009 (E) 4 Foreword This document (EN 1822-4:2009) has been prepared by Technical Committee CEN/TC 195 “Air filters for general air cleaning
21、”, the secretariat of which is held by UNI. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by May 2010, and conflicting national standards shall be withdrawn at the latest by May 2010. Attention is
22、drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 1822-4:2000. It contains requirements, fundamental principles of testin
23、g and the marking for efficient particulate air filters (EPA), high efficiency particulate air filters (HEPA) and ultra low penetration air filters (ULPA). The complete European Standard EN 1822, High efficiency air filters (EPA, HEPA and ULPA) will consist of the following parts: Part 1: Classifica
24、tion, performance testing, marking Part 2: Aerosol production, measuring equipment, particle counting statistics Part 3: Testing flat sheet filter media Part 4: Determining leakage of filter elements (scan method) Part 5 : Determining the efficiency of filter elements According to the CEN/CENELEC In
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN182242009HIGHEFFICIENCYAIRFILTERSEPAHEPAANDULPADETERMININGLEAKAGEOFFILTERELEMENTSSCANMETHOD 高效 空气

链接地址:http://www.mydoc123.com/p-549332.html