《BS DD CLC TS 50429-2005 Optical fibre cables Sewer cables Family specification for cables to be installed in storm and sanitary sewers《光缆 地下电缆 安装在雨水道和卫生间下水道的光缆的系列规范》.pdf》由会员分享,可在线阅读,更多相关《BS DD CLC TS 50429-2005 Optical fibre cables Sewer cables Family specification for cables to be installed in storm and sanitary sewers《光缆 地下电缆 安装在雨水道和卫生间下水道的光缆的系列规范》.pdf(38页珍藏版)》请在麦多课文档分享上搜索。
1、DRAFT FOR DEVELOPMENT DD CLC/TS 50429:2005 Optical fibre cables Sewer cables Family specification for cables to be installed in storm and sanitary sewers ICS 33.180.10 DD CLC/TS 50429:2005 This Draft for Development was published under the authority of the Standards Policy and Strategy Committee on
2、23 February 2005 BSI 23 February 2005 ISBN 0 580 45566 1 National foreword This Draft for Development is the official English language version of CLC/TS 50429:2005. This publication is not to be regarded as a British Standard. It is being issued in the Draft for Development series of publications an
3、d is of a provisional nature because the technology is still at a developmental stage. It should be applied on this provisional basis, so that information and experience of its practical application may be obtained. Comments arising from the use of this Draft for Development are requested so that UK
4、 experience can be reported to the European organization responsible for its conversion to a European Standard. A review of this publication will be initiated 2 years after its publication by the European organization so that a decision can be taken on its status at the end of its 3-year life. Notif
5、ication of the start of the review period will be made in an announcement in the appropriate issue of Update Standards. According to the replies received by the end of the review period, the responsible BSI Committee will decide whether to support the conversion into a European Standard, to extend t
6、he life of the Technical Specification or to withdraw it. Comments should be sent in writing to the Secretary of BSI Subcommittee GEL/86/1, Optical fibres and cables, at 389 Chiswick High Road, London W4 4AL, giving the document reference and clause number and proposing, where possible, an appropria
7、te revision of the text. A list of organizations represented on this subcommittee can be obtained on request to its secretary. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Catalogue under the sectio
8、n entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online. Summary of pages This document comprises a front cover, an inside front cover, the CLC/TS title page, pages 2 to 35 and a back cover. The BSI c
9、opyright notice displayed in this document indicates when the document was last issued. Amendments issued since publication Amd. No. Date CommentsTECHNICAL SPECIFICATION CLC/TS 50429 SPECIFICATION TECHNIQUE TECHNISCHE SPEZIFIKATION February 2005 CENELEC European Committee for Electrotechnical Standa
10、rdization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2005 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. CLC/TS 50429:2
11、005 E ICS 33.180.10 English version Optical fibre cables Sewer cables Family specification for cables to be installed in storm and sanitary sewers Lichtwellenleiterkabel Kabel fr Abwasserkanle Familienspezifikation fr Kabel zu Montage in Abwasserkanlen This Technical Specification was approved by CE
12、NELEC on 2004-09-11. CENELEC members are required to announce the existence of this TS in the same way as for an EN and to make the TS available promptly at national level in an appropriate form. It is permissible to keep conflicting national standards in force. CENELEC members are the national elec
13、trotechnical committees of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. C
14、LC/TS 50429:2005 - 2 - Foreword This Technical Specification was prepared by the Technical Committee CENELEC TC 86A, Optical fibres and optical fibre cables. The text of the draft was submitted to the vote and was approved by CENELEC as CLC/TS 50429 on 2004-09-11. The following date was fixed: lates
15、t date by which the existence of the CLC/TS has to be announced at national level (doa) 2005-03-11 _ - 3 - CLC/TS 50429:2005 Contents 1 Scope 5 2 Normative references5 3 Symbols 6 4 Family specification for sewer cables and conduits for installation by blowing and/or pulling in sewers (blank detail
16、specification and minimum requirements) 7 4.1 Construction7 4.1.1 General. 7 4.1.2 Conduits 7 4.1.3 Sewer cables7 4.1.4 Rodent protection 8 4.2 Product descriptions 8 4.2.1 Sewer cables description 8 4.2.1.1 Cable for installation within conduits (previously fixed to the sewer wall). 8 4.2.1.2 Cable
17、s for direct installation into the sewer duct 9 4.2.2 Conduit description . 10 4.3 Optical fibres.11 4.3.1 Single-mode dispersion unshifted (B1.1) optical fibre 11 4.3.2 Single mode dispersion shifted (B2) optical fibre. 11 4.3.3 Single mode non-zero dispersion (B4) optical fibre . 11 4.3.4 Multimod
18、e fibres 12 4.4 Sewer cable constructions 12 4.4.1 Cable for insallation within conduits (previously fixed to the sewer wall) 12 4.4.2 Cable for direct installation into the sewer duct . 13 4.4.3 Conduit construction . 14 4.5 Installation and operating conditions . 14 4.5.1 Tests applicable14 4.5.2
19、Installation conditions 15 4.6 Mechanical and environmental tests . 15 4.6.1 Conduit . 15 4.6.1.1 Tests applicable15 4.6.1.2 Details of family requirements and test conditions for conduits . 16 4.6.1.2.1 Pressure.16 4.6.1.2.2 Tensile performance.16 4.6.1.2.3 Kink.16 4.6.1.2.4 Crush17 4.6.1.2.5 Impac
20、t.17 4.6.1.2.6 Flexibility.17 4.6.2 Cable for installation within conduits (previously fixed to the sewer wall). 18 4.6.2.1 Tests applicable18 4.6.2.2 Details of family requirements and test conditions for sewer cable tests . 19 4.6.2.2.1 Tensile performance.19 4.6.2.2.2 Repeated bending. 19 4.6.2.2
21、.3 Torsion20 4.6.2.2.4 Bend.20 4.6.2.2.5 Crush20 CLC/TS 50429:2005 - 4 - 4.6.2.2.6 Impact.21 4.6.2.2.7 Temperature cycling21 4.6.2.3 Details of family requirements and test conditions for blowing performance of sewer cables to be installed in conduits 22 4.6.3 Cables for direct installation into the
22、 sewer duct 23 4.6.3.1 Test applicable23 4.6.3.2 Details of family requirements and test conditions for sewer cables 24 4.6.3.2.1 Tensile performance.24 4.6.3.2.2 Repeated bending. 24 4.6.3.2.3 Torsion25 4.6.3.2.4 Bend . 25 4.6.3.2.5 Crush25 4.6.3.2.6 Impact.26 4.6.3.2.7 Temperature cycling26 4.7 Ex
23、amples of conduits and sewer cables 27 4.7.1 Cables for installation within conduits 27 4.7.1.1 Dielectric sewer cables . 27 4.7.1.2 Sewer cable installed within a conduit. 28 4.7.2 Cables for direct installation into the sewer duct 29 4.7.2.1 Cables to be screwed to the sewer inner wall 29 4.7.2.2
24、Cables for spanning between manholes, similarly to aerial cables 30 4.7.2.3 Cables for laying on the ground of the sewer 31 4.8 Examples of installation schemes . 32 4.8.1 Installation within conduits. 32 4.8.1.1 Conduit robotized installation 32 4.8.1.2 Spring loaded stainless-steel ring 33 4.8.2 I
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSDDCLCTS504292005OPTICALFIBRECABLESSEWERCABLESFAMILYSPECIFICATIONFORCABLESTOBEINSTALLEDINSTORMANDSANITARYSEWERS

链接地址:http://www.mydoc123.com/p-548195.html