BS AU 267-1998 Code of practice for breakaway cables and secondary couplings《断开式电缆和二次耦合的实用规程》.pdf
《BS AU 267-1998 Code of practice for breakaway cables and secondary couplings《断开式电缆和二次耦合的实用规程》.pdf》由会员分享,可在线阅读,更多相关《BS AU 267-1998 Code of practice for breakaway cables and secondary couplings《断开式电缆和二次耦合的实用规程》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | BRITISH STANDARD AUTOMOBILE SERIES BS AU 2
2、67:1998 ICS 43.040.70; 43.100 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW Code of practice for Breakaway cables and secondary couplingsThis British Standard, having been prepared under the direction of the Engineering Sector Board, was published under the authority of the
3、Standards Board and comes into effect on 15 November 1998 BSI 1998 The following BSI references relate to the work on this standard: Committee reference AUE/8 Draft for comment 96/715576 DC ISBN 0 580 28203 1 BS AU 267:1998 Amendments issued since publication Amd. No. Date Text affected Committees r
4、esponsible for this British Standard The preparation of this British Standard was entrusted to Technical Committee AUE/8, Undergear for caravans and trailers, upon which the following bodies were represented: Caravan Club Department of the Environment, Transport and the Regions National Caravan Coun
5、cil Limited National Trailer and Towing Association Ltd. Society of Motor Manufacturers and Traders LimitedBS AU 267:1998 BSI 1998 i Contents Page Committees responsible Inside front cover Foreword ii 1 Scope 1 2 Terms and definitions 1 3 Application 1 4 Design 1 5 Attachment 1 6 General 2 7 Trailer
6、 documentation 2 Figure 1 Direction of test load application 2ii BSI 1998 BS AU 267:1998 Foreword This British Standard has been prepared by Technical Committee AUE/8. As a code of practice, this British Standard takes the form of guidance and recommendations. It should not be quoted as if it were a
7、 specification and particular care should be taken to ensure that claims of compliance are not misleading. EEC Directive 71/320/EEC, Braking requirements and EEC Regulation No. 13, requires the fitting of a breakaway cable or secondary coupling on all trailers up to a maximum gross weight of 3500 kg
8、. It is now also a requirement of the Construction and Use Regulations that such a device is positively attached to a towing vehicle. A British Standard does not purport to include all necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compl
9、iance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, pages 1 and 2, an inside back cover and a back cover. BSI 1998 1 BS AU 267:1998 1 Scope This code of practice provid
10、es recommendations for breakaway cables and secondary couplings, and their attachment points, for light trailers or caravans up to a mass of 3 500 kg. It applies to trailers which do not have brakes or have overrun or inertia type braking systems only. 2 Terms and definitions 2.1 breakaway cable cab
11、le between the towing vehicle and the trailer including its fitments which, in the event of separation of the main coupling, activates the braking mechanism of the trailer 2.2 secondary coupling coupling device between the trailer and towing vehicle which, upon separation of the main coupling, ensur
12、es that the two vehicles remain connected, prevents the nose of the drawbar touching the ground and provides residual steering for the trailer 2.3 attachment point fitting (e.g. closed hole, loop or eyelet) provided for the attachment of a breakaway cable or secondary coupling to the towing vehicle
13、2.4 coupling device, usually made in two parts, which connects the trailer to the towing vehicle NOTE It allows for movement, in all axes, of the two vehicles and withstands the applied static and dynamic loads during loading and operation. Typical examples are a coupling head and towball or towing
14、eye and jaw. 3 Application Trailers with a mass of up to 3 500 kg should be fitted with either a breakaway cable or a secondary coupling. Trailers without brakes should have a maximum mass of 750 kg and should be fitted with a secondary coupling. It is recommended that trailers with brakes should be
15、 fitted with a breakaway cable. 4 Design 4.1 Breakaway cable The breakaway cable should be capable of applying a sufficient load to the braking system operating mechanism to hold the trailer on at least 18 % gradient at its maximum permissible trailer mass. Upon operation of the breakaway cable, the
16、 trailer should be brought to a halt without causing damage to the braking system components as a result of the application of too great an operating force. The breakaway cable should part after application of the trailer brakes either by reason of its ultimate strength or by means of a weak link in
17、serted for this purpose. The cable should be provided with a device capable of permitting attachment to the attachment point and withstanding the applied loads without failure unless it provides the stress limit feature. The breakaway cable should have sufficient length to enable attachment to be ma
18、de with the vehicle in any normal towing position without risk of inadvertent brake application or coming into contact with the ground. In order to ensure the compatibility of the breakaway cable with the braking system only the trailer manufacturers original equipment cable or equivalent should be
19、used. 4.2 Secondary couplings Secondary couplings used for the retention of trailers in the event of main coupling separation should be designed to have an ultimate tensile strength of equivalent to at least twice the maximum permissible mass of the trailer. 5 Attachment 5.1 General The breakaway ca
20、ble or secondary coupling should be attached to the towbar in accordance with 5.2 or 5.3. NOTE The preferred method is by direct attachment, see 5.2. 5.2 Direct attachment The sprung hook or clip on the end of the breakaway cable or secondary coupling should be attached directly to, or through, an a
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSAU2671998CODEOFPRACTICEFORBREAKAWAYCABLESANDSECONDARYCOUPLINGS 断开 电缆 二次 耦合 实用 规程 PDF

链接地址:http://www.mydoc123.com/p-547827.html