BS 7870-3 40-2011 LV and MV polymeric insulated cables for use by distribution and generation utilities Specification for distribution cables of rated voltage 0 6 1 kV XLPE insulat.pdf
《BS 7870-3 40-2011 LV and MV polymeric insulated cables for use by distribution and generation utilities Specification for distribution cables of rated voltage 0 6 1 kV XLPE insulat.pdf》由会员分享,可在线阅读,更多相关《BS 7870-3 40-2011 LV and MV polymeric insulated cables for use by distribution and generation utilities Specification for distribution cables of rated voltage 0 6 1 kV XLPE insulat.pdf(20页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS 7870-3.40:2011Incorporating Corrigendum No. 1LV and MV polymericinsulated cables for use bydistribution and generationutilitiesPart 3: Specification for distributioncables of
2、rated voltage 0.6/1 kVSection 3.40: XLPE insulated, copperwire waveform concentric cableswith solid aluminium conductors(Implementation of HD 603)Publishing and copyright informationThe BSI copyright notice displayed in this document indicates when the documentwas last issued. The British Standards
3、Institution 2012Published by BSI Standards Limited 2012ISBN 978 0 580 78838 3ICS 29.060.20The following BSI references relate to the work on this standard:Committee reference GEL/20/16Draft for comment 11/30214068 DCPublication historyBS 7870-3.4 first published December 1996First published as BS 78
4、70-3.40 (revision of BS 7870-3.4), September 2001Second (present) edition, December 2011Amendments issued since publicationDate Text affectedAugust 2012 See forewordBS 7870-3.40:2011 BRITISH STANDARDContentsForeword ii1 Scope 12 Normative references 13 Voltage designation 14 Core conductors 15 Insul
5、ation 26 Assembly of cores 27 Concentric conductor 28 Oversheath 39 Marking 310 End sealing 411 Dimensions 512 Tests 613 Routine tests 714 Sample tests 715 Type tests 8AnnexesAnnex A (informative) Guide to selection and use of cables 10Bibliography 11List of tablesTable 1 3-core, 3-phase cables 5Tab
6、le 2 4-core, 3-phase cables 5Table 3 Schedule of tests 6Table 4 Requirements for compatibility of insulation, oversheath and rubberlayer 9Table A.1 Guide to use 10Summary of pagesThis document comprises a front cover, an inside front cover, pages i to iv,pages 1 to 12, an inside back cover and a bac
7、k cover.BRITISH STANDARD BS 7870-3.40:2011 The British Standards Institution 2012 iForewordPublishing informationThis section of BS 7870 is published by BSI Standards Limited, under licence fromThe British Standards Institution, and came into effect on 31 December 2011. Itwas prepared by Subcommitte
8、e GEL/20/16, Medium/High voltage cables, underthe authority of Technical Committee GEL/20, Electric cables. A list oforganizations represented on these committees can be obtained on request totheir secretary.SupersessionThis section of BS 7870 supersedes BS 7870-3.40:2001, which is withdrawn.Relatio
9、nship with other publicationsBS 7870 implements the nationally applicable parts of Harmonization DocumentsHD 603, 605, 620, 626 and 627 published by the European Committee forElectrotechnical Standardization (CENELEC) in accordance with the decision ofthe CENELEC Technical Board.BS 7870 applies to c
10、ables for fixed installations having a rated voltage U0/U upto and including 19/33 kV, and is published as a series of separate parts andsections, as listed in the table in the foreword of BS 7870-1.BS 7870-3.40 specifies a range of XLPE insulated, copper wire waveformconcentric cables with solid al
11、uminium conductors; it implements Part 5R ofHD 603 S1 A2, and is to be read in conjunction with BS 7870-1 and BS 7870-2.Information about this documentThis is a full revision of the standard, and brings the standard up to date inaccordance with current practice in the industry.The start and finish o
12、f text introduced or altered by Corrigendum No. 1 isindicated in the text by tagsand.A general guide to use for the types of cable specified in BS 7870 is given inBS 7870-1 and specific details for the types of cable specified in this section ofBS 7870 are given in Annex A.Hazard warningsWARNING. Th
13、is British Standard calls for the use of substances and/orprocedures that can be injurious to health if adequate precautions are nottaken. It refers only to technical suitability and does not absolve the userfrom legal obligations relating to health and safety at any stage.Use of this documentIt has
14、 been assumed in the preparation of this British Standard that theexecution of its provisions will be entrusted to appropriately qualified andexperienced people, for whose use it has been produced.Presentational conventionsThe provisions of this standard are presented in roman (i.e. upright) type. I
15、tsrequirements are expressed in sentences in which the principal auxiliary verb is“shall”.Commentary, explanation and general informative material is presented insmaller italic type, and does not constitute a normative element.BRITISH STANDARDBS 7870-3.40:2011ii The British Standards Institution 201
16、2Contractual and legal considerationsThis publication does not purport to include all the necessary provisions of acontract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legalobligations.BRITISH STANDARD BS 7870-3.40:2011 The Britis
17、h Standards Institution 2012 iiiBRITISH STANDARDBS 7870-3.40:2011This page deliberately left blankiv The British Standards Institution 20121 ScopeThis section of BS 7870 specifies requirements for the construction, dimensionsand mechanical and electrical properties of copper wire waveform cables wit
18、hsolid aluminium core conductors, XLPE insulation and PVC oversheath having arated voltage of 0.6/1(1.2) kV.It specifies requirements for the following types of cable:a) 3-core, 3-phase, with a concentric neutral/earth conductor of copper wiresbedded on a single rubber layer;b) 4-core, 3-phase and a
19、 separate neutral, with a concentric earth conductor ofcopper wires bedded on a single rubber layer.This section of BS 7870 is applicable to cables that are designed for a maximumcontinuous conductor operating temperature of 80 C and for a maximum shortcircuit conductor temperature of 250 C.2 Normat
20、ive referencesThe following referenced documents are indispensable for the application ofthis document. For dated references, only the edition cited applies. For undatedreferences, the latest edition of the referenced document (including anyamendments) applies.BS 3988:1970+A3:1989, Specification for
21、 wrought aluminium for electricalpurposes Solid conductors for insulated cablesBS 7870-1, LV and MV polymeric insulated cables for use by distribution andgeneration utilities Part 1: GeneralBS 7870-2, LV and MV polymeric insulated cables for use by distribution andgeneration utilities Part 2: Method
22、s of testBS EN 60228, Specification for conductors in insulated cables and cordsBS EN 60811-1-2, Insulating and sheathing materials of electric cables Commontest methods Part 1-2: General application Thermal ageing methodsBS EN 60811-1-3, Insulating and sheathing materials of electric cables Commont
23、est methods Part 1-3: General application Methods for determining thedensity Water absorption tests Shrinkage test3 Voltage designationCables shall be designated by the voltages U0, U and Um, expressed in the formU0/U (Um).The voltage designation of cables in this standard shall be 0.6/1(1.2) kV.The
24、 rated voltage of the cable shall be at least equal to the nominal voltage ofthe system for which it is intended.4 Core conductorsThe core conductors shall be circular or shaped solid aluminium in accordancewith Table 1 or Table 2, as applicable, and shall conform to the requirements forsolid conduc
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS78703402011LVANDMVPOLYMERICINSULATEDCABLESFORUSEBYDISTRIBUTIONANDGENERATIONUTILITIESSPECIFICATIONFORDISTRIBUTIONCABLESOFRATEDVOLTAGE061KVXLPEINSULATPDF

链接地址:http://www.mydoc123.com/p-547111.html