BS 7870-3 22-2011 LV and MV polymeric insulated cables for use by distribution and generation utilities Specification for distribution cables of rated voltage 0 6 1 kV XLPE insulat.pdf
《BS 7870-3 22-2011 LV and MV polymeric insulated cables for use by distribution and generation utilities Specification for distribution cables of rated voltage 0 6 1 kV XLPE insulat.pdf》由会员分享,可在线阅读,更多相关《BS 7870-3 22-2011 LV and MV polymeric insulated cables for use by distribution and generation utilities Specification for distribution cables of rated voltage 0 6 1 kV XLPE insulat.pdf(24页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS 7870-3.22:2011Incorporating Corrigendum No. 1LV and MV polymericinsulated cables for use bydistribution and generationutilitiesPart 3: Specification for distributioncables of
2、rated voltage 0.6/1 kVSection 3.22: XLPE insulated splitconcentric cables with copper oraluminium conductors, having lowemission of smoke and corrosivegases when affected by fire(Implementation of HD 603)Publishing and copyright informationThe BSI copyright notice displayed in this document indicate
3、s when the documentwas last issued. The British Standards Institution 2012Published by BSI Standards Limited 2012ISBN 978 0 580 78837 6ICS 29.060.20The following BSI references relate to the work on this standard:Committee reference GEL/20/16Draft for comment 11/30214065 DCPublication historyFirst p
4、ublished December 2011Amendments issued since publicationDate Text affectedAugust 2012 See forewordBS 7870-3.22:2011 BRITISH STANDARDContentsForeword ii1 Scope 12 Normative references 13 Voltage designation 24 Phase conductors 25 Insulation 26 Assembly of cores 27 Bedding for 3-phase cables 28 Conce
5、ntric layer 29 Binder tapes 310 Oversheath 311 Marking 412 End sealing 513 Dimensions 514 Tests 815 Routine tests 916 Sample tests 917 Type tests 11AnnexesAnnex A (informative) Guide to selection and use of cables 13Annex B (normative) Test for shrinkage of oversheath on cable 14Bibliography 15List
6、of tablesTable 1 Cables with single phase copper conductor and split concentric copperneutral/earth conductors 6Table 2 Cables with single phase aluminium conductor and split concentriccopper neutral/earth conductors 6Table 3 Cables with 3-phase copper conductors and split concentric copperneutral/e
7、arth conductors 7Table 4 Cables with 3-phase aluminium conductors and split concentric copperneutral/earth conductors 7Table 5 Schedule of tests 8Table 6 Requirements for compatibility of insulation and oversheath 12Table A.1 Guide to use 13Summary of pagesThis document comprises a front cover, an i
8、nside front cover, pages i to iv,pages 1 to 16, an inside back cover and a back cover.BRITISH STANDARD BS 7870-3.22:2011 The British Standards Institution 2012 iForewordPublishing informationThis section of BS 7870 is published by BSI Standards Limited, under licence fromThe British Standards Instit
9、ution, and came into effect on 31 December 2011. Itwas prepared by Subcommittee GEL/20/16, Medium/High voltage cables, underthe authority of Technical Committee GEL/20, Electric cables. A list oforganizations represented on these committees can be obtained on request totheir secretary.Relationship w
10、ith other publicationsBS 7870 implements the nationally applicable parts of Harmonization DocumentsHD 603, 605, 620, 626 and 627 published by the European Committee forElectrotechnical Standardization (CENELEC) in accordance with the decision ofthe CENELEC Technical Board.BS 7870 applies to cables f
11、or fixed installations having a rated voltage U0/U upto and including 19/33 kV, and is published as a series of separate parts andsections, as listed in the table in the foreword of BS 7870-1.This new section of the standard, BS 7870-3.22, specifies a range of XLPEinsulated split concentric service
12、cables having low emission of smoke andcorrosive gases when affected by fire; it implements Part 5S of HD 603 S1 A2,and is to be read in conjunction with BS 7870-1 and BS 7870-2.Information about this documentThe start and finish of text introduced or altered by Corrigendum No. 1 isindicated in the
13、text by tagsand.A general guide to use for the types of cable specified in BS 7870 is given inBS 7870-1 and specific details for the types of cable specified in this section ofBS 7870 are given in Annex A.Hazard warningsWARNING. This British Standard calls for the use of substances and/orprocedures
14、that can be injurious to health if adequate precautions are nottaken. It refers only to technical suitability and does not absolve the userfrom legal obligations relating to health and safety at any stage.Use of this documentIt has been assumed in the preparation of this British Standard that theexe
15、cution of its provisions will be entrusted to appropriately qualified andexperienced people, for whose use it has been produced.Presentational conventionsThe provisions of this standard are presented in roman (i.e. upright) type. Itsrequirements are expressed in sentences in which the principal auxi
16、liary verb is“shall”.Commentary, explanation and general informative material is presented insmaller italic type, and does not constitute a normative element.BRITISH STANDARDBS 7870-3.22:2011ii The British Standards Institution 2012Contractual and legal considerationsThis publication does not purpor
17、t to include all the necessary provisions of acontract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legalobligations.BRITISH STANDARD BS 7870-3.22:2011 The British Standards Institution 2012 iiiBRITISH STANDARDBS 7870-3.22:2011This
18、 page deliberately left blankiv The British Standards Institution 20121 ScopeThis section of BS 7870 specifies requirements for the construction, dimensionsand mechanical and electrical properties of split concentric service cables havinga rated voltage of 0.6/1(1.2) kV. It is applicable to cables t
19、hat, when assessed bythe specified tests, produce lower levels of smoke and corrosive gases underexposure to fire than cables conforming to BS 7870-3.21.It specifies requirements for the following types of cable:a) single phase or 3-phase;b) stranded copper or solid aluminium conductors;c) XLPE insu
20、lation and PVC oversheath.This section of BS 7870 is applicable to cables that are designed for a maximumcontinuous conductor operating temperature of 90 C and for a maximum shortcircuit conductor temperature of 250 C.2 Normative referencesThe following referenced documents are indispensable for the
21、 application ofthis document. For dated references, only the edition cited applies. For undatedreferences, the latest edition of the referenced document (including anyamendments) applies.BS 3988:1970+A3:1989, Specification for wrought aluminium for electricalpurposes Solid conductors for insulated c
22、ablesBS 7870-1, LV and MV polymeric insulated cables for use by distribution andgeneration utilities Part 1: GeneralBS 7870-2, LV and MV polymeric insulated cables for use by distribution andgeneration utilities Part 2: Methods of testBS EN 50267-2-1, Common test methods for cables under fire condit
23、ions Testson gases evolved during combustion of materials from cables Part 2-1: Procedures Determination of the amount of halogen acid gasBS EN 60228, Specification for conductors in insulated cables and cordsBS EN 60332-1-2:2004, Tests on electric and optical fibre cables under fireconditions Part
24、1-2: Test for vertical flame propagation for a single insulatedwire or cable Procedure for 1 kW pre-mixed flameBS EN 60332-3-24:2009, Tests on electric and optical fibre cables under fireconditions Part 3-24: Test for vertical flame spread of vertically-mountedbunched wires or cables Category CBS EN
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS78703222011LVANDMVPOLYMERICINSULATEDCABLESFORUSEBYDISTRIBUTIONANDGENERATIONUTILITIESSPECIFICATIONFORDISTRIBUTIONCABLESOFRATEDVOLTAGE061KVXLPEINSULATPDF

链接地址:http://www.mydoc123.com/p-547110.html