BS 5803-5-1985 Thermal insulation for use in pitched roof spaces in dwellings - Specification for installation of man-made mineral fibre and cellulose fibre insulation《坡屋顶空间隔热 第5部分.pdf
《BS 5803-5-1985 Thermal insulation for use in pitched roof spaces in dwellings - Specification for installation of man-made mineral fibre and cellulose fibre insulation《坡屋顶空间隔热 第5部分.pdf》由会员分享,可在线阅读,更多相关《BS 5803-5-1985 Thermal insulation for use in pitched roof spaces in dwellings - Specification for installation of man-made mineral fibre and cellulose fibre insulation《坡屋顶空间隔热 第5部分.pdf(24页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS 5803-5: 1985 Incorporating Amendment No. 1 Thermal insulation for use in pitched roof spaces in dwellings Part 5: Specification for installation of man-made mineral fibre and cellulose fibre insulation UDC 699.86:692.42:677.46 + 677.52BS5803-5:1985 This British Standard, having b
2、een prepared under the directionof the Elements andComponents (of Diverse Materials) for Buildings Standards Committee, waspublished under the authorityofthe Board of BSIandcomes intoeffect on 28February 1985 BSI 07-1999 The following BSI references relate to the work on this standard: Committee ref
3、erence ECB/38 Draft for comment 83/10121 DC ISBN 0 580 14246 9 Committees responsible for this British Standard The preparation of this British Standard was entrusted by the Elements andComponents (of Diverse Materials) for Buildings Standards Committee (ECB/-) to Technical Committee ECB/38 upon whi
4、ch the following bodies were represented: Chartered Institution of Building Services Consumer Standards Advisory Committee of BSI Department of the Environment (Building Research Establishment, Fire Research Station) Department of the Environment (Housing and Construction Industries) Department of t
5、he Environment (Property Services Agency) Eurisol (UK) (Association of Manufacturers of Mineral Fibre Insulation) Greater London Council Independent Waste Paper Processors Association Institution of Building Control Officers National Association of Loft Insulation Contractors National Council of Bui
6、lding Materials Producers Royal Institute of British Architects Thermal Insulation Manufacturers Association Amendments issued since publication Amd. No. Date of issue Comments 8040 February1994 Indicated by a sideline in the marginBS5803-5:1985 BSI 07-1999 i Contents Page Committees responsible Ins
7、ide front cover Foreword ii 1 Scope 1 2 Definitions 1 3 Insulation materials 1 4 Condition of roof space 1 5 Assessment of work required in roof space 2 6 Application of insulation material 2 7 Application of additional insulation 7 8 Assessment of roof spaces after completion of work 10 9 Maintenan
8、ce 10 10 Certification 10 Appendix A Thermal insulation at rafter level 16 Appendix B Ventilation of roof space 16 Appendix C Avoidance of overheating of electric cables 18 Figure 1 Laying mat insulation with eaves ventilation baffle 3 Figure 2 Insulation with eaves ventilation 4 Figure 3 Soffit-les
9、s eaves: method of ventilating existing mat insulation 6 Figure 4 Insulation with eaves ventilation, cavity closure, insulation over joists 8 Figure 5 Blown fibre insulation with eaves ventilation and cavity closure 9 Figure 6 Insulation of elevated cold water tank 11 Figure 7 Insulation of cold wat
10、er tank on joists (mat material) 12 Figure 8 Insulation of cold water tank using sheet material 13 Figure 9 Insulation of loft hatch 14 Figure 10 Typical insulation of water pipes 15 Publications referred to Inside back coverBS5803-5:1985 ii BSI 07-1999 Foreword This Part of BS 5803 has been prepare
11、d under the direction of the Elements and Components (of Diverse Materials) for Building Standards Committee. The thermal transmittance of a ceiling to the roof space of a dwelling is reduced by the application of thermal insulation materials, either between or over the ceiling joists. This Part cov
12、ers the assessments of the roof and the methods of installing the insulation material. It covers the following situations: a) where the contract is for the insulation of a single dwelling; b) where the contract is for a number of dwellings. BS5803 comprises the following Parts: Part1: Specification
13、for man-made mineral fibre thermal insulation mats; Part2: Specification for man-made mineral fibre thermal insulation in pelleted or granular form for application by blowing; Part3: Specification for cellulose fibre thermal insulation for application by blowing; Part4: Methods for determining flamm
14、ability and resistance to smouldering; Part5: Specification for installation of man-made mineral fibre and cellulose fibre insulation. NOTEThis Part has been written in the form of a specification (see clause 6 of PD6501-1:1982). To comply with this specification, the user has to comply with all its
15、 requirements. He may depart from recommendations, but this would be on his own responsibility and he would be expected to have good reasons for doing so. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their c
16、orrect application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, pages1 to18, an inside back cover and a back cover. This standard has been updated (see cop
17、yright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover.BS5803-5:1985 BSI 07-1999 1 1 Scope This Part of BS5803 specifies requirements for the application of thermal insulation in pitched roof spaces in new and existing dwellings
18、. It covers both the insulation of an uninsulated roof and the application of additional insulation to increase the existing standard of insulation. Insulation at rafter level is not included but advice on this type of installation is given inAppendix A. The standard specifies essential procedures a
19、nd precautions to be undertaken, and makes recommendations to ensure an adequate installation. It covers fibrous materials that may be substantially inorganic or organic and may be in the form of mats or loose-fill suitable for application by blowing. It covers the following situations: a) an indivi
20、dual dwelling where the work is carried out by an insulation installer; b) a number of dwellings where the work is carried out by an insulation installer; c) an individual dwelling where the work is carried out without a contract. NOTEIn all cases the clauses covering workmanship apply. NOTEThe titl
21、es of the publications referred to in this standard are listed on the inside back cover. 2 Definitions For the purposes of this Part of BS5803 the definitions given in BS3533 and BS3589 apply together with the following. 2.1 mat a length of flexible man-made mineral fibre insulating material normall
22、y supplied as a roll or batt 2.2 batt mat in the form of rectangular pieces generally between1m and 2m in length, supplied packed flat or folded 2.3 loose-fill products in loose, granulated or pelleted form 2.4 blowing moving into position by a mechanically induced air current 2.5 cellulose fibre a
23、loose-fill insulation composed of cellulose (wood-based) fibre treated with fire retardant agents and biocidal additives 2.6 man-made mineral fibre a generic term for all man-made non-metallic inorganic fibres 2.7 insulation installer installer of thermal insulation material 2.8 R value thermal resi
24、stance (in m 2 K/W) assessed at the appropriate thickness NOTESee BS5803-1, BS5803-2 andBS5803-3. 3 Insulation materials The insulation material shall consist of one of the following: a) man-made mineral fibre mats complying with BS5803-1; b) man-made mineral fibre in pelleted or granular form compl
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS580351985THERMALINSULATIONFORUSEINPITCHEDROOFSPACESINDWELLINGSSPECIFICATIONFORINSTALLATIONOFMANMADEMINERALFIBREANDCELLULOSEFIBREINSULATION

链接地址:http://www.mydoc123.com/p-545404.html