BS 5467-2016 Electric cables Thermosetting insulated armoured cables of rated voltages of 600 1 000 V and 1 900 3 300 V for fixed installations Specification《电缆 用于固定装置的额定电压为600 100.pdf
《BS 5467-2016 Electric cables Thermosetting insulated armoured cables of rated voltages of 600 1 000 V and 1 900 3 300 V for fixed installations Specification《电缆 用于固定装置的额定电压为600 100.pdf》由会员分享,可在线阅读,更多相关《BS 5467-2016 Electric cables Thermosetting insulated armoured cables of rated voltages of 600 1 000 V and 1 900 3 300 V for fixed installations Specification《电缆 用于固定装置的额定电压为600 100.pdf(48页珍藏版)》请在麦多课文档分享上搜索。
1、BS 5467:2016Incorporating Corrigendum No. 1Electric cables Thermosetting insulated,armoured cables of ratedvoltages of 600/1 000 Vand 1 900/3 300 V for fixedinstallations SpecificationBSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06Publishing and copyright informatio
2、nThe BSI copyright notice displayed in this document indicates when the documentwas last issued. The British Standards Institution 2016Published by BSI Standards Limited 2016ISBN 978 0 580 95650 8ICS 29.060.20The following BSI references relate to the work on this document:Committee reference GEL/20
3、/17Draft for comment 15/30301501 DCPublication historyFirst published June 1977Second edition September 1989Third edition October 1997Fourth (present) edition April 2016Amendments issued since publicationDate Text affectedSeptember 2016 C1 See ForewordBS 5467:2016 BRITISH STANDARDContentsForeword ii
4、i1 Scope 12 Normative references 13 Terms and definitions 24 Rated voltage 35 Conductors 36 Insulation 47 Identification of cores 48 Laying-up 69 Bedding 610 Armour 711 Oversheath 812 Cable marking and additional information 913 End sealing 1114 Schedule of tests 1215 Test conditions 1316 Routine te
5、sts 1317 Sample tests 1418 Type tests 15AnnexesAnnex A (informative) Guide to use and installation of cables 22Annex B (normative) Armour wire tests 29Annex C (normative) Compatibility test 30Annex D (normative) Abrasion resistance test 31Annex E (normative) Insulation resistance constant test on ov
6、ersheath 31Annex F (normative) Resistance of conductor and armour 32Annex G (informative) Gross cross-sectional area of armour 34Annex H (normative) Test for shrinkage of oversheath on cable 35Annex I (informative) Guidance on type tests 36Annex J (informative) United Kingdom reference codes 38Bibli
7、ography 39List of figuresFigure1Anexample of the marking on the oversheath of the cable 10List of tablesTable 1 Maximum permitted voltages against rated voltage of cable 3Table 2 Diameter of steel armour wire and mass of zinc coating 7Table 3 Schedule of tests 12Table 4 Single-core 600/1 000 V cable
8、s with copper conductors 16Table5Two-core 600/1 000 V cables with copper conductors 17Table 6 Three-core 600/1 000 V cables with copper conductors 18Table 7 Four-core 600/1 000 V cables with copper conductors 19Table 8 Five-core 600/1 000 V cables with copper conductors 20Table 9 Multicore auxiliary
9、 600/1 000 V cables with copper conductors 20Table 10 Single-core 1 900/3 300 V cables with copper conductors 21Table 11 Three-core 1 900/3 300 V cables with copper conductors 21Table A.1 Selection of cables for a.c. systems 23Table A.2 Test voltages after installation 28Table B.1 Temperature correc
10、tion multiplication factors 30Table C.1 Compatibility requirements 31BRITISH STANDARD BS 5467:2016 The British Standards Institution 2016 iTable D.1 Vertical load requirements 31Table F.1 Maximum resistance of conductor and armour for single-corecable 32Table F.2 Maximum resistance of conductor and
11、armour for two-, three-,four- and five-core cable 33Table F.3 Maximum resistance of conductor and armour for 600/1 000 Vmulticore auxiliary cables 33Table G.1 Gross cross-sectional area of armour wires for thesingle-core 600/1 000 V cable 34Table G.2 Gross cross-sectional area of armour wires for tw
12、o-, three-, four- andfive-core 600/1 000 V cable 34Table G.3 Gross cross-sectional area of armour wires for 600/1 000 V auxiliarycable 35Table J.1 Historical cable codes included in BS 5467 38Summary of pagesThis document comprises a front cover, an inside front cover, pages i to iv,pages 1 to 40, a
13、n inside back cover and a back cover.BRITISH STANDARDBS 5467:2016ii The British Standards Institution 2016ForewordPublishing informationThis British Standard is published by BSI Standards Limited, under licence fromThe British Standards Institution, and came into effect on 30 April 2016. It wasprepa
14、red by Subcommittee GEL/20/17, Low voltage cables, under the authorityof Technical Committee GEL/20, Electric cables. A list of organizationsrepresented on these committees can be obtained on request to their secretary.SupersessionThis British Standard supersedes BS 5467:1997+A3:2008, which will be
15、withdrawnon 30 April 2017.Information about this documentThis is a full revision of the standard, and introduces the following principalchanges.a) The range of cables types is restricted to cables with copper conductors.b) The marking requirements have been updated and clarified.c) Test methods have
16、 been updated in accordance with the latestBS EN standards.d) 48-core auxiliary cables have been removed as they are no longer marketrelevant.The new edition takes account of: BS EN 50395 (replacing Annex K of BS 5467:1997) on electrical tests; BS EN 50396 (replacing Annex D of BS 5467:1997) on thic
17、knessmeasurement; BS EN 60332-1-2 (replacing BS EN 50265-2-1); and BS EN 62230 (replacing BS EN 50356 and BS 5099) on spark testing.Product certification/inspection/testingUsers of this British Standard are advised to consider the desirability ofthird-party certification/inspection/testing of produc
18、t conformity with this BritishStandard. Users seeking assistance in identifying appropriate conformityassessment bodies or schemes may ask BSI to forward their enquiries to therelevant association.Hazard warningsWARNING. This British Standard calls for the use of substances and/orprocedures that can
19、 be injurious to health if adequate precautions are nottaken. It refers only to technical suitability and does not absolve the userfrom legal obligations relating to health and safety at any stage.Use of this documentIt has been assumed in the preparation of this British Standard that theexecution o
20、f its provisions will be entrusted to appropriately qualified andexperienced people, for whose use it has been produced.Text introduced or altered by Corrigendum No. 1 is indicated in the text by tags. Minor editorial corrections are not tagged.BRITISH STANDARD BS 5467:2016 The British Standards Ins
21、titution 2016 iiiPresentational conventionsThe provisions of this standard are presented in roman (i.e. upright) type. Itsrequirements are expressed in sentences in which the principal auxiliary verb is“shall”.Commentary, explanation and general informative material is presented insmaller italic typ
22、e, and does not constitute a normative element.Contractual and legal considerationsThis publication does not purport to include all the necessary provisions of acontract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legalobligations
23、.BRITISH STANDARDBS 5467:2016iv The British Standards Institution 20161 ScopeThis British Standard specifies requirements for the construction andperformance of thermosetting insulated, armoured cables of rated voltagesof 600/1 000 V and 1 900/3 300 V.This British Standard is applicable to cables fo
24、r use in fixed installations inindustrial areas, buildings or similar applications.This British Standard specifies requirements for the following types of cables:a) 600/1 000 V cables, wire armoured and oversheathed, having single-core,two-, three-, four- and five-core stranded copper conductor;b) 6
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS54672016ELECTRICCABLESTHERMOSETTINGINSULATEDARMOUREDCABLESOFRATEDVOLTAGESOF6001000VAND19003300VFORFIXEDINSTALLATIONSSPECIFICATION

链接地址:http://www.mydoc123.com/p-545117.html