BS 4553-2-1998 Specification for 600 1000 V single-phase split concentric electric cables - Cables having thermosetting insulation《600 1000 V单相分芯同轴电缆规范 第2部分 带热固绝缘层的电缆》.pdf
《BS 4553-2-1998 Specification for 600 1000 V single-phase split concentric electric cables - Cables having thermosetting insulation《600 1000 V单相分芯同轴电缆规范 第2部分 带热固绝缘层的电缆》.pdf》由会员分享,可在线阅读,更多相关《BS 4553-2-1998 Specification for 600 1000 V single-phase split concentric electric cables - Cables having thermosetting insulation《600 1000 V单相分芯同轴电缆规范 第2部分 带热固绝缘层的电缆》.pdf(20页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS 4553-2:1998 Incorporating Amendments Nos. 1 and 2 Specification for 600/1 000 V single-phase split concentric electric cables Part 2: Cables having thermosetting insulation ICS 29.060.20 BS 4553-2:1998 This British Standard, having been prepared under the direction of the Electro
2、technical Sector Board, was published under the authority of the Standards Board and comes into effect on 15 August 1998 BSI 29 April 2005 First published, February 1970 Second edition, January 1988 Third edition, February 1992 The following BSI references relate to the work on this standard: Commit
3、tee reference GEL/20/2 Draft for comment 97/201035 DC ISBN 0 580 29575 3 Committees responsible for this British Standard The preparation of this British Standard was entrusted by Technical Committee GEL/20, Electric cables, to Subcommittee GEL/20/2, Mains cables, 1 kV and above, upon which the foll
4、owing bodies were represented: Association of Consulting Engineers British Approvals Service for Cables British Cables Association British Plastics Federation Electricity Association ERA Technology Ltd. London Underground Ltd. UK Steel Association Amendments issued since publication Amd. No. Date Co
5、mments 14193 5 February 2004 See foreword 15642 29 April 2005 Certification text in foreword changedBS 4553-2:1998 BSI 29 April 2005 i Contents Page Committees responsible Inside front cover Foreword ii 1S c o p e 1 2 Normative references 1 3 Definitions 1 4V o l t a g e d e s i g n a t i o n 2 5 Ph
6、ase conductor 2 6I n s u l a t i o n 3 7 Identification of phase core 3 8B e d d i n g 3 9 Concentric layer 3 10 Binders 4 11 Oversheath 4 12 Cable marking 4 13 End sealing 5 14 Schedule of tests 5 15 Test conditions 6 16 Routine tests 6 17 Sample tests 6 18 Type tests 6 Annex A (informative) Recomm
7、endations for the selection and operation of cables 9 Annex B (informative) Recommendations for installation of cables 9 Annex C (informative) Information to be provided with enquiry or order 10 Annex D (normative) Measurement of thickness 11 Annex E (normative) Voltage tests on completed cables 11
8、Annex F (Spare) 11 Annex G (normative) Compatibility test 11 Annex H (informative) Notes on type tests 11 Annex J (informative) Guide to use 12 Bibliography 15 Table 1 Schedule of tests 7 Table 2 Compatibility requirements 8 Table 3 600 / 1 000 V XLPE-insulated single-phase split concentric cables w
9、ith stranded copper phase conductors 8 Table 4 600 / 1 000 V XLPE-insulated single-phase split concentric cables with solid aluminium phase conductors 8BS 4553-2:1998 ii BSI 29 April 2005 Foreword This British Standard has been prepared by Subcommittee GEL/20/2. It is one of three parts of a full te
10、chnical revision of BS 4553:1992, which is withdrawn. The start and finish of text introduced or altered by amendment is indicated in the text by tags !“. Tags indicating changes to text carry the number of the amendment. For example, text altered by amendment No. 1 is indicated by !“. BS 4553-2 spe
11、cifies a range of thermosetting insulated split concentric cables. In addition, the standard contains the option of solid aluminium conductors or stranded copper conductors, as well as option of using a separate extruded bedding to build up the core to a diameter suitable for applying the split conc
12、entric layer. BS 4553-1 specifies a similar range of split concentric cables but which have PVC insulation. BS 4553-3 specifies a similar range of split concentric cables but which have thermosetting insulation and non-halogenated sheaths and a low emission of smoke and acid gas when affected by fir
13、e. Amendment No. 1:2004 implements the changes to the identification of cores by colours, in accordance with HD 308 S2. The principal identification colours are now: Single phase Green-and-yellow (Earth); blue (Neutral); brown (Live); Three phase Green-and-yellow (Earth); blue (Neutral); brown, blac
14、k, grey (Live). Users should ensure that any interconnection between cables with these new colours and those with the pre-existing ones is carried out safely. BS 7671, as amended in parallel with this standard, gives some guidance in this respect, but does not cover all installation conditions or ca
15、ble users. The provisions introduced by amendment No. 1:2004 are effective from 1 stApril 2004. The original version of this standard remains current until 31 stMarch 2006. Product certification/inspection/testing. Users of this British Standard are advised to consider the desirability of third-part
16、y certification/inspection/testing of product conformity with this British Standard. Users seeking assistance in identifying appropriate conformity assessment bodies or schemes may ask BSI to forward their enquiries to the relevant association. WARNING. This standard calls for the use of substances
17、and/or procedures that may be injurious to health if adequate precautions are not taken. It refers only to technical suitability and does not absolve the user from legal obligations relating to health and safety at any stage. Annex D, Annex E and Annex G are normative. Annex A, Annex B, Annex C, Ann
18、ex H and Annex J are informative. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document c
19、omprises a front cover, an inside front cover, pages i and ii, pages 1 to 15 and a back cover. BS 4553-2:1998 BSI 29 April 2005 1 1 Scope This British Standard specifies requirements for construction and gives methods of test for XLPE-insulated single-phase split concentric cables for operation on a
20、n earthed neutral system at nominal voltages up to and including 1 000 V between phases and 600 V to earth. The cables specified in this part of BS 4553 have a central phase conductor insulated with XLPE and a concentric layer comprising bare copper wires (earth continuity conductor) and copper wire
21、s covered with extruded polymer (neutral conductor). The cables are intended for use in fixed installations in industrial areas, buildings and similar applications. They are suitable for use in situations where the combination of ambient temperature and temperature rise due to loading current result
22、s in a conductor temperature not exceeding 90 C and for a maximum short-circuit conductor temperature of 250 C. NOTE 1 Limitation on the temperature of the cables may be imposed in situations where they may be touched. NOTE 2 Due to the relatively high conductor temperature, there is a risk of dryin
23、g out the surrounding soil causing an increase in thermal resistivity which in turn would lead to the cable temperature rising to a higher value than anticipated. For cable laid directly in the ground, a suitable de-rating factor should be applied or a lower maximum sustained conductor operating tem
24、perature should be assumed to take into account the possible effects of soil drying out. NOTE 3 In installations which include cable joints and terminations, the performance of these accessories should be taken into account in deciding the maximum operating temperature of the cable. Guidance concern
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS455321998SPECIFICATIONFOR6001000VSINGLEPHASESPLITCONCENTRICELECTRICCABLESCABLESHAVINGTHERMOSETTINGINSULATION6001000V

链接地址:http://www.mydoc123.com/p-544494.html