BS 4553-1-1998 Specification for 600 1000 V single-phase split concentric electric cables - Cables having PVC insulation《600 1000V单相分芯同轴电缆规范 第1部分 带聚氯乙烯绝缘层的电缆》.pdf
《BS 4553-1-1998 Specification for 600 1000 V single-phase split concentric electric cables - Cables having PVC insulation《600 1000V单相分芯同轴电缆规范 第1部分 带聚氯乙烯绝缘层的电缆》.pdf》由会员分享,可在线阅读,更多相关《BS 4553-1-1998 Specification for 600 1000 V single-phase split concentric electric cables - Cables having PVC insulation《600 1000V单相分芯同轴电缆规范 第1部分 带聚氯乙烯绝缘层的电缆》.pdf(20页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS 4553-1:1998 Incorporating Amendments Nos. 1 and 2 Specification for 600 /1 000 V single-phase split concentric electric cables Part 1: Cables having PVC insulation ICS 29.060.20 BS 4553-1:1998 This British Standard, having been prepared under the direction of the Electrotechnical
2、 Sector Board, was published under the authority of the Standards Board and comes into effect on 15 August 1998 BSI 29 April 2005 First published, February 1970 Second edition, January 1988 Third edition, February 1992 The following BSI references relate to the work on this standard: Committee refer
3、ence GEL/20/2 Draft for comment 97/201035 DC ISBN 0 580 29574 5 Committees responsible for this British Standard The preparation of this British Standard was entrusted by Technical Committee GEL/20, Electric cables, to Subcommittee GEL/20/2, Mains cables, 1 kV and above, upon which the following bod
4、ies were represented: Association of Consulting Engineers British Approvals Service for Cables British Cables Association British Plastics Federation Electricity Association ERA Technology Ltd. London Underground Ltd. UK Steel Association Amendments issued since publication Amd. No. Date Comments 14
5、194 4 February 2004 See foreword 15641 29 April 2005 Certification text in foreword changedBS 4553-1:1998 BSI 29 April 2005 i Contents Page Committees responsible Inside front cover Foreword ii 1S c o p e 1 2 Normative references 1 3 Definitions 1 4V o l t a g e d e s i g n a t i o n 2 5 Phase condu
6、ctor 2 6I n s u l a t i o n 3 7 Identification of phase core 3 8B e d d i n g 3 9 Concentric layer 3 10 Binders 4 11 Oversheath 4 12 Cable marking 4 13 End sealing 5 14 Schedule of tests 5 15 Test conditions 6 16 Routine tests 6 17 Sample tests 6 18 Type tests 6 Annex A (informative) Recommendations
7、 for the selection and operation of cables 9 Annex B (informative) Recommendations for installation of cables 9 Annex C (informative) Information to be provided with enquiry or order 10 Annex D (normative) Measurement of thickness 11 Annex E (normative) Voltage tests on completed cables 11 Annex F (
8、normative) Insulation resistance test 11 Annex G (normative) Compatibility test 11 Annex H (informative) Notes on type tests 12 Annex J (informative) Guide to use 12 Bibliography 15 Table 1 Schedule of tests 7 Table 2 Compatibility requirements 8 Table 3 600 / 1 000 V PVC-insulated single-phase spli
9、t concentric cables with stranded copper phase conductors 8 Table 4 600 / 1 000 V PVC-insulated single-phase split concentric cables with solid aluminium phase conductors 8BS 4553-1:1998 ii BSI 29 April 2005 Foreword This British Standard has been prepared by Subcommittee GEL/20/2. It is one of thre
10、e parts of a full technical revision of BS 4553:1992, which is withdrawn. The start and finish of text introduced or altered by amendment is indicated in the text by tags. Tags indicating changes to text carry the number of the amendment. For example, text altered by amendment No. 1 is indicated by
11、!“. BS 4553-1 specifies the range of PVC insulated split concentric cables originally incorporated in BS 4553:1992. In addition, the standard now contains the option of solid aluminium conductors or stranded copper conductors, as well as the option of using a separate extruded bedding to build up th
12、e core to a diameter suitable for applying the split concentric layer. BS 4553-2 specifies a similar range of split concentric cables but which have thermosetting insulation. BS 4553-3 specifies a similar range of split concentric cables, but which have thermosetting insulation and non-halogenated s
13、heaths and a low emission of smoke and acid gas when affected by fire. Amendment No. 1:2004 implements the changes to the identification of cores by colours, in accordance with HD 308 S2. The principal identification colours are now: Single phase Green-and-yellow (Earth); blue (Neutral); brown (Live
14、); Three phase Green-and-yellow (Earth); blue (Neutral); brown, black, grey (Live). Users should ensure that any interconnection between cables with these new colours and those with the pre-existing ones is carried out safely. BS 7671, as amended in parallel with this standard, gives some guidance i
15、n this respect, but does not cover all installation conditions or cable uses. The provisions introduced by amendment No. 1:2004 are effective from 1 stApril 2004. The original version of this standard remains current until 31 stMarch 2006. Product certification/inspection/testing. Users of this Brit
16、ish Standard are advised to consider the desirability of third-party certification/inspection/testing of product conformity with this British Standard. Users seeking assistance in identifying appropriate conformity assessment bodies or schemes may ask BSI to forward their enquiries to the relevant a
17、ssociation. WARNING. This standard calls for the use of substances and/or procedures that may be injurious to health if adequate precautions are not taken. It refers only to technical suitability and does not absolve the user from legal obligations relating to health and safety at any stage. Annex D
18、, Annex E, Annex F and Annex G are normative. Annex A, Annex B, Annex C, Annex H and Annex J are informative. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of its
19、elf confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, pages 1 to 15 and a back cover. The BSI copyright notice displayed in this document indicates when the document was last issued.BS 4553-1:1998 BSI 29 April 2005
20、1 1 Scope This British Standard specifies requirements for construction and gives methods of test for PVC-insulated single-phase split concentric cables for operation on an earthed neutral system at nominal voltages up to and including 1 000 V between phases and 600 V to earth. The cables specified
21、in this part of BS 4553 have a central phase conductor insulated with PVC and a concentric layer comprising bare copper wires (earth continuity conductor) and copper wires covered with extruded polymer (neutral conductor). The cables are intended for use in fixed installations in industrial areas, b
22、uildings and similar applications. They are suitable for use in situations where the combination of ambient temperature and temperature rise due to loading current results in a conductor temperature not exceeding 70 C, and for a maximum short-circuit conductor temperature of 160 C. Guidance concerni
23、ng selection, installation and usage is given in Annex A, Annex B, and Annex J respectively. 2 Normative references The following normative documents contain provisions which, through reference in this text, constitute provisions of this part of this British Standard. For dated references, subsequen
24、t amendments to, or revisions of, any of these publications do not apply. For undated references, the latest edition of the publication referred to applies. !Text deleted. “ BS 4727-2-08, Glossary of electrotechnical, power, telecommunication, electronics, lighting and colour terms Part 2: Terms par
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS455311998SPECIFICATIONFOR6001000VSINGLEPHASESPLITCONCENTRICELECTRICCABLESCABLESHAVINGPVCINSULATION6001000V

链接地址:http://www.mydoc123.com/p-544493.html