1、ANSI/BHMA A156.8-2015 Revision of ANSI/BHMA A156.8-2010 AMERICAN NATIONAL STANDARD FOR DOOR CONTROLS - OVERHEAD STOPS AND HOLDERS AMERICAN NATIONAL STANDARDS INSTITUTE Approved December 25, 2015 SPONSOR BUILDERS HARDWARE MANUFACTURERS ASSOCIATION, INC. 2 AMERICAN NATIONAL STANDARD An American Nation
2、al Standard implies a consensus of those substantially concerned with its scope and provisions. An American National Standard is intended as a guide to aid the manufacturer, the consumer, and the general public. The existence of American National Standard does not in any respect preclude anyone, whe
3、ther he has approved the standard or not, from manufacturing, marketing, purchasing, or using products, processes, or procedures not conforming to the standard. American National Standards are subject to periodic review and users are cautioned to obtain the latest editions. CAUTION NOTICE: This Amer
4、ican National Standard is permitted to be revised or withdrawn at any time. The procedures of the American National Standards Institute require that action be taken to reaffirm, revise, or withdraw this standard no later than five years from the date of publication. Purchasers of American National S
5、tandards receive current information on all Standards by calling or writing the American National Standards Institute. Published by BUILDERS HARDWARE MANUFACTURERS ASSOCIATION, INC. 355 Lexington Avenue, New York, NY 10017 Copyright 2015 by the Builders Hardware Manufacturers Association, Inc. Not
6、to be reproduced without specific authorization from B.H.M.A. Printed in the USA This standard was first published June 1970 by the Builders Hardware Manufacturers Association, Inc. It was entitled “Standard 311 BHMA Product Standards Section C, Door Controls - Overhead Holders.“ ANSI approval was s
7、ecured under the Canvass Method. BHMA was accredited on 21 March 1983 by ANSI as a sponsor using the Canvass Method. 3 FOREWORD (This foreword is not a part of ANSI A156.8). The general classification of builders hardware includes a wide variety of items which are divided into several categories. To
8、 recognize this diversity, a sectional classification system has been established. Overhead Holders is one such section and this Standard is the result of the collective efforts of members of the Builders Hardware Manufacturers Association who manufacture this product. The total Product Standards ef
9、fort is, therefore, a collection of sections, each covering a specific category of items. Performance tests have been established to insure safety, security and stability to which the public is entitled. There are no restrictions on design except as required to suit the type of product desired. The
10、BHMA recognizes that errors will be found, items will become obsolete, and new products, methods and material will be developed. With this in mind, the Association plans to update, correct and revise these Standards on a regular basis. In most cases products have been described in grade levels relat
11、ed to performance. Grade classifications indicate levels only within their own product category. Choice of grade and specific product should be made on the basis of utility, aesthetics, security objectives and end use desired. The BHMA numbers, which indicate types of hardware do not identify size o
12、r finish and are not intended to be used without necessary supplementary information. Individual manufacturers catalogs should be consulted. 4 TABLE OF CONTENTS 1. GENERAL 5 2. PERFORMANCE REQUIREMENTS . 5 3. FINISH TESTS . 7 4. TYPICAL FUNCTIONS AND IDENTIFYING NUMBERS . 8 5. EXPLANATION OF NUMBERI
13、NG SYSTEM . 10 APPENDIX A . 11 5 1. GENERAL 1.1 Scope 1.1.1 This Standard establishes requirements for overhead door stops and holders, and includes performance tests covering operational, cyclical, strength and finish criteria. 1.1.2 Tests described in this Standard are performed under laboratory c
14、onditions. In actual usage, results vary because of installation, maintenance and environmental conditions. 2 DEFINITIONS 2.1 Overhead Holder A device surface mounted or concealed at the top of a door with a connecting arm attached to the door frame. It holds a door in a predetermined open position
15、or positions and also limits the opening up to 110 degrees. 2.2 Overhead Stops A device surface mounted or concealed at the top of a door with a connecting arm attached to the door frame which only limits the opening travel of a door. 3 GENERAL REQUIREMENTS 3.1 SI Units All dimensions are expressed
16、first in US units with SI unit (metric) equivalents given in parentheses. SI units are approximate. 3.2 Tolerances All values which do not carry specific tolerances or are not marked maximum or minimum shall have the following tolerances: Number of cycles shall be minimum. Linear dimensions shall be
17、 + 1/16 in. (1.6 mm). Pounds or pound force shall be + 2%. A tolerance of + 2 degrees F shall be applied to temperature call outs. 3.3 Reference to ANSI Standards ANSI Standards are available from the American National Standards Institute, www.ansi.org, or the Builders Hardware Manufacturers Associa
18、tion . 3.4 Tests Required All Grades of stops and overhead holders are required to meet functional tests described in Section 4. All grades of overhead holders and stops are required to meet the applicable finish tests described in Section 5. 4. PERFORMANCE REQUIREMENTS 4.1 Test Procedures 4.1.1 All
19、 tests shall be performed on a door weighing 150-lbs (68-kg) with the center of gravity 18 in. from the hinge or pivot centerline of rotation. The door must accommodate a load application point 30 in. from the hinge or pivot centerline of rotation. 6 4.1.2 Means for mechanically opening the door to
20、the stop position and releasing and closing the door shall be provided for the tests. Opening speed shall be 0 to 90 degrees in 3 to 6 seconds. 4.1.3 Doors shall be hung on heavy weight ball bearing hinges or pivots Force required to overcome friction or out of balance condition shall be a .5 lbf (2
21、.2 N) or less, measured in accordance with paragraph 4.1.4. 4.1.4 All forces shall be applied to the door and readings shall be taken at a point 30 in (762 mm) from center line of hinge or pivot. 4.1.5 All tests shall be conducted using a single stop or holder. Failure of the stop or holder to compl
22、ete or meet the requirements of any part of the test shall constitute failure of test. 4.1.6 The Force Tests (4.3) shall be performed following completion of the Cycle Tests (4.2). 4.1.7 No lubrication shall be added to the stops or holders during these tests. 4.2. Cycle Test 4.2.1 Single Point Adju
23、stable Hold Open Types At the start of the test, with closer arm disconnected, door holders with a single point hold open function shall be adjusted to withstand a minimum of a 15 lbf (67 N) perpendicular to door in direction of closing without releasing. Doors shall be mechanically pushed or pulled
24、 into hold open, and pulled or pushed back to a closed position for the requirements specified in 4.2.6. Adjustment shall be checked at 1/2 the total cycles required and readjusted to the original holding force if necessary. At the conclusion of cycling, the force required to close the door shall be
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BHMAA15682015DOORCONTROLSOVERHEADSTOPSANDHOLDERS 门控 制器顶置门吸 固位 装置 PDF

链接地址:http://www.mydoc123.com/p-542515.html