ASTM G3-1989(2010) Standard Practice for Conventions Applicable to Electrochemical Measurements in Corrosion Testing《腐蚀检验中使用的电化测量的常规方法标准实施规程》.pdf
《ASTM G3-1989(2010) Standard Practice for Conventions Applicable to Electrochemical Measurements in Corrosion Testing《腐蚀检验中使用的电化测量的常规方法标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM G3-1989(2010) Standard Practice for Conventions Applicable to Electrochemical Measurements in Corrosion Testing《腐蚀检验中使用的电化测量的常规方法标准实施规程》.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: G3 89 (Reapproved 2010)Standard Practice forConventions Applicable to Electrochemical Measurementsin Corrosion Testing1This standard is issued under the fixed designation G3; the number immediately following the designation indicates the year of originaladoption or, in the case of revis
2、ion, the year of last revision.Anumber in parentheses indicates the year of last reapproval.Asuperscriptepsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers conventions for reporting anddisplaying electrochemical corrosion data. Conventions
3、forpotential, current density, electrochemical impedance and ad-mittance, as well as conventions for graphical presentation ofsuch data are included.1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard. See also 7.4.1.3 This stan
4、dard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 A
5、STM Standards:2IEEE/ASTM SI 10 Standard for Use of the InternationalSystem of Units (SI) (the Modern Metric System)3. Significance and Use3.1 This practice provides guidance for reporting, display-ing, and plotting electrochemical corrosion data and includesrecommendations on signs and conventions.
6、Use of this prac-tice will result in the reporting of electrochemical corrosiondata in a standard format, facilitating comparison between datadeveloped at different laboratories or at different times. Therecommendations outlined in this standard may be utilizedwhen recording and reporting corrosion
7、data obtained fromelectrochemical tests such as potentiostatic and potentiody-namic polarization, polarization resistance, electrochemicalimpedance and admittance measurements, galvanic corrosion,and open circuit potential measurements.4. Sign Convention for Electrode Potential4.1 The Stockholm sign
8、 invariant convention is recom-mended for use in reporting the results of specimen potentialmeasurements in corrosion testing. In this convention, thepositive direction of electrode potential implies an increasinglyoxidizing condition at the electrode in question. The positivedirection has also been
9、 denoted as the noble direction becausethe corrosion potentials of most noble metals, such as gold, aremore positive than the nonpassive base metals. On the otherhand, the negative direction, often called the active direction, isassociated with reduction and consequently the corrosionpotentials of a
10、ctive metals, such as magnesium. This conven-tion was adopted unanimously by the 1953 International Unionof Pure and Applied Chemistry as the standard for electrodepotential (1).34.2 In the context of a specimen electrode of unknownpotential in an aqueous electrolyte, consider the circuit shownin Fi
11、g. 1 with a reference electrode connected to the groundterminal of an electrometer. If the electrometer reads on scalewhen the polarity switch is negative, the specimen electrodepotential is negative (relative to the reference electrode).Conversely, if the electrometer reads on scale when polarity i
12、spositive, the specimen potential is positive. On the other hand,if the specimen electrode is connected to the ground terminal,the potential will be positive if the meter is on scale when thepolarity switch is negative, and vice versa.NOTE 1In cases where the polarity of a measuring instrument is in
13、doubt, a simple verification test can be performed as follows: connect themeasuring instrument to a dry cell with the lead previously on thereference electrode to the negative battery terminal and the lead previouslyon the specimen electrode to the positive battery terminal. Set the rangeswitch to a
14、ccommodate the dry cell voltage. The meter deflection will nowshow the direction of positive potential.Also, the corrosion potential of magnesium or zinc should be negativeina1N NaCl solution if measured against a saturated standard calomelelectrode (SCE).1This practice is under the jurisdiction of
15、ASTM Committee G01 on Corrosionof Metals and is the direct responsibility of Subcommittee G01.11 on Electrochemi-cal Measurements in Corrosion Testing.Current edition approved May 1, 2010. Published May 2010. Originallyapproved in 1968. Last previous edition approved in 2004 as G389(2004). DOI:10.15
16、20/G0003-89R10.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The boldface numbers in parentheses refer to
17、a list of references at the end ofthis standard.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5. Sign Convention for Electrode Potential TemperatureCoefficients5.1 There are two types of temperature coefficients ofelectrode potenti
18、al: isothermal temperature coefficients and thethermal coefficients. The sign convention recommended forboth types of temperature coefficients is that the temperaturecoefficient is positive when an increase in temperature pro-duces an increase (that is, it becomes more positive) in theelectrode pote
19、ntial. Likewise, the second temperature coeffi-cient is positive when an increase in temperature produces anincrease (that is, it becomes more positive) in the first tem-perature coefficient.6. Sign Convention for Current and Current Density6.1 The sign convention in which anodic currents andcurrent
20、 densities are considered positive and cathodic currentsand current densities are negative is recommended. When thepotential is plotted against the logarithm of the current density,only the absolute values of the current density can be plotted.In such plots, the values which are cathodic should be c
21、learlydifferentiated from the anodic values if both are present.7. Conventions for Displaying Polarization Data7.1 Sign ConventionsThe standard mathematical practicefor plotting graphs is recommended for displaying electro-chemical corrosion data. In this practice, positive values areplotted above t
22、he origin on the ordinate axis and to the right ofthe origin on the abscissa axis. In logarithmic plots, theabscissa value increases from left to right and the ordinatevalue increases from bottom to top.7.2 Current Density-Potential PlotsAuniform conventionis recommended for plotting current density
23、-potential data,namely, plot current density along the abscissa and potentialalong the ordinate. In current density potential plots, thecurrent density may be plotted on linear or logarithmic axes. Ingeneral, logarithmic plots are better suited to incorporation ofwide ranges of current density data
24、and for demonstrating Tafelrelationships. Linear plots are recommended for studies inwhich the current density or potential range is small, or in caseswhere the region in which the current density changes fromanodic to cathodic is important. Linear plots are also used forthe determination of the pol
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMG319892010STANDARDPRACTICEFORCONVENTIONSAPPLICABLETOELECTROCHEMICALMEASUREMENTSINCORROSIONTESTING

链接地址:http://www.mydoc123.com/p-540580.html