DLA SMD-5962-87620 REV E-2009 MICROCIRCUIT HYBRID LINEAR HIGH POWER OPERATIONAL AMPLIFIER.pdf
《DLA SMD-5962-87620 REV E-2009 MICROCIRCUIT HYBRID LINEAR HIGH POWER OPERATIONAL AMPLIFIER.pdf》由会员分享,可在线阅读,更多相关《DLA SMD-5962-87620 REV E-2009 MICROCIRCUIT HYBRID LINEAR HIGH POWER OPERATIONAL AMPLIFIER.pdf(13页珍藏版)》请在麦多课文档分享上搜索。
1、 REVISIONS LTR DESCRIPTION DATE (YR-MO-DA) APPROVED A Remove vendor CAGE 13919. Add device type 02. Add vendors CAGE 31757 and 60024. Change to reflect MIL-H-38534 processing. Editorial changes throughout. 91-09-13 Tim H. Noh B Table I, device type 01, correct output voltage peak and output current
2、peak tests. 00-01-11 Raymond Monnin C Drawing updated to reflect current requirements. -sld 02-12-16 Raymond Monnin D Figure 1, case outline X, dimension C, delete 0.260“ minimum and change 0.300“ maximum to 0.340“ maximum. 03-09-25 Raymond Monnin E Table I, input offset current, device type 01, sub
3、group 2, change min/max limits from 7 nA to 15 nA. Table I, current limits, device type 02, change test conditions to VCC= 14 V dc, RCL= 1 , RL= 6 and change min/max limits to 0.6 A / 0.89 A. Table II, add note to Group C end-point test parameters. -gz 09-07-27 Charles F. Saffle THE ORIGINAL FIRST S
4、HEET OF THIS DRAWING HAS BEEN REPLACED. REV SHEET REV SHEET REV STATUS REV E E E E E E E E E E E E OF SHEETS SHEET 1 2 3 4 5 6 7 8 9 10 11 12 PMIC N/A PREPARED BY Donald R. Osborne DEFENSE SUPPLY CENTER COLUMBUS STANDARD MICROCIRCUIT DRAWING CHECKED BY D. A. Di Cenzo COLUMBUS, OHIO 43218-3990http:/w
5、ww.dscc.dla.mil THIS DRAWING IS AVAILABLE FOR USE BY ALL DEPARTMENTS APPROVED BY N. A. Hauck MICROCIRCUIT, HYBRID, LINEAR, HIGH POWER OPERATIONAL AMPLIFIER AND AGENCIES OF THE DEPARTMENT OF DEFENSE DRAWING APPROVAL DATE 87-09-16 AMSC N/A REVISION LEVEL E SIZE A CAGE CODE 67268 5962-87620 SHEET 1 OF
6、12 DSCC FORM 2233 APR 97 5962-E397-09Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-87620 DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 REVISION LEVEL E SHEET 2 DSCC FORM 2234 APR 97 1. SCOPE 1.1
7、Scope. This drawing documents one product assurance class, class H (high reliability) and a choice of case outlines and lead finishes are available and are reflected in the Part or Identifying Number (PIN). 1.2 PIN. The PIN shall be as shown in the following example: 5962-87620 01 X X Drawing number
8、 Device type Case outline Lead finish (see 1.2.1) (see 1.2.2) (see 1.2.3) 1.2.1 Device type(s). The device type(s) identify the circuit function as follows: Device type Generic number Circuit function 01 42106, PA51M-1/883 High power operational amplifier 02 42106-1, PA51M/883 High power operational
9、 amplifier 1.2.2 Case outlines. The case outlines are as designated in MIL-STD-1835 and as follows: Outline letter Descriptive designator Terminals Package style X See figure 1 8 Flange mount Y See figure 1 8 Flange mount 1.2.3 Lead finish. The lead finish shall be as specified in MIL-PRF-38534. 1.3
10、 Absolute maximum ratings. Supply voltage range 40 V dc maximum Differential input voltage . VCC- 3 V Common mode input VCCMaximum power dissipation (PD): Device type 01 80 W 1/ Device type 02 97 W 2/ Thermal resistance, junction-to-case (JC): Device type 01 2.2C/W Device type 02 1.8C/W Junction tem
11、perature (TJ) . +200C Lead temperature (soldering, 10 seconds) . +300C Storage temperature range . -65C to +150C 1.4 Recommended operating conditions. Supply voltage (VCC) 34 V dc Operating temperature range: Device type 01 (TA) . -55C to +125C Device type 02 (TC) . -55C to +125C 1/ At ambient tempe
12、rature of +25C, derate at 2.2C/W above ambient temperature of +25C. 2/ At case temperature of +25C, derate at 1.8C/W above case temperature of +25C. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-87620 DEFEN
13、SE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 REVISION LEVEL E SHEET 3 DSCC FORM 2234 APR 97 2. APPLICABLE DOCUMENTS 2.1 Government specification, standards, and handbooks. The following specification, standards, and handbooks form a part of this drawing to the extent specified herein. Unless
14、otherwise specified, the issues of these documents are those cited in the solicitation or contract. DEPARTMENT OF DEFENSE SPECIFICATION MIL-PRF-38534 - Hybrid Microcircuits, General Specification for. DEPARTMENT OF DEFENSE STANDARDS MIL-STD-883 - Test Method Standard Microcircuits. MIL-STD-1835 - In
15、terface Standard for Electronic Component Case Outlines. DEPARTMENT OF DEFENSE HANDBOOKS MIL-HDBK-103 - List of Standard Microcircuit Drawings. MIL-HDBK-780 - Standard Microcircuit Drawings. (Copies of these documents are available online at http:/assist.daps.dla.mil/quicksearch/ or from the Standar
16、dization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.2 Order of precedence. In the event of a conflict between the text of this drawing and the references cited herein, the text of this drawing takes precedence. Nothing in this document, however, supersedes
17、applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 Item requirements. The individual item performance requirements for device class H shall be in accordance with MIL-PRF-38534. Compliance with MIL-PRF-38534 may include the performance of all tests here
18、in or as designated in the device manufacturers Quality Management (QM) plan or as designated for applicable device class. The manufacturer may eliminate, modify or optimize the tests and inspections herein, however the performance requirements as defined in MIL-PRF-38534 shall be met for the applic
19、able device class. In addition, the modification in the QM plan shall not affect the form, fit, or function of the device for the applicable device class. 3.2 Design, construction, and physical dimensions. The design, construction, and physical dimensions shall be as specified in MIL-PRF-38534 and h
20、erein. 3.2.1 Case outlines. The case outlines shall be in accordance with 1.2.2 herein and on figure 1. 3.2.2 Terminal connections. The terminal connections shall be as specified on figure 2. 3.3 Electrical performance characteristics. Unless otherwise specified herein, the electrical performance ch
21、aracteristics are as specified in table I and shall apply over the full specified operating temperature range. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-87620 DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OH
22、IO 43218-3990 REVISION LEVEL E SHEET 4 DSCC FORM 2234 APR 97 3.4 Electrical test requirements. The electrical test requirements shall be the subgroups specified in table II. The electrical tests for each subgroup are defined in table I. 3.5 Marking of devices. Marking of devices shall be in accordan
23、ce with MIL-PRF-38534. The device shall be marked with the PIN listed in 1.2 herein. In addition, the manufacturers vendor similar PIN may also be marked. 3.6 Data. In addition to the general performance requirements of MIL-PRF-38534, the manufacturer of the device described herein shall maintain th
24、e electrical test data (variables format) from the initial quality conformance inspection group A lot sample, for each device type listed herein. Also, the data should include a summary of all parameters manually tested, and for those which, if any, are guaranteed. This data shall be maintained unde
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLASMD596287620REVE2009MICROCIRCUITHYBRIDLINEARHIGHPOWEROPERATIONALAMPLIFIERPDF

链接地址:http://www.mydoc123.com/p-699046.html