《ASTM F2608-2007 Standard Test Method for Determining the Change in Room Air Particulate Counts as a Result of the Vacuum Cleaning Process《测定作为真空清洁处理结果的室内空气颗粒计数变化用标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM F2608-2007 Standard Test Method for Determining the Change in Room Air Particulate Counts as a Result of the Vacuum Cleaning Process《测定作为真空清洁处理结果的室内空气颗粒计数变化用标准试验方法》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 2608 07An American National StandardStandard Test Method forDetermining the Change in Room Air Particulate Counts asa Result of the Vacuum Cleaning Process1This standard is issued under the fixed designation F 2608; the number immediately following the designation indicates the year o
2、foriginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method provides a laboratory test for themeasur
3、ement of particulate generated as a direct result of thevacuuming process.1.2 This test method is applicable to all residential/commercial uprights, canisters, stickvacs, central vacuum sys-tems, and combination cleaners.1.3 This test method applies to test dust removal from floorcoverings not the r
4、emoval of surface litter and debris.1.4 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.5 This test method may involve hazardous materials,operations, and equipment. This standard does not purport toaddress all of the safety
5、concerns, if any, associated with itsuse. It is the responsibility of the user of this standard toestablish appropriate safety and health practices and deter-mine the applicability of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2F 555 Test Method for Motor Life Eval
6、uation of an UprightVacuum CleanerF 608 Test Method for Evaluation of Carpet Embedded DirtRemoval Effectiveness of Household/Commercial VacuumCleanersF 655 Specification for Test Carpets and Pads for VacuumCleaner TestingF 884 Test Method for Motor Life Evaluation of a Built-In(Central Vacuum) Vacuu
7、m CleanerF 922 Test Method for Motor Life Evaluation of an ElectricMotorized NozzleF 1038 Test Method for Motor Life Evaluation of a Canis-ter, Hand-held, Stick, and Utility Type Vacuum CleanerWithout a Driven AgitatorF 1334 Test Method for Determining A-Weighted SoundPower Level of Vacuum CleanersF
8、 1409 Test Method for Straight Line Movement of VacuumCleaners While Cleaning Carpets2.2 AHAM Standard:ANSI/AHAM AC-1-2006 Test Method for Performance ofPortable Household Electric Room Air Cleaners32.3 Other References:IEC 60312 Vacuum Cleaners for Household UseMethodsfor Measuring the PerformanceS
9、tandard Laboratory Practice for Quantifying RespirableParticulate Emissions Generated by Residential/Commercial Vacuums and Central Vacuum Systems, Car-pet and Rug Institute, 12/4/023. Terminology3.1 Definitions:3.1.1 model, ndesignation of a group of vacuum cleanershaving identical mechanical and e
10、lectrical construction withonly cosmetic or nonfunctional differences.3.1.2 population, ntotal of all units of a particular modelvacuum cleaner being tested.3.1.3 repeatability limit, nvalue below which the absolutedifference between two individual test results obtained underthe repeatability condit
11、ion may be expected to occur with aprobability of approximately 0.95 (95 %).3.1.4 test run, ndefinitive procedure that produces asingular measured result.3.1.5 unit, nsingle vacuum cleaner of the model beingtested.4. Significance and Use4.1 In this test method, the amount of particulate generatedint
12、o the air by operating a vacuum cleaner over a specific floorcovering that is contaminated with dust will be determined.Particles from the motor, floor covering, and the test dust willall be measured. The amount of dust generated in the labora-tory practice will differ from that in residential/comme
13、rcialinstallations because of variations in floor coverings, soil andother solid particulate compositions, the vacuuming process1This test method is under the jurisdiction of ASTM Committee F11 on VacuumCleaners and is the direct responsibility of Subcommittee F11.23 on Filtration.Current edition ap
14、proved April 1, 2007. Published May 2007.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from the
15、Association of Home Appliance Manufacturers, 19th St.NW, Suite 402, Washington, DC 20036.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.used by individual operators, the air exchange rate of heating,ventilation, and air conditioning
16、 (HVAC) systems, and otherfactors.4.2 To provide a uniform basis for measuring the perfor-mance in 4.1, a standardized test chamber, equipment, floorcovering material, and dust particulate are used in this testmethod.5. Apparatus5.1 An air-conditioned laboratory at 21 6 1.5C(70 6 5F) and 50 % relati
17、ve humidity 65 % is to be used forsample preparation.5.2 Environmentally Controlled Test Chamber (per ANSI/AHAM AC-1-2006):5.2.1 Chamber SizeNominal dimensions of 3.2 by 3.7 by2.4 m (10.5 by 12 by 8 ft) up to a 20 % difference in volumeis permitted.5.2.2 FrameworkStandard 5.1 by 10.2 cm (2 by 4 in.)
18、 orequivalent construction sealed to the floor line with caulkingcompound.5.2.3 WallsAny hard, cleanable surface, such as wall-board (sealed with a washable latex semi-gloss paint) orstainless steel. Seal with caulking compound.5.2.4 FlooringAny hard, seamless cleanable surface suchas seamless full-
19、width vinyl, stainless steel, or sealed concrete.5.2.5 FiltrationHEPA filtration (99.97 % at 0.3 m, 0.5m3/s (1000 ft3/min) minimum).5.2.6 Motor and Blower for Conditioning Loop0.35-m3/s(750-ft3/min) fan.5.2.7 Relative Humidity50 6 5%.5.2.8 Temperature21 6 1.5C (70 6 5F).5.2.9 Chamber SealingChamber
20、sealing shall be verifiedas follows: Particulate level in the sealed room shall not riseabove 1000 particles/ft3at $0.3 m after 20 min of HEPA off,with the room static.5.3 Real-time aerosol particle counter in the range of 0.3 to5 m. A laser photometer may be used, in addition to theparticle counter
21、, with a range of 0.1 to 1000 g/m3.5.4 Particulate sampling pickoff probe shall be 152.4 6 12.7cm (60 6 5 in.) above the test carpet, facing up, on centerlineof carpet.5.5 Weighing Scale (for Weighing Test Dirt), accurate to0.01 g (0.000353 oz) and having a weighing capacity of at least100 g (3.53 o
22、z) for weighing the dust for embedding.5.6 Dirt Embedment ToolRoller may be locked or un-locked (see Fig. 1).5.7 Dirt DispenserDispensing system that provides theoperator with a method to distribute the test dirt uniformly onthe carpet test area.5.8 Voltmeter, to measure input volts to the vacuum cl
23、eaner,to provide measurements accurate within 61%.5.9 Voltage-Regulator System, to control the input voltageto the vacuum cleaner. The regulator shall be capable ofmaintaining the vacuum cleaners rated voltage 61 % andrated frequency having a wave form that is essentially sinusoi-dal with 3 % maximu
24、m harmonic distortion for the duration ofthe test.5.10 Carpet bed length of 182.9 cm (72 in.) and minimumwidth of 68.6 cm (27 in.). See an example of a suitablecleaning bed apparatus in Fig. 2.5.11 Drive for carpet or vacuum cleaner capable of main-taining specified test speed of 55 cm/s (1.8 ft/s)
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF26082007STANDARDTESTMETHODFORDETERMININGTHECHANGEINROOMAIRPARTICULATECOUNTSASARESULTOFTHEVACUUMCLEANINGPROCESS

链接地址:http://www.mydoc123.com/p-539080.html