ASTM F2561-2017 Standard Practice for Rehabilitation of a Sewer Service Lateral and Its Connection to the Main Using a One Piece Main and Lateral Cured-in-Place Liner《使用整体式主衬里和侧向就地.pdf
《ASTM F2561-2017 Standard Practice for Rehabilitation of a Sewer Service Lateral and Its Connection to the Main Using a One Piece Main and Lateral Cured-in-Place Liner《使用整体式主衬里和侧向就地.pdf》由会员分享,可在线阅读,更多相关《ASTM F2561-2017 Standard Practice for Rehabilitation of a Sewer Service Lateral and Its Connection to the Main Using a One Piece Main and Lateral Cured-in-Place Liner《使用整体式主衬里和侧向就地.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F2561 16F2561 17Standard Practice forRehabilitation of a Sewer Service Lateral and Its Connectionto the Main Using a One Piece Main and Lateral Cured-in-Place Liner1,2This standard is issued under the fixed designation F2561; the number immediately following the designation indicates th
2、e year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This practice covers requirements and test method
3、s for the reconstruction of a sewer service lateral pipe having an innerdiameter of 3 to 12 in. (7.6 to 30.5 cm) and its connection to the main pipe having an inner diameter of 6 to 24 in. (15.2 to 61.0cm) and up the lateral a maximum of 150 ft without excavation. The lateral pipe is accessed remote
4、ly from the main pipe and froma lateral cleanout. access point. This will be accomplished by the installation of a resin impregnated one-piece main and lateralcured-in-place lining (MLCIPL) by means of air or water inflation and inversion. The MLCIPL is pressed against the host pipeby pressurizing a
5、 bladder and is held in place until the thermoset resins have cured.When cured, the MLCIPLshall be a continuous,one piece, tight fitting, corrosion resistant lining extending over a predetermined length of the lateral pipe and the adjacent sectionof the main pipe, providing a verifiable non-leaking
6、structural connection and seal.1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information only and are not considered standard.1.3 There is no similar or equivalent ISO Standard.1
7、.4 WarningMercury has been designated by many regulatory agencies as a hazardous substance that can cause seriousmedical issues. Mercury, or its vapor, has been demonstrated to be hazardous to health and corrosive to materials. Caution shouldbe taken when handling mercury and mercury-containing prod
8、ucts. See the applicable product Safety Data Sheet (SDS) foradditional information. Users should be aware that selling mercury or mercury-containing products, or both, may be prohibited bylocal or national law.1.5 This standard does not purport to address all of the safety concerns, if any, associat
9、ed with its use. It is the responsibilityof the user of this standard to establish appropriate safety safety, health, and healthenvironmental practices and determine theapplicability of regulatory limitations prior to use. Particular attention is drawn to those safety regulations and requirementsinv
10、olving entering into and working in confined spaces.1.6 This international standard was developed in accordance with internationally recognized principles on standardizationestablished in the Decision on Principles for the Development of International Standards, Guides and Recommendations issuedby t
11、he World Trade Organization Technical Barriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:3D618 Practice for Conditioning Plastics for TestingD790 Test Methods for Flexural Properties of Unreinforced and Reinforced Plastics and Electrical Insulating MaterialsD1600 Terminology
12、 for Abbreviated Terms Relating to Plastics1 This practice is under the jurisdiction of ASTM Committee F17 on Plastic Piping Systems and is the direct responsibility of Subcommittee F17.67 on Trenchless PlasticPipeline Technology.Current edition approved April 1, 2016Dec. 1, 2017. Published May 2016
13、January 2018. Originally approved in 2006. Last previous edition approved in 20112016 asF2561.16. DOI: 10.1520/F2561-16.10.1520/F2561-17.2 The rehabilitation of a sewer service lateral and its connection to the main using a one-piece main and lateral cured-in-place liner is covered by patents (LMK E
14、nterprises,Inc. 1779 Chessie Lane, Ottawa, IL 61350). Interested parties are invited to submit information regarding the identification of acceptable alternatives to this patented itemto the Committee on Standards, ASTM Headquarters, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959. Your comm
15、ents will receive careful consideration at ameeting of the responsible technical committee which may attend.3 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the stand
16、ards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accuratel
17、y, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Driv
18、e, PO Box C700, West Conshohocken, PA 19428-2959. United States1D3681 Test Method for Chemical Resistance of “Fiberglass” (GlassFiberReinforcedThermosetting-Resin) Pipe in a DeflectedConditionD5813 Specification for Cured-In-Place Thermosetting Resin Sewer Piping SystemsF412 Terminology Relating to
19、Plastic Piping SystemsF1216 Practice for Rehabilitation of Existing Pipelines and Conduits by the Inversion and Curing of a Resin-Impregnated TubeF3097 Practice for Installation of an Outside Sewer Service Cleanout through a Minimally Invasive Small Bore VacuumExcavation2.2 NASSCO Guidelines:4Recomm
20、ended Specifications for Sewer Collection System Rehabilitation3. Terminology3.1 DefinitionsUnless otherwise indicated, definitions are in accordance with Terminology F412, and abbreviations are inaccordance with Terminology D1600.3.2 Definitions of Terms Specific to This Standard:3.2.1 access point
21、an existing manhole at either the upstream or downstream end of a sewer main or a cleanout or a pipeopening located on the lateral pipe.3.2.2 bladdera transparenttranslucent flexible plastic hose that when pressurized, causes the main sheet to be pressed againstthe main pipe walls and the lateral tu
22、be to invert up into the sewer service lateral. The bladder joined with the textile lining createsa liner/bladder assembly.3.2.3 inversionthe process of turning a resin-impregnated tube inside out by the use of air or water pressure.3.2.4 launchercombination of a rigid elongated tube and lay-flat ho
23、se apparatus where the main bladder is attached and themain sheet is wrapped around the exterior of the rigid portion. The lateral bladder and lateral tube are drawn inside the hose. Thelauncher is positioned within the main pipe; air pressure is introduced into the hose causing inflation of the mai
24、n bladder/sheet andinversion of the lateral bladder tube.3.2.5 lifta portion of the MLCIPL that has cured in a position such that it has pulled away from the host pipe wall.3.2.6 main and lateral cured-in-place lining (MLCIPL)a textile including plastic coating impregnated by a thermosettingresin. T
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF25612017STANDARDPRACTICEFORREHABILITATIONOFASEWERSERVICELATERALANDITSCONNECTIONTOTHEMAINUSINGAONEPIECEMAINANDLATERALCUREDINPLACELINER

链接地址:http://www.mydoc123.com/p-538983.html