ASTM F2414-2004(2016) Standard Practice for Sealing Sewer Manholes Using Chemical Grouting《采用化学灌浆密封下水道人孔的标准实施规程》.pdf
《ASTM F2414-2004(2016) Standard Practice for Sealing Sewer Manholes Using Chemical Grouting《采用化学灌浆密封下水道人孔的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM F2414-2004(2016) Standard Practice for Sealing Sewer Manholes Using Chemical Grouting《采用化学灌浆密封下水道人孔的标准实施规程》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F2414 04 (Reapproved 2016)Standard Practice forSealing Sewer Manholes Using Chemical Grouting1This standard is issued under the fixed designation F2414; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last
2、revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers proposed selection of materials,installation techniques, and inspection required for sealingmanholes u
3、sing chemical grout. Manholes or sections ofmanholes with active leaks shall be repaired. Manholes to begrouted are of brick, block, cast-in-place concrete, precastconcrete, or fiberglass construction. Manholes or sections ofmanholes with active leaks will be designated by the engineer,owners repres
4、entative, or authorized inspector, for manholegrouting.1.2 The contractor shall be responsible for furnishing alllabor, supervision, materials, equipment, and inspectionfollow-up required for the completion of chemical grouting ofmanhole defects in accordance with the contract documents.1.3 Material
5、s, additives, mixture ratios, and proceduresutilized for the grouting process shall be in accordance withmanufacturers recommendations and shall be appropriate forthe application.1.4 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematical
6、conversions to SI units that are provided for information onlyand are not considered standard.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health pra
7、ctices and determine the applica-bility of regulatory limitations prior to use.2. Terminology2.1 Definitions of Terms Specific to This Standard:2.1.1 acrylamideorganic solid of white, odorless, acrylicresinous material available in flake-like crystals and in liquidform. The greatest use of acrylamid
8、e is as a coagulant aid indrinking water treatment. Other major uses of acrylamide arein soil stabilization, in grout for repairing sewers and inacrylamide gels used in biotechnology laboratories.2.1.2 acrylatea general term applied to various water-soluble acrylic resinous materials.2.1.3 authorize
9、d inspectorthe person(s) contracted or ap-proved by the owner or owners representative to do inspec-tions.2.1.4 catalystsubstance which markedly speeds up thecure of an adhesive when added in small quantities ascompared to the amounts of primary reactants.2.1.5 chemical groutinjection repair media o
10、ther thancementitious grout that may be multi-component, with orwithout additives, and based on either polyurethane resin oracrylic resin.2.1.6 control agentsubstance added which controls theviscosity or flow properties of the material it is added to.2.1.7 engineeran engineer registered in the state
11、 wherethe work is to be done who has been contracted by or is actingon behalf of the owner or the owners representative.2.1.8 exfiltrationleaking or weeping to the external areasoutside the barrier from a source inside the barrier.2.1.9 expanded gasket procedure (EGP)the sealing ofjoints, cracks, or
12、 holes by soaking dry, oil-free oakum withchemical grout and forcing the oakum/resin plug into theopening until it sets.2.1.10 hydrophilic grouthydrophilic grout will absorb andreact with the water it comes into contact with.2.1.11 hydrophobic grouthydrophobic grout will repelwater and push it away.
13、2.1.12 manholevertical shafts that intersect with sewers toallow transitions in alignment and grade and to allow entry forcleaning, inspection, and maintenance.2.1.13 oakumloose hemp or jute fiber, sometimes treatedwith resin or grout, used chiefly for caulking seams instructures and boats as well a
14、s packing pipe joints.2.1.14 owners representativethe individual who has beencontracted to act on behalf of the owner for project planningand supervision.2.1.15 polyurethane resinany of various polymer resinscontaining the urethane radical; a wide variety of syntheticforms are made and used as adhes
15、ives, plastics, foams, paints,or rubber-like materials.1This practice is under the jurisdiction of ASTM Committee F36 on Technologyand Underground Utilitiesand is the direct responsibility of Subcommittee F36.20on Inspection and Renewal of Water and Wastewater Infrastructure.Current edition approved
16、 April 1, 2016. Published May 2016. Originallyapproved in 2004. Last previous edition approved in 2009 as F2414 04(2009).DOI: 10.1520/F2414-04R16.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States12.1.16 RCPreinforced concrete pipe.2.1.1
17、7 rehabilitated manholea manhole restored to itsintended capacity or use per the specifications.2.1.18 repaired or sealed manholea manhole that hasbeen sealed from detected infiltration or exfiltrations, but notnecessarily restored to its original designed capacity.2.1.19 sewerwaste water sewer or s
18、torm drain sewer.3. Significance and Use3.1 This practice is used as a guide for the installation ofchemical grout in the practice of sealing sewer manholes fromleaks, cracks, and around penetrations. It is attended to assistsewer owners and engineer, owners representative, or autho-rized inspectors
19、 for installation method specification and forcontractors to refer to during installations of chemical grout formanhole sealing.4. Materials4.1 Grouting MaterialsChemical grout sealing material:4.1.1 Acrylamide base gel,4.1.2 Acrylic base gel,4.1.3 Hydrophilic polyurethane foam or gel,4.1.4 Hydropho
20、bic polyurethane foam or gel, and4.1.5 Oil-free, oakum-soaked polyurethane resin.4.2 Grouting Materials CharacteristicsSpecific character-istics that pertain to the application requirements are to bedefined and approved by the owners representative or projectengineer of record. The following general
21、 characteristics orproperties shall be exhibited by the chemical grout:4.2.1 The chemical grout shall have documented service ofsatisfactory performance in similar usage and should have amanufacturers written guarantee of performance for the appli-cation of sewer manhole sealing under intended condi
22、tions andwhen installed per the manufacturers instructions.4.2.2 The chemical grout shall have controllable reactiontimes and minimal shrinkage, as specified by the owner,owners representative, or engineer, through the use of chemi-cals supplied by the same manufacturer. The minimum set timeshall be
23、 established so that adequate grout travel is achieved.4.2.3 The chemical grout shall have resistance to chemicals,most organic solvents, mild acids, and alkali. The manufacturerof the chemical grout shall be able to certify that the curedchemical grout is resistant to chemicals, most organic solven
24、ts,mild acids, and alkali and provide such certification to thecontractor when requested.4.2.4 The chemical grout shall be essentially non-toxic in acured form. The manufacturer of the chemical grout shall beable to certify that the cured chemical grout is non-toxic andprovide such certification to
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF241420042016STANDARDPRACTICEFORSEALINGSEWERMANHOLESUSINGCHEMICALGROUTING 采用 化学 灌浆 密封 下水 道人 标准 实施

链接地址:http://www.mydoc123.com/p-538640.html