《ASTM F1596-2000(2005) Standard Practice for Exposure of Membrane Switches to Temperature and Relative Humidity《温度和相对湿度对薄膜开关影响的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM F1596-2000(2005) Standard Practice for Exposure of Membrane Switches to Temperature and Relative Humidity《温度和相对湿度对薄膜开关影响的标准实施规程》.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 1596 00 (Reapproved 2005)Standard Practice forExposure of Membrane Switches to Temperature andRelative Humidity1This standard is issued under the fixed designation F 1596; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revisi
2、on, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers a procedure for temperature andhumidity cycling of membrane switches.1.2 This pr
3、actice is designed to determine changes inducedby temperature and humidity.1.3 This practice is not intended to be a thermal shockprocedure; a gradual ramp rate between conditions is required.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It
4、 is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Terminology2.1 Definition:2.1.1 membrane switcha momentary switching device inwhich at least one contact is on, or made
5、of, a flexiblesubstrate.3. Significance and Use3.1 Changes in temperature and humidity during shipping,storage or use can affect the visual appearance, mechanicalintegrity, or electrical functionality of switches. This practicesimulates three different environments to which membraneswitches may be e
6、xposed.3.2 The three industry-recognized switch categories basedon performance levels are Level 1, Level 2, and Level 3 (seesection 7.1).3.3 Additionally, there may be custom requirements thatvary by application, therefore, these requirements can bedetermined by customer and vendor agreement and be
7、estab-lished as a Level 4.3.4 This practice defines the duration of a single cycle.Multiple cycles may be appropriate depending on the require-ments of the application.4. Apparatus4.1 Closed system, with temperature and humidity control.24.2 The formation of condensation during rising tempera-ture c
8、ycles is acceptable; the formation of ice during lowtemperature cycling is not acceptable.5. Test Specimens5.1 The specimens shall be finished switches as deliveredand mounted to an actual or agreed upon substrate.6. Conditioning6.1 Condition all specimens for 72 h at 20 to 25C (68 to77F) and 20 to
9、80 % relative humidity (RH) immediately priorto exposure, or prior to temperature and humidity cycling. Thisis to enable the specimens to stabilize.7. Procedure7.1 Subject the preconditioned specimens to the exposuretest cycle as illustrated in Table 1.7.2 Return to room temperature and prepare for
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF159620002005STANDARDPRACTICEFOREXPOSUREOFMEMBRANESWITCHESTOTEMPERATUREANDRELATIVEHUMIDITY 温度 相对湿度

链接地址:http://www.mydoc123.com/p-535226.html