ASTM D8141-2017 0625 Standard Guide for Selecting Volatile Organic Compounds (VOCs) and Semi-Volatile Organic Compounds (SVOCs) Emission Testing Methods to Determine Emission Param.pdf
《ASTM D8141-2017 0625 Standard Guide for Selecting Volatile Organic Compounds (VOCs) and Semi-Volatile Organic Compounds (SVOCs) Emission Testing Methods to Determine Emission Param.pdf》由会员分享,可在线阅读,更多相关《ASTM D8141-2017 0625 Standard Guide for Selecting Volatile Organic Compounds (VOCs) and Semi-Volatile Organic Compounds (SVOCs) Emission Testing Methods to Determine Emission Param.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D8141 17Standard Guide forSelecting Volatile Organic Compounds (VOCs) and Semi-Volatile Organic Compounds (SVOCs) Emission TestingMethods to Determine Emission Parameters for Modeling ofIndoor Environments1This standard is issued under the fixed designation D8141; the number immediately
2、 following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide
3、is intended to serve as a foundation forunderstanding when to use emission testing methods designedfor volatile organic compounds (VOCs) to determine area-specific emission rates that are typically used in modelingindoor VOC concentrations and when to use emission testingmethods designed for semi-vo
4、latile organic compounds(SVOCs) to determine mass transfer emission parameters thatare typically used to model indoor SVOC concentrations.1.2 This guide discusses how organic chemicals are conven-tionally categorized with respect to volatility.1.3 This guide presents a simplified mass transfer model
5、describing organic chemical emissions from a material to bulkair. The values of the model parameters are shown to bespecific to material/chemical/chamber combinations.1.4 This guide shows how to use a mass transfer model toestimate whether diffusion of the chemical within the materialor convective m
6、ass transfer of the chemical from the surface ofthe material to the overlying air limits chemical emissions fromthe material surface.1.5 This guide describes the range of different chambers thatare available for emission testing. The chambers are classifiedas either dynamic or static and either conv
7、entional or sand-wich. The chambers are categorized as being optimal todetermine either the area-specific emission rate or mass trans-fer emission parameters.1.6 This guide discusses the roles sorption and convectivemass transfer coefficients play in selecting the proper emissionchamber and analysis
8、 method to accurately and efficientlycharacterize emissions from indoor materials for use in mod-eling indoor chemical concentrations.1.7 This guide gives recommendations on when to choosean emission test method that is optimized to determine eitherthe area-specific emission rate or mass transfer em
9、issionparameters. For chemicals where the controlling mass transferprocess is unknown, the guide outlines a procedure to deter-mine if the chemical emission is controlled by convective masstransfer of the chemical from the material.1.8 This guide does not provide specific guidance formeasuring emiss
10、ion parameters.1.9 Mechanisms controlling emissions from wet and drymaterials and products are different. This guide considers theemission of chemicals from dry materials and products. Ex-amples of SVOCs that this guide applies to include flameretardants, plasticizers, antioxidants, preservatives, a
11、nd co-alescing agents (1).2Emission estimations for other SVOCclasses including those generated by incomplete combustion,sprayed, or applied as a powder (pesticides, termiticides,herbicides, stain repellents, sealants, water repellants) (1) mayrequire different approaches than outlined in this guide
12、.1.10 The effects of the emissions (for example, exposure,and health effects on occupants) are not addressed and arebeyond the scope of this guide.1.11 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.12 This standard does not
13、purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety, health, and environmental practices and deter-mine the applicability of regulatory limitations prior to use.1.13 This international st
14、andard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.1T
15、his guide is under the jurisdiction of ASTM Committee D22 on Air Qualityand is the direct responsibility of Subcommittee D22.05 on Indoor Air.Current edition approved Oct. 1, 2017. Published October 2017. DOI: 10.1520/D8141-17.2The boldface numbers in parentheses refer to the list of references at t
16、he end ofthis standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for
17、theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.12. Referenced Documents2.1 ASTM Standards:3D1356 Terminology Relating to Sampling and Analysis ofAtmospheresD5116 Guide for Small-Scale Environmen
18、tal Chamber De-terminations of Organic Emissions from Indoor Materials/ProductsD6007 Test Method for Determining Formaldehyde Concen-trations in Air from Wood Products Using a Small-ScaleChamberD6177 Practice for Determining Emission Profiles of Vola-tile Organic Chemicals Emitted from Bedding SetsD
19、6330 Practice for Determination of Volatile Organic Com-pounds (Excluding Formaldehyde) Emissions from Wood-Based Panels Using Small Environmental Chambers Un-der Defined Test ConditionsD6345 Guide for Selection of Methods for Active, Integra-tive Sampling of Volatile Organic Compounds in AirD6670 P
20、ractice for Full-Scale Chamber Determination ofVolatile Organic Emissions from Indoor Materials/ProductsD7706 Practice for Rapid Screening of VOC Emissionsfrom Products Using Micro-Scale ChambersE1333 Test Method for Determining Formaldehyde Concen-trations in Air and Emission Rates from Wood Produc
21、tsUsing a Large Chamber2.2 Other Documents:Directive 2004/42/CE of the European Parliament and of theCouncil on the limitation of emissions of volatile organiccompounds due to the use of organic solvents in certainpaints and varnishes and vehicle refinishing products andamending Directive 1999/13/EC
22、Emission Testing Method for CDPH Standard Method V1.2.,2017 Standard Method for the Testing and Evaluation ofVolatile Organic Chemical Emissions from IndoorSources using Environmental Chambers, Indoor Air Qual-ity Section, Environmental Health Laboratory Branch,Division of Environmental and Occupati
23、onal DiseaseControl, California Department of Public HealthI.S. EN 16402:2013 Paints and VarnishesAssessment ofEmissions of Substances from Coatings into Indoor AirSampling, Conditioning, and TestingISO 16000-6:2011 Indoor AirPart 6: Determination ofVolatile Organic Compounds in Indoor and Test Cham
24、berAir by Active Sampling on Tenax TA Sorbent, ThermalDesorption and Gas Chromatography using MS or MS-FIDISO 12219-1 Interior Air of Road VehiclesPart 1: WholeVehicle Test ChamberSpecification and Method for theDetermination of volatile Organic Compounds in CabinInteriors3. Terminology3.1 Definitio
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD814120170625STANDARDGUIDEFORSELECTINGVOLATILEORGANICCOMPOUNDSVOCSANDSEMIVOLATILEORGANICCOMPOUNDSSVOCSEMISSIONTESTINGMETHODSTODETERMINEEMISSIONPARAMPDF

链接地址:http://www.mydoc123.com/p-526772.html