ASTM D3916-2008 Standard Test Method for Tensile Properties of Pultruded Glass-Fiber-Reinforced Plastic Rod《挤拔玻璃纤维增强塑料棒张力特性的试验方法》.pdf
《ASTM D3916-2008 Standard Test Method for Tensile Properties of Pultruded Glass-Fiber-Reinforced Plastic Rod《挤拔玻璃纤维增强塑料棒张力特性的试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3916-2008 Standard Test Method for Tensile Properties of Pultruded Glass-Fiber-Reinforced Plastic Rod《挤拔玻璃纤维增强塑料棒张力特性的试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 3916 08Standard Test Method forTensile Properties of Pultruded Glass-Fiber-ReinforcedPlastic Rod1This standard is issued under the fixed designation D 3916; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of
2、 last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope*1.1 This test method describes a proce
3、dure for determiningthe tensile properties of pultruded, glass-fiber-reinforced ther-mosetting plastic rod of diameters ranging from 3.2 mm (18 in.)to 25.4 mm (1 in.). Little test specimen preparation is required;however, reusable aluminum tab grip adapters (Fig. 1)ofappropriate size are required to
4、 prevent premature failure of thespecimens at the grips.1.2 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresp
5、onsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. Specific hazardsstatements are given in Note 3 and Note 4.NOTE 1There is no known ISO equivalent to this test method.2. Referenced Do
6、cuments2.1 ASTM Standards:2D 618 Practice for Conditioning Plastics for TestingD 638 Test Method for Tensile Properties of PlasticsE4 Practices for Force Verification of Testing MachinesE83 Practice for Verification and Classification of Exten-someter Systems3. Significance and Use3.1 The high axial
7、-tensile strength and the low transverse-compressive strength of pultruded rod combine to present someunique problems in determining the tensile strength of thismaterial with conventional test grips. The high transverse-compressive forces generated in the conventional method ofgripping tend to crush
8、 the rod, thereby causing prematurefailure. In this test method, aluminum-alloy tabs contoured tothe shape of the rod reduce the compressive forces imparted tothe rod, thus overcoming the deleterious influence of conven-tional test grips.3.2 Tensile properties are influenced by specimen prepara-tion
9、, strain rate, thermal history, and the environmental condi-tions at the time of testing. Consequently, where precisecomparative results are desired, these factors must be carefullycontrolled.3.3 Tensile properties provide useful data for many engi-neering design purposes. However, due to the high s
10、ensitivityof these properties to strain rate, temperature, and otherenvironmental conditions, data obtained by this test methodshould not, by themselves, be considered for applicationsinvolving load-time scales or environmental conditions thatdiffer widely from the test conditions. In cases where su
11、chdissimilarities are apparent, the sensitivities to strain rate,including impact and creep, as well as to environment, shouldbe determined over a wide range of conditions as dictated bythe anticipated service requirements.4. Apparatus4.1 Water-Cooled Diamond or Tungsten-Carbide Saw, forcutting rod
12、to size.4.2 Micrometer, reading to at least 0.025 6 0.000 mm(0.001 6 0.000 in.), for measuring the width and thickness ofthe test specimens. The thickness of nonrigid plastics (rein-forced pultruded products are rigid) should be measured with adial micrometer that exerts a pressure of 25 6 kPa (3.6
13、6 0.7psi) on the specimen and measures the thickness to within0.025 mm (0.001 in.). The anvil of the micrometer shall be atleast 30 mm (1.4 in.) in diameter and parallel to the face of thecontact foot.4.3 Universal Testing Machine, verified in accordance withPractices E4, having a capacity of at lea
14、st 530 kN (120 000lbf) to permit the testing of 25.4 mm (1 in.) diameter rod.1This test method is under the jurisdiction of ASTM Committee D20 on Plasticsand is the direct responsibility of Subcommittee D20.18 on Reinforced Thermoset-ting Plastics.Current edition approved March 1, 2008. Published Ma
15、rch 2008. Originallyapproved in 1980. Last previous edition approved in 2002 as D3916 - 02.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Su
16、mmary page onthe ASTM website.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.Smaller-diameter rod may be tested on lower-capacity equip-ment, commensurate with the an
17、ticipated tensile strength ofsuch rod.4.4 ExtensometerA suitable instrument for determiningthe distance between two designated points located within thegage length of the test specimen as the specimen is stretched.It is desirable, but not essential, that this instrument automati-cally record this di
18、stance (or any change in it) as a function ofthe load on the test specimen or of the elapsed time from thestart of the test, or both. If only the latter is obtained, load-timedata must also be taken. This instrument shall be essentiallyfree of inertia lag at the specified speed of testing and shall
19、beaccurate to 61 % of strain or better.NOTE 2Reference is made to Practice E83.4.5 One Pair of 6061 T6 Aluminum-Alloy Tab Grip Adapt-ers, as described in Fig. 1 and Table 1, to fit in split wedge-typeaction jaws of the testing machine.4.6 Solvent, such as methylene chloride, for cleaning thegripping
20、 surfaces of the aluminum-alloy tab grip adapters toremove any mold release, oil, or other foreign material thatmight act as a lubricant. The improper use of solvents canpresent hazardous conditions. Use of proper equipment, ven-tilation, and training of personnel in proper techniques shouldbe pract
21、iced to minimize hazards associated with the use of anyvolatile solvent.5. Test Specimens5.1 At least five specimens shall be cut from the rod sampleof interest. Specimen length shall be as great as possible,commensurate with the physical limitations of the testingmachine.NOTE 3Caution: When fabrica
22、ting composite specimens by machin-ing operations, a fine dust consisting of particles of fibers or the matrixmaterial, or both, may be formed. These fine dusts can be a health or safetyhazard, or both. Adequate protection should be afforded operating person-nel and equipment. This may require adequ
23、ate ventilation or dustcollecting facilities, or both, at a minimum.6. Conditioning6.1 Standard conditioning shall be in accordance with Pro-cedure A of Practice D 618.6.2 Tests at other than standard laboratory atmosphericconditions should be described, including time (hours), tem-perature, and tes
24、t environment, such as watersoak, and so forth.Tests should be made as near to these conditions as possible.7. Number of Test Specimens7.1 At least five specimens shall be tested for each sample.When specimens are preconditioned (for example, water-boiled or oven-aged) prior to test, five specimens
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD39162008STANDARDTESTMETHODFORTENSILEPROPERTIESOFPULTRUDEDGLASSFIBERREINFORCEDPLASTICROD 玻璃纤维 增强塑料

链接地址:http://www.mydoc123.com/p-515795.html