ASTM D3237-2006e1 Standard Test Method for Lead in Gasoline by Atomic Absorption Spectroscopy《原子吸收光谱法测定汽油中铅含量的标准试验方法》.pdf
《ASTM D3237-2006e1 Standard Test Method for Lead in Gasoline by Atomic Absorption Spectroscopy《原子吸收光谱法测定汽油中铅含量的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3237-2006e1 Standard Test Method for Lead in Gasoline by Atomic Absorption Spectroscopy《原子吸收光谱法测定汽油中铅含量的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 3237 06e1An American National StandardStandard Test Method forLead in Gasoline by Atomic Absorption Spectroscopy1This standard is issued under the fixed designation D 3237; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revis
2、ion, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.e1NOTECorrected footnote refere
3、nces in Paragraph X1.6 editorially in April 2007.1. Scope*1.1 This test method covers the determination of the totallead content of gasoline within the concentration range of0.010 to 0.10 g of lead/U.S. gal (2.5 to 25 mg/L). This testmethod compensates for variations in gasoline compositionand is in
4、dependent of lead alkyl type.1.2 The values given in grams per U.S. gallon are to beregarded as the standard in the United States. Note that in othercountries, other units can be preferred.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is
5、 theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specific hazardstatements, see 6.6 and 6.8.2. Referenced Documents2.1 ASTM Standards:2D 1193 Specification for Reagent Wa
6、terD 1368 Test Method for Trace Concentrations of Lead inPrimary Reference FuelsD 2550 Test Method for Water Separation Characteristics ofAviation Turbine Fuels3D3116 Test Method for Trace Amounts of Lead in Gaso-line3D 4057 Practice for Manual Sampling of Petroleum andPetroleum ProductsD 6299 Pract
7、ice for Applying Statistical Quality AssuranceTechniques to Evaluate Analytical Measurement SystemPerformance3. Summary of Test Method3.1 The gasoline sample is diluted with methyl isobutylketone and the alkyl lead components are stabilized by reactionwith iodine and a quaternary ammonium salt. The
8、lead contentof the sample is determined by atomic absorption flamespectrometry at 283.3 nm, using standards prepared fromreagent grade lead chloride. By the use of this treatment, allalkyl lead compounds give identical response.4. Significance and Use4.1 This test method is used to ensure compliance
9、 of tracelead as required by federal regulation for lead-free gasoline (40CFR part 80).5. Apparatus5.1 Atomic Absorption Spectrometer, capable of scale ex-pansion and nebulizer adjustment, and equipped with a slotburner and premix chamber for use with an air-acetylene flame.5.2 Volumetric Flasks, 50
10、-mL, 100-mL, 250-mL, and 1-Lsizes.5.3 Pipets, 2-mL, 5-mL, 10-mL, 20-mL, and 50-mL sizes.5.4 Micropipet, 100-L, Eppendorf type or equivalent.6. Reagents6.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents shall conform to
11、 the specifications of the Commit-tee on Analytical Reagents of the American Chemical Society,where such specifications are available.46.2 Purity of WaterUnless otherwise indicated, referencesto water shall be understood to mean reagent water as definedby Types II or III of Specification D 1193.6.3
12、Aliquat 336 (tricapryl methyl ammonium chloride).1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products and Lubricants and is the direct responsibility of SubcommitteeD02.03 on Elemental Analysis.Current edition approved Dec. 1, 2006. Published January 2007. Originall
13、yapproved in 1973. Last previous edition approved in 2002 as D 323702.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM
14、 website.3Withdrawn.4Reagent Chemicals, American Chemical Society Specifications, AmericanChemical Society, Washington, DC. For suggestions on the testing of reagents notlisted by the American Chemical Society, see Analar Standards for LaboratoryChemicals, BDH Ltd., Poole, Dorset, U.K., and the Unit
15、ed States Pharmacopeiaand National Formulary, U.S. Pharmacopeial Convention, Inc. (USPC), Rockville,MD.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.6.4 Aliquat 336/
16、MIBK Solution (10 % volume pervolume)Dissolve and dilute 100 mL (88.0 g) of Aliquat 336with MIBK to 1 L.6.5 Aliquat 336/MIBK Solution (1 % volume per volume)Dissolve and dilute 10 mL (8.8 g) of Aliquat 336 with MIBKto1L.6.6 Iodine SolutionDissolve and dilute 3.0 g of iodinecrystals with toluene to 1
17、00 mL. (WarningFlammable.Vapor harmful.)6.7 Lead Chloride (PbCl2).6.8 Lead-Sterile GasolineGasoline containing less than0.005 g Pb/gal (1.32 mg Pb/L). (WarningExtremely flam-mable. Harmful if inhaled. Vapors may cause flash fire.)NOTE 1One way to confirm lead concentrations of less than 0.005 gPb/ga
18、l (1.32 mg Pb/L) is to refer to Test Methods D 1368 and D3116.Aprocedure for the purification of gas turbine fuel appears in Appendix X4of Test Method D 2550 and can be used to decrease the lead concentrationof low lead gasoline in lead-sterile gasoline.6.9 Lead, Standard Solution (5.0 g Pb/gal (1.3
19、2 g Pb/L)Dissolve 0.4433 g of lead chloride (PbCl2) previously dried at105C for 3 h in about 200 mL of 10 % Aliquat 336/MIBKsolution in a 250-mL volumetric flask. Dilute to the mark withthe 10 % Aliquat solution, mix, and store in a brown bottlehaving a polyethylene-lined cap. This solution contains
20、 1321g Pb/mL, which is equivalent to 5.0 g Pb/gal.6.10 Lead, Standard Solution (1.0 g Pb/gal (264 mg Pb/L)By means of a pipet, accurately transfer 50.0 mL of the5.0 g Pb/gal (1.32 g Pb/L) solution to a 250-mL volumetricflask, dilute to volume with 1 % Aliquat/MIBK solution. Storein a brown bottle ha
21、ving a polyethylene-lined cap.6.11 Lead, Standard Solutions (0.02, 0.05, and 0.10 gPb/gal (5.3, 13.2, and 26.4 mg Pb/L)Transfer accurately bymeans of pipets 2.0, 5.0, and 10.0 mL of the 1.0-g Pb/gal (264mg Pb/L) solution to 100-mL volumetric flasks; add 5.0 mL of1 % Aliquat 336 solution to each flas
22、k; dilute to the mark withMIBK. Mix well and store in bottles having polyethylene-linedcaps.6.12 Methyl Isobutyl Ketone (MIBK), (4-methyl-2-pentanone).6.13 Quality Control (QC) Samples, preferably are portionsof one or more liquid petroleum materials that are stable andrepresentative of the samples
23、of interest. These QC samplescan be used to check the validity of the testing process asdescribed in Section 11.7. Sampling7.1 Take samples of gasoline in compliance with the in-structions in Practice D 4057.7.2 Collect sample in a metal container that can be sealedagainst leakage and store under te
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD32372006E1STANDARDTESTMETHODFORLEADINGASOLINEBYATOMICABSORPTIONSPECTROSCOPY 原子 吸收光谱 测定 汽油 含量 标准

链接地址:http://www.mydoc123.com/p-514366.html