ASTM D984-1997(2002) Standard Test Methods for Reducible Sulfur in Paper《测定纸中可还原硫的标准试验方法》.pdf
《ASTM D984-1997(2002) Standard Test Methods for Reducible Sulfur in Paper《测定纸中可还原硫的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D984-1997(2002) Standard Test Methods for Reducible Sulfur in Paper《测定纸中可还原硫的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 984 97 (Reapproved 2002)Technical Association of Pulp and Paper IndustryStandard Method T 406 Su-72An American National StandardStandard Test Methods forReducible Sulfur in Paper1This standard is issued under the fixed designation D 984; the number immediately following the designatio
2、n indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 These test methods cover the determ
3、ination of reduciblesulfur in paper and paperboard within the context of the givendefinitions.1.1.1 Method BThe semiquantitative method indicates thegeneral level of reducible sulfur with limited accuracy.1.1.2 Method AThe quantitative method gives a measureof the reducible sulfur with much greater
4、accuracy.2,31.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2.
5、Referenced Documents2.1 ASTM Standards:D 585 Practice for Sampling and Accepting a Single Lot ofPaper, Paperboard, Fiberboard, and Related Product4D 644 Test Method for Moisture Content of Paper andPaperboard by Oven Drying4D 1968 Terminology Relating to Paper and Paper Products4D 2043 Test Method f
6、or Silver Tarnishing by Paper43. Terminology3.1 DefinitionsDefinitions shall be in accordance withTerminology D 1968 and the Dictionary of Paper.54. Summary of Test Methods4.1 Method B, semiquantitative method, involves the reduc-tion of various forms of sulfur to hydrogen sulfide and thedevelopment
7、 of a dark spot of lead sulfide on the filter paperimpregnated with lead acetate. The intensity of the spot iscompared with spots developed from standards and is propor-tional to the concentration. No colorimeter or spectrophotom-eter is needed for this method.4.2 Method A, the quantitative method,
8、uses the identicalreduction system to generate hydrogen sulfide, but the sulfideis precipitated by alkaline cadmium sulfate and then convertedto methylene blue by reaction with acidicp-aminodimethylaniline in the presence of ferric chloride. Themethylene blue is measured spectrophotometrically and t
9、heintensity is compared with standards prepared in similarmanner.5. Significance and Use5.1 The test methods outlined are not necessarily a measureof how much a given test material will tarnish polished metals.When tested by these methods, paper that has less than0.0008 % reducible sulfur, may be as
10、sumed to be nontarnishingas far as sulfur is concerned, but if more than 0.0008 %, thisdoes not necessarily mean that tarnishing will occur, becausesulfur compounds which may not cause staining are reduced bythe treatment with the subsequent evolution of hydrogensulfide. If more than 0.0008 % reduci
11、ble sulfur is found, or ifthe effect of that or other materials causing stains on silver isdesired, the paper should be subjected to an acceleratedtarnishing test (see Test Method D 2043).NOTE 1If the pH of the paper is low (for example, 4.0 to 4.5 (coldextraction) as little as 0.0002 % of reducible
12、 sulfur may cause tarnishingof imitation gold bronze prints; whereas, if the pH were higher, (forexample, on brush-coated art paper) a much higher quantity of sulfurmight be tolerated.5.2 The test methods described do not give the total sulfurcontent, nor the total reducible sulfur content, nor are
13、theyintended to. They are limited to the reducible sulfur contentdetermined under the conditions of the test (that is, a fairlymild reduction system).35.2.1 Those forms of sulfur believed to be “reducible” underthe test conditions are (1) sulfide (released by the acid, notactually reduced), (2) elem
14、ental sulfur, (3) thiosulfate, (4) otherpolythionates or polysulfides, and (5) perhaps sulfite. Sulfate isexcluded.1These test methods are under the jurisdiction of ASTM Committee D06 onPaper and Paper Products and are the direct responsibility of Subcommittee D06.92on Test Methods.Current edition a
15、pproved Dec. 10, 1997. Published November 1998. Originallypublished as D 984 48 T. Last previous edition D 984 92 (1996).2Sobolev, I., Bhargava, R., Gosuntov, N., and Russell, R., Tappi 39(9):628(1956).3Chazin, J. D., “Colorimetric Determination of Reducible Sulfur in Paper andPaperboard,” Tappi, Jo
16、urnal of the Technical Association of the Pulp and PaperIndustry, TAPPI, Vol 53, No. 8, 1970, p. 1514.4Annual Book of ASTM Standards, Vol 15.09.5Available from the Technical Association of the Pulp and Paper Industry, P.O.Box 105113, Atlanta, GA 30348.1Copyright ASTM International, 100 Barr Harbor D
17、rive, PO Box C700, West Conshohocken, PA 19428-2959, United States.6. Sampling6.1 Obtain the sample in accordance with Practice D 585.6.2 A minimum of6gofsample is required to providetriplicate test specimens.6.3 Do not touch the test area of sample or test specimenswith the fingers; handle with cle
18、an forceps only.7. Test Specimens7.1 From each test unit of the sample, cut and weigh2gtothe nearest 1 mg for each test unit.7.2 Determine the moisture content in accordance with TestMethod D 644.METHOD AQUANTITATIVE MEASUREMENT8. Apparatus8.1 Reaction Apparatus (Fig. 1), consisting of a 500-mLround
19、-bottom three-necked flask as illustrated, equipped with agas inlet tube adapter with perforated bulb, a 60-mL pear-shaped funnel, a 200-mm West condenser, a side-arm adapter,and a heating mantle with variable power supply.8.2 Absorption Apparatus (Fig. 1), consisting of a 100-mLamber or low-actinic
20、 flask in a suitable ice bath.8.3 Colorimeter or Spectrophotometer to read at 660 to 670nm equipped with 1-in. cells or 25 to 50-mm cuvettes.8.4 Pipets1, 2, 5, and 10-mL serological or bacteriologi-cal (blow-out).8.5 Other Equipment100 and 1000-mL volumetric flasks;medicine droppers; 10 and 100-mL g
21、raduated cylinders; for-ceps; 10.0-mL volumetric pipets.8.6 DisintegratorA blender or other such rotating-bladedevice with a small volume container, if possible.8.7 Optional EquipmentA constant-temperature bath,maintained at 20 to 25C.9. Reagents and Materials9.1 Purity of ReagentsReagent grade chem
22、icals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents shall conform to the specifications of the Commit-tee on Analytical Reagents of the American Chemical Society,where such specifications are available.6Other grades may beused, provided it is first ascertaine
23、d that the reagent is ofsufficiently high purity to permit its use without lessening theaccuracy of the determination.9.2 Purity of WaterUnless otherwise indicated, referencesto water shall be understood to mean distilled water.9.3 Aluminum Foil, 1145 alloy, plain (or aluminum weigh-ing pans), not o
24、ver 0.01 in. (0.25 mm) sulfur-free.9.4 Amine Solutions:9.4.1 Stock Amine SolutionDissolve 25 g ofp-aminodimethylaniline sulfate (N,N-dimethyl-p-phenylenediamine sulfate) in 75 mL of cold sulfuric acid(1 + 1) and dilute to 100 mL with the (1 + 1) acid.9.4.2 Dilute Amine SolutionPipet 2.5 mL of the st
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD98419972002STANDARDTESTMETHODSFORREDUCIBLESULFURINPAPER 测定 纸中可 还原 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-512673.html