1、 MIL-PRF-1/744J 17 January 2012 SUPERSEDING MIL-PRF-1/744H 12 July 1999 PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, KLYSTRON TYPE 6BM6 * This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the electron tube described
2、herein shall consist of this document and the latest issue of MIL-PRF-1. DESCRIPTION: Reflex, separate cavity, pulse, and CW operation. ABSOLUTE RATINGS: Parameter: Unit: Ef V Ec1 V dc Ec2 V dc Ec3 V dc Er V dc Ik mA dc Ehk V dc Pi W tk sec Alt ft Maximum Minimum 6.9 5.7 +1.0 -500 350 - 350 - -700 -
3、15 32 - +45 -45 10 - - 120 10,000 - PHYSICAL CHARACTERISTICS: Dimensions: Cathode: Mounting position: See figure 1 Coated unipotential Any TEST CONDITIONS: Parameter: Unit: Ef V Ec1 V dc Ec2 V dc Ec3 V dc Er V dc Test condition 1: Test condition 2: 6.3 6.3 0 0 325 300 325 300 Adj for max Po Adj for
4、max Po See footnotes at end of table I. _ GENERAL: Qualification: Not required. This specification sheet uses accept on zero defect sampling in accordance with MIL-PRF-1, table III. _ * CAUTION: Tube not designed for applications where hysteresis may affect performance. AMSC N/A FSC 5960 INCH-POUND
5、Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-1/744J 2 TABLE I. Testing and inspection. Method Limits Inspection MIL-STD-1311 Notes Test Conditions Symbol Min Max Unit Conformance inspection, part 1 Total reflector current (1) 4229 3/ - Er
6、= -90 V dc Ir - 5 A dc Heater current 1301 - - If 500 750 mA Heater-cathode leakage 1336 - - Ehk = 45 V dc Ihk 0 75 A dc Electrode current (1) (cathode) 1256 4/ 1 Ik 13 29 mA dc Reflector voltage (1) 4213 4/ 1 Er -30 -70 V dc Total reflector current (2) 4229 4/ 1 Ir - 150 A dc Frequency (1) - 4/ 1 F
7、 785 815 MHz Power output (1) 4250 4/ 1 Po 50 - mW Cathode emission (1) 4214 4/ 5/ 1 Ikik - 15 % Electrode current (2) (cathode) 1256 6/ 1 Ik 13 29 mA dc Reflector voltage (2) 4213 6/ 1 Er -450 -550 V dc Frequency (2) - 6/ 1 F 2,150 2,250 MHz Power output (2) 4250 6/ 1 Po 50 - mW Cathode emission (2
8、) 4214 5/ 6/ 1 Ikik - 15 % Electrode current (3) (cathode) 1256 7/ 2 Ik 13 29 mA dc Reflector voltage (3) 4213 7/ 2 Er -20 -60 V dc Total reflector current (3) 4229 7/ 2 Ir - 150 A dc Frequency (3) - 7/ 2 F 1,130 1,170 MHz Power output (3) 4250 7/ 2 Po 10 - mW Cathode emission (3) 4214 5/ 7/ 2 Ikik
9、- 15 % Electrode current (4) (cathode) 1256 8/ 2 Ik 13 29 mA dc Reflector voltage (4) 4213 8/ 2 Er -275 -355 V dc Frequency (4) - 8/ 2 F 2,680 2,820 MHz Power output (4) 4250 8/ 2 Po 20 - mW Cathode emission (4) 4214 5/ 8/ 2 Ikik - 15 % See footnotes at end of table. Provided by IHSNot for ResaleNo
10、reproduction or networking permitted without license from IHS-,-,-MIL-PRF-1/744J 3 TABLE I. Testing and inspection - Continued. Method Limits Inspection MIL-STD-1311 Notes Test Conditions Symbol Min Max Unit Conformance inspection, part 2 Secureness of base, cap, or insert 1101 2/ - - - - - Low-freq
11、uency vibration 1031 - - No voltages - - - - Conformance inspection, part 3 Life test - 1/ 1 Group C t 500 - hrs Life-test end points: Power output (3) Power output (4) - 4250 4250 7/ 8/ 2 2 Po Po 8 16 - - mW mW 1/ Test tube with 1,000 MHz test cavity as specified on Drawing 166-JAN. Frequency appro
12、ximately 1,000 MHz. Tube operated in N = 1 mode (1.75 cycles for complete transit). Adjust Er for maximum power output. Adjust output coupling loop for maximum power output. 2/ Water-immersion test omitted. Torque shall be applied between upper disk (g3) and molded portion of base and shall be 20 in
13、ch-pounds. 3/ Static test; tube not oscillating. 4/ Test tube with 800 MHz test cavity as specified on Drawing 166-JAN. Adjust cavity to resonate at 800.5 MHz with standard plug as specified on Drawing 197-JAN. Tube operated in N = 1 mode (1.75 cycles for complete transit). Adjust Er for maximum pow
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILPRF1744J2012ELECTRONTUBEKLYSTRONTYPE6BM6PDF

链接地址:http://www.mydoc123.com/p-692087.html