DLA MIL-PRF-1 689 G-2012 ELECTRON TUBES CATHODE RAY TYPES 5ADP1 5ADP2 5ADP7 AND 5ADP14.pdf
《DLA MIL-PRF-1 689 G-2012 ELECTRON TUBES CATHODE RAY TYPES 5ADP1 5ADP2 5ADP7 AND 5ADP14.pdf》由会员分享,可在线阅读,更多相关《DLA MIL-PRF-1 689 G-2012 ELECTRON TUBES CATHODE RAY TYPES 5ADP1 5ADP2 5ADP7 AND 5ADP14.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、 MIL-PRF-1/689G 3 February 2012 SUPERSEDING MIL-PRF-1/689F 6 July 1999 PERFORMANCE SPECIFICATION SHEET ELECTRON TUBES, CATHODE RAY TYPES 5ADP1, 5ADP2, 5ADP7 AND 5ADP14 This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring
2、the electron tube described herein shall consist of this document and the latest issue of MIL-PRF-1. DESCRIPTION: Electrostatic deflection and focus with post accelerator. DIMENSIONS AND PIN CONNECTIONS: See figure 1. ABSOLUTE RATINGS: Parameter: Ef Ec1 ed Eb1 Eb2 Eb3 Rg Zd Eb3 Eb2 Ehk Alt Unit: V V
3、 dc v V dc V dc V dc Meg Meg Ratio V dc ft Maximum: All 6.9 0, -200 550 1,100 2,850 6,600 1.5 1.0 2.3 180 50,000 Minimum: P1 5.7 - - - - - - - - - 1,500 1,500 - - - - - - - - - - - - - - - P2, P7, P14 5.7 - - - - - - - - - 1,500 3,000 - - - - - - - - - - - - - - - Test conditions: P1 6.3 Adjust - -
4、- Focus 1,500 3,000 - - - - - - - - - - - - - - - P2, P7 P14 6.3 Adjust - - - Focus 2,000 4,000 - - - - - - - - - - - - - - - _ GENERAL: Qualification - Required. This specification sheet uses accept on zero defect sampling in accordance with MIL-PRF-1, table III. AMSC N/A FSC 5960 INCH-POUND Provid
5、ed by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-1/689G 2 TABLE 1. Testing and inspection. Requirement or Test Method MIL-STD-1311 Type Conditions Symbol Limits Min Limits Max Units Qualification inspection Pressure (implosion) Barometric pressure,
6、reduced Vibration Direct-interelectrode capacitance Neck and bulb alignment (electrostatic types) Cathode illumination Focusing voltage at modulation condition Deflection factor Deflection factor Deflection-factor uniformity Base material insulation quality 1141 1002 5111 1331 5101 5216 5246 5248 52
7、48 5248 1216 All All All All All All P1 P2, P7, P14 P1 P2, P7, P14 P1 P2, P7, P14 All All 87 4 mmHg g1 to all k to all D1 to D2 D3 to D4 D1 to all except D2 D2 to all except D1 D3 to all except D4 D4 to all except D3 1D2; Eb2 = Eb3 = 1,500 V dc 1D2; Eb2 = Eb3 = 2,000 V dc 3D4; Eb2 = Eb3 = 1,500 V dc
8、 3D4; Eb2 = Eb3 = 2,000 V dc - - - - - - Width Cg1 Ck C1D2 C3D4 CD1 CD2 CD3 CD4 dia - - - Eb1 Eb1 DF DF DF DF - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 300 400 32.5 43 24.5 32.5 - - - - - - - - - - - - 1 7.9 5.8 3.1 1.3 6.1 6.1 5.0 5.0 2.25 - - - 515 6
9、90 39.5 53 30.5 40.5 2.0 - - - - - - - - - mm pF pF pF pF pF pF pF pF inch - - - V dc V dc V dc/in. V dc/in. V dc/in. V dc/in. % - - - Conformance inspection, part 1 Bulb, screen and faceplate quality Voltage breakdown Voltage breakdown (electrostatic types) Gas “cross” 5106 5201 5201 5206 All All A
10、ll P1 P2, P7, P14 Light = 15 fL Ib3 = 50 A dc (See note 1) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - See notes at end of table. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-1/689G 3 TABLE 1. Testing and inspec
11、tion -Continued. Requirement or test Method MIL-STD-1311 Type Conditions Symbol Limits Min Limits Max Units Conformance inspection, part 1 -Continued Light output Modulation Modulation Spot position (electrostatic deflection) Spot displacement (leakage) Grid-cutoff voltage Grid No. 1 leakage current
12、 Grid No. 2 leakage current Total scan Pattern distortion 5221 5223 5223 5231 5231 5241 5251 5251 - - - 5103 P1 P1 P2, P7, P14 All All P1 P2, P7, P14 P1 P2, P7, P14 All (See note 1) Light = 15 fL (See note 1) Ib3 = 50 A dc (See note 1) Focused raster light = 15 fL (See note 2) Focused raster Ib3 = 5
13、0 A dc (See note 2) (See note 4) Light Ec Ec - - - displ Eco Eco - - - - - - - - - - - - - - - 15 - - - - - - - - - - - - -34 -45 - - - - - - 4.25 4.25 - - - - - - 45 55 16 10 -56 -75 - - - - - - - - - - - - - - - fL V dc V dc mm mm V dc V dc - - - - - - inch inch - - - Conformance inspection, part2
14、 Secureness of base, cap or insert Heater or filament current Electrode currents (anode No. 1) Electrode currents (cathode) Electrode currents (cathode) Base alignment (electrostatic types) 1101 1301 5201 5201 5201 5101 All All All P1 P2, P7, P14 All Ec1 = 0 Light = 15 fL Ib3 = 50 A dc + 1D2; pin No
15、.5 - - - If Ib1 Ik Ik - - - - - - 540 -15 - - - - - - - - - - - - 660 10 1,000 1,000 - - - - - - mA A dc A dc A dc - - - See notes at end of table. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-1/689G 4 TABLE 1. Testing and Inspection -Cont
16、inued. Requirement or test Method MIL-STD-1311 Type Conditions Symbol Limits Min Limits Max Units Conformance inspection, part 2-Continued. Side terminal alignment (electrostatic types) Neck and base alignment (electrostatic types) Angle between traces Stray light emission (conventional types) Scree
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILPRF1689G2012ELECTRONTUBESCATHODERAYTYPES5ADP15ADP25ADP7AND5ADP14PDF

链接地址:http://www.mydoc123.com/p-692086.html