ASTM D1157-1991(2014) Standard Test Method for Total Inhibitor Content &40 TBC&41 of Light Hydrocarbons《轻质烃总抑制剂含量(TBC)的标准试验方法》.pdf
《ASTM D1157-1991(2014) Standard Test Method for Total Inhibitor Content &40 TBC&41 of Light Hydrocarbons《轻质烃总抑制剂含量(TBC)的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D1157-1991(2014) Standard Test Method for Total Inhibitor Content &40 TBC&41 of Light Hydrocarbons《轻质烃总抑制剂含量(TBC)的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D1157 91 (Reapproved 2014)Standard Test Method forTotal Inhibitor Content (TBC) of Light Hydrocarbons1,2This standard is issued under the fixed designation D1157; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the yea
2、r of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of totalp-tertiary-butylcatechol inhibitor added to polymerization andr
3、ecycle grades of butadiene or to other C4hydrocarbonmixtures containing no phenolic material other than catechol orno oxidized phenolic material other than that derived fromoxidation of catechol. In general, all phenols and their quinoneoxidation products are included in the calculated catecholconte
4、nt. Small amounts of polymer do not interfere. This testmethod is applicable over the range of TBC from 50 to500 mgkg.1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This standard does not purport to address all of thesa
5、fety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:3D1265 Practice for Sampling Li
6、quefied Petroleum (LP)Gases, Manual Method3. Summary of Test Method3.1 The catechol is separated from the butadiene by evapo-ration. The residue is dissolved in water and an excess of ferricchloride is added. The intensity of the yellow-colored complexis compared in a photoelectric colorimeter with
7、that producedby known concentrations of the catechol.4. Significance and Use4.1 p-tertiary-butylcatechol is commonly added to commer-cial butadiene in amounts of 50 to 250 mg/kg as an oxidationinhibitor. This test method is suitable for use by both producersand users of butadiene within the limitati
8、ons described inSection 1.5. Apparatus5.1 PhotometerA sensitive photoelectric photometer ca-pable of producing light of narrow spectral range that ispredominantly blue (425 nm).5.2 Graduates, 100-mL.5.3 Volumetric Flasks, 100-mL; or stoppered graduatedmixing cylinder, 100-mL.5.4 Erlenmeyer Flasks, 2
9、50-mL.5.5 Funnels, 75-mm diameter.5.6 Pipet, 5-mL.6. Reagents6.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents shall conform to the specifications of the Commit-tee on Analytical Reagents of the American Chemical Soci
10、ety,where such specifications are available.4Other grades may beused, provided it is first ascertained that the reagent is ofsufficiently high purity to permit its use without lessening theaccuracy of the determination.6.2 Purity of WaterReferences to water shall be under-stood to mean distilled wat
11、er.6.3 Ferric Chloride, Standard Solution Dissolve 20.0 g offerric chloride (FeCl36H2O) in ethanol (95 %). Add 9.2 mL ofHCl (sp gr 1.19), and then dilute with ethanol (95 %) to1000 mL in a volumetric flask.6.4 p-Tertiary-Butylcatechol, Standard(WarningPotentially hazardous. May cause skin irritation
12、 or burns; can1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products, Liquid Fuels, and Lubricantsand is the direct responsibility ofSubcommittee D02.D0.04 on C4 Hydrocarbons.Current edition approved May 1, 2014. Published July 2014. Originally approvedin 1951. Last p
13、revious edition approved in 2009 as D1157 91 (2009). DOI:10.1520/D1157-91R14.2This test method was derived from the method developed and cooperativelytested by the Butadiene Producers Committee on Specifications and Methods ofAnalysis of the Office of Rubber Reserve, which appears in the ButadieneLa
14、boratory Manual as Method 2.1.9.1.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.4Reagent Chemicals, America
15、n Chemical Society Specifications, AmericanChemical Society, Washington, DC. For Suggestions on the testing of reagents notlisted by the American Chemical Society, see Annual Standards for LaboratoryChemicals, BDH Ltd., Poole, Dorset, U.K., and the United States Pharmacopeiaand National Formulary, U
16、.S. Pharmacopeial Convention, Inc. (USPC), Rockville,MD.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1be absorbed through the skin. May be harmful or fatal ifswallowed. Avoid contact with eyes; may burn and impairvision. May be harm
17、ful to respiratory system. May producequinones and flammable butylenes on decomposition. Use withadequate ventilation. Store in flammable liquids storage area.)Dissolve 0.63 g of p-tertiary-butylcatechol (95 % minimumpurity) in 10 mL of ethanol (95 %) and dilute with water to100 mL in a volumetric f
18、lask. When used in place of 100 mL(63 g) of sample, consider 1.00 mL of this solution to beequivalent to 100 ppm of catechol. This solution is not stableand should be prepared as needed.7. Sampling7.1 Supply samples to the laboratory in high-pressuresample cylinders. Use the procedures described in
19、PracticeD1265 or similar methods.8. Calibration and Standardization8.1 Preparation of Standard SolutionsPrepare a standard-ization curve showing the relation between the absorbance andthe catechol content as follows: Make up solutions of knowncatechol content by pipetting 0, 1, 2, 3, 4, and 5-mLport
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD115719912014STANDARDTESTMETHODFORTOTALINHIBITORCONTENT40TBC41OFLIGHTHYDROCARBONS 轻质烃总 抑制剂 含量 TBC

链接地址:http://www.mydoc123.com/p-509361.html