ASTM C991-2003 Standard Specification for Flexible Glass Fiber Insulation for Metal Buildings《金属建筑物用挠性玻璃纤维绝缘材料标准规范》.pdf
《ASTM C991-2003 Standard Specification for Flexible Glass Fiber Insulation for Metal Buildings《金属建筑物用挠性玻璃纤维绝缘材料标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM C991-2003 Standard Specification for Flexible Glass Fiber Insulation for Metal Buildings《金属建筑物用挠性玻璃纤维绝缘材料标准规范》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 991 03Standard Specification forFlexible Fibrous Glass Insulation for Metal Buildings1This standard is issued under the fixed designation C 991; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revisi
2、on. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers the classification, composition,and physical properties of flexible fibrous glass insulation foruse as
3、 interior surface of walls and roofs of metal buildings.1.2 The basic insulation blanket is designed to be post-processed by a laminating process that applies an adhesivebonded facing to provide the interior finish and vapor retarderrequirements for the building envelope.1.3 The thermal values measu
4、red in accordance with thisspecification for both pre-processed and post-processed insu-lation are for the insulation only and do not include the effectsof air-film surface resistance, changes in mean temperature, orcompression of insulation at the framing members of thebuilding, through metal condu
5、ctance of fasteners and otherparallel heat-transfer paths due to design or installation tech-niques.1.4 The values stated in inch-pound units are to be regardedas the standard. The values given in parentheses are providedfor information only.1.5 This standard does not purport to address all of thesa
6、fety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory requirements prior to use.2. Referenced Documents2.1 ASTM Standards:2C 167 Test Methods for Thickn
7、ess and Density of Blanketor Batt Thermal InsulationsC 168 Terminology Relating to Thermal Insulating Materi-alsC 177 Test Method for Steady-State Heat Flux Measure-ments and Thermal Transmission Properties by Means ofthe Guarded-Hot-Plate ApparatusC 390 Criteria for Sampling and Acceptance of Prefo
8、rmedThermal Insulation LotsC 518 Test Method for Steady-State Heat Flux Measure-ments and Thermal Transmission Properties by Means ofThe Heat Flow Meter ApparatusC 653 Guide for Determination of the Thermal Resistanceof Low-Density Blanket-Type Mineral Fiber InsulationC 665 Specification for Mineral
9、-Fiber Blanket Thermal In-sulation for Light Frame Construction and ManufacturedHousingC 755 Practice for Selection of Vapor Retarders for ThermalInsulationC 1104 Test Method for Determining Water Vapor Sorptionof Unfaced Mineral Fiber Insulation.C 1136 Specification for Flexible, Low Permeance Vapo
10、rRetarders for Thermal InsulationC 1258 Test Method for Elevated Temperature and Humid-ity Resistance of Vapor Retarders for InsulationC 1304 Test Method for Assessing the Odor Emission ofThermal InsulationC 1338 Test Method for Determining Fungi Resistance ofInsulation Materials and FacingsE 84 Tes
11、t Method for Surface Burning Characteristics ofBuilding MaterialsE 96 Test Methods for Water Vapor Transmission of Mate-rialsE 136 Test Method for Behavior of Materials in a VerticalTube Furnace at 7502.2 Other Referenced Document:CAN/ULC-S102M88 Standard Method of Test for SurfaceBurning Characteri
12、stics of Building Materials and Assem-blies33. Terminology3.1 DefinitionsFor definitions of terms relating to insula-tion, refer to Terminology C 168.4. Classification4.1 The flexible insulation is furnished in two types, asfollows:1This specification is under the jurisdiction of ASTM Committee C16
13、onThermal Insulation and is the direct responsibility of Subcommittee C16.23 onBlanket and Loose Fill Insulation.Current edition approved Oct. 1, 2003. Published November 2003. Originallyapproved in 1983. Last previous edition approved in 2000 as C 991 00.2For referenced ASTM standards, visit the AS
14、TM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from Underwriters Laboratories of Canada, 7 Crouse Road, Scarbor-ough, Ontario Canada M1R 3A9.
15、1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4.1.1 Type IGlass processed from the molten state intofibrous form, bonded with a thermosetting resin, and formedinto a resilient flexible blanket or batt.4.1.2 Type IIType I material s
16、upplied with a suitablefacing adhered to one surface.5. Ordering Information5.1 Type I material shall be ordered by specifying thermalresistance value, length, and width.5.2 Type II material shall be ordered by specifying thermalresistance value, type of facing, facing permeance, length,width, numbe
17、r of tabs, and tab width.5.3 Certification, when required, shall be in accordance withSection 11.6. Physical Properties6.1 Type 1 Material:6.1.1 Thermal ResistanceThe thermal resistance of thepre-processed insulation shall be determined in accordancewith Guide C 653. The average R-value from nine ra
18、ndomlyselected specimens, three specimens from each of three rolls,shall not be less than 103 % of the R-value agreed upon by thepurchaser and the supplier. Use Test Method C 177 or C 518 at75F (23.9C) with a minimum temperature difference of 40F(20C) for determining apparent thermal conductivity. U
19、se thefull roll method from Test Method C 167 to determine theaverage thickness for each roll and evaluate at the lesser ofmeasured or label thickness.NOTE 1See Guide C 653. The thermal resistance is a function ofmean temperature. As an option, the thermal resistance may be determinedat additional m
20、ean temperatures as agreed upon by the purchaser and themanufacturer.6.1.2 Surface Burning CharacteristicsThe surface burn-ing characteristics shall be determined in accordance with TestMethod E 84. For Canada, test in accordance with CAN/ULC-S102-M88. Results shall be no greater than:Flame spread 2
21、5Smoke developed 506.1.3 Combustion CharacteristicsThe material shall passthe requirements of Test Method E 136.6.1.4 Water Vapor SorptionThe water vapor sorptionfrom exposure to water vapor shall not be greater than 0.2 % byvolume when determined in accordance with the procedure setforth in Test Me
22、thod C 1104.6.1.5 Fungi ResistanceWhen tested in accordance withthe procedure set forth in Test Method C 1338, the insulationshall exhibit no growth.6.1.6 CorrosivenessWhen tested in accordance with theprocedure in Specification C 665, the metal plates in contactwith the insulation shall show no gre
23、ater corrosion than thatobserved on the comparative plates in contact with sterilecotton.6.1.7 Odor EmissionWhen tested in accordance with TestMethod C 1304, the insulation shall not emit a detectable odorobjectionable to more than two of the five panel members.6.1.8 Dimensional TolerancesThe averag
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC9912003STANDARDSPECIFICATIONFORFLEXIBLEGLASSFIBERINSULATIONFORMETALBUILDINGS 金属 建筑物 用挠性 玻璃纤维 绝缘材料

链接地址:http://www.mydoc123.com/p-509081.html