ASTM C915-1979(2002) Standard Specification for Precast Reinforced Concrete Crib Wall Members《预制钢筋混凝土框架墙构件》.pdf
《ASTM C915-1979(2002) Standard Specification for Precast Reinforced Concrete Crib Wall Members《预制钢筋混凝土框架墙构件》.pdf》由会员分享,可在线阅读,更多相关《ASTM C915-1979(2002) Standard Specification for Precast Reinforced Concrete Crib Wall Members《预制钢筋混凝土框架墙构件》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 915 79 (Reapproved 2002)Standard Specification forPrecast Reinforced Concrete Crib Wall Members1This standard is issued under the fixed designation C 915; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of l
2、ast revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers open- and closed-face precastreinforced concrete crib walls intended to act as earth-retaini
3、ngstructures or as protection against stream encroachment.NOTE 1This specification is a manufacturing and purchase specifica-tion only, with examples and suggestions for usage. Successful perfor-mance of this product depends on the proper selection and assembling ofmembers, proper foundation and bea
4、ring material, and consideration ofbackfill heights, backfill material, drainage, and other engineering andconstruction considerations. The purchaser of the crib wall membersspecified herein is cautioned that he must properly correlate the fieldrequirements with the members selected and provide adeq
5、uate inspectionat the construction site.1.2 The values stated in inch-pound units are to be regardedas the standard. The values given in parentheses are forinformation only.2. Referenced Documents2.1 ASTM Standards:A 370 Test Methods and Definitions for Mechanical Testingof Steel Products2A 615/A 61
6、5M Specification for Deformed and PlainBillet-Steel Bars for Concrete Reinforcement3A 616/A 616M Specification for Rail-Steel Deformed andPlain Bars for Concrete Reinforcement4A 617/A 617M Specification for Axle-Steel Deformed andPlain Bars for Concrete Reinforcement4C 31/C 31M Practice for Making a
7、nd Curing Concrete TestSpecimens in the Field5C 33 Specification for Concrete Aggregates5C 39/C 39M Test Method for Compressive Strength of Cy-lindrical Concrete Specimens5C 42/C 42M Test Method for Obtaining and Testing DrilledCores and Sawed Beams of Concrete5C 94/C 94M Specification for Ready-Mix
8、ed Concrete5C 150 Specification for Portland Cement6C 173/C 173M Test Method for Air Content of FreshlyMixed Concrete by the Volumetric Method5C 231 Test Method for Air Content of Freshly MixedConcrete by the Pressure Method5C 260 Specification for Air-Entraining Admixtures for Con-crete5C 309 Speci
9、fication for Liquid Membrane-Forming Com-pounds for Curing Concrete5C 330 Specification for Lightweight Aggregates for Struc-tural Concrete5C 494/C 494M Specification for Chemical Admixtures forConcrete5C 595 Specification for Blended Hydraulic Cements6C 618 Specification for Coal Fly Ash and Raw or
10、 CalcinedNatural Pozzolan for Use as a Mineral Admixture inConcrete53. Classification3.1 Cribbing manufactured in accordance with this specifi-cation shall be of open- or closed-face design and shallconform to the standard designs shown in Figs. 1-4.4. Ordering Information4.1 Acceptability of the cr
11、ib wall members in all crosssections and lengths produced in accordance with Section 6shall be determined by the results of cylinder compression testsof the placed concrete and mill certificates for the reinforcingsteel and cement. A written statement, signed by the manufac-turer, shall verify that
12、the cement, aggregate, admixtures, andreinforcing steel conform to the specifications for materials inSection 5 and that the preparation of equipment, mixing,conveying, placing, consolidating, and curing meet require-ments of the applicable standard specifications. The concretestrength as determined
13、 by the cylinder compression tests shallbe as specified in 6.3, and the test method shall conform to therequirements of Test Method C 39. The manufacturers state-ment shall also certify adherence to tolerance dimensions ofSection 9.4.2 Acceptability of the concrete strength of completedcribbing prod
14、uced in accordance with Section 6 may also be1This specification is under the jurisdiction of ASTM Committee C27 on PrecastConcrete Products and is the direct responsibility of Subcommittee C27.20 onArchitectural and Structural Products.Current edition approved Nov. 5, 1979. Published January 1980.2
15、Annual Book of ASTM Standards, Vol 01.03.3Annual Book of ASTM Standards, Vol 01.04.4Discontinued; see 1998 Annual Book of ASTM Standards, Vol 01.04. Replacedby A 996/A 996M.5Annual Book of ASTM Standards, Vol 04.02.6Annual Book of ASTM Standards, Vol 04.01.1Copyright ASTM International, 100 Barr Har
16、bor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.determined by compressive tests of concrete cores in accor-dance with Test Method C 42.5. Materials5.1 CementPortland cement shall conform to the require-ments of Specification C 150 or shall be portland blast-furnaceslag cement
17、 or portland-pozzolan cement conforming to therequirements of Specification C 595.5.2 AggregatesAggregates shall conform to SpecificationC 33 or C 330. The nominal maximum size aggregate shall notbe greater than34 in. (19.0 mm).5.3 AdmixturesAir-entraining admixtures shall conformto Specification C
18、260. Chemical admixtures shall conform toSpecification C 494. Fly ash or other pozzolanic admixturesshall conform to the requirements of Specification C 618.5.4 WaterWater used for curing, washing aggregates, andmixing concrete shall be free of oils, organic materials, andother substances that may b
19、e deleterious to concrete or steel; itshould not contain concentrations of chlorides in excess of1000 ppm or sulfates in excess of 1000 ppm.5.4.1 If water of higher chloride content is used by reason ofnonavailability of water of recommended quality, the manu-facturer must obtain approval from the u
20、ser.5.5 Steel ReinforcementSteel reinforcement shall consistof bars conforming to Specifications A 615/A 615M, A 616/A 616M, or A 617/A 617M.6. Design6.1 Precast concrete crib wall members shall conform todetails and dimensions prescribed in Figs. 1-4, subject to theprovisions of this section and Se
21、ction 10.6.2 ReinforcementMinimum reinforcement shall be asshown in Fig. 2 and Fig. 4 and shall be Grade 40 or 60.6.3 ConcreteConcrete shall have a minimum design com-pressive strength of 4000 psi (28 MPa) in 28 days.6.4 Concrete CoverThe minimum concrete cover over thereinforcement shall be 114 in.
22、 (32 mm).6.5 Air EntrainmentUnless otherwise specified by thepurchaser, all concrete shall have an air content of 612 6 112 %as measured by Test Method C 173 or C 231.NOTE 1Surface drainage should not be permitted to flow directly against the face of the cribbing.NOTE 2Walls should be separated into
23、 96-ft sections by the provision of double rows of headers.NOTE 3In using these typical sections for designing walls of intermediate height, the drawing should be read from the top down until the desiredheight is reached. Base details are repeated for intermediate heights.NOTE 4In areas of aggressiv
24、e environment, Type II cement or protective coatings, or both, may need to be used to avoid deterioration of the walls.NOTE 5Metric Conversion: 1 ft = 304.8 1 in. = 25.4 mm 1 lb = 0.453592 kg 1 ft3= 0.028317 m3FIG. 1 Open-Faced Concrete Crib WallC 915 79 (2002)27. Manufacture7.1 CertificationAt the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC91519792002STANDARDSPECIFICATIONFORPRECASTREINFORCEDCONCRETECRIBWALLMEMBERS 预制 钢筋混凝土 框架 构件 PDF

链接地址:http://www.mydoc123.com/p-508780.html