1、Designation: C91/C91M 12C91/C91M 18Standard Specification forMasonry Cement1This standard is issued under the fixed designation C91/C91M; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parent
2、heses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope1.1 This specification covers three types of masonry cement for use w
3、here mortar for masonry is required.1.2 UnitsThe values stated in either SI units or inch-pound units are to be regarded separately as standard. The values statedin each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining valuesfrom the two
4、 systems may result in non-conformance with the standard. Values in SI units shall be obtained by measurement inSI units or by appropriate conversion, using the Rules for Conversion and Rounding given in Standard IEEE/ASTM SI 10, ofmeasurements made in other units. Values are stated in only SI units
5、 when inch-pound units are not used in practice.1.3 The text of this standard refers to notes and footnotes which provide explanatory material. These notes and footnotes(excluding those in tables and figures) shall not be considered as requirements of the standard.1.4 The following safety hazards ca
6、veat pertains only to Sections 16 and 17 of this specification. This standard does not purportto address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establishappropriate safety safety, health, and healthenvironmental practices
7、 and determine the applicability of regulatory limitations priorto use. (WarningFresh hydraulic cementitious mixtures are caustic and may cause chemical burns to skin and tissue uponprolonged exposure.)21.5 This international standard was developed in accordance with internationally recognized princ
8、iples on standardizationestablished in the Decision on Principles for the Development of International Standards, Guides and Recommendations issuedby the World Trade Organization Technical Barriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:3C109/C109M Test Method for Compres
9、sive Strength of Hydraulic Cement Mortars (Using 2-in. or 50-mm Cube Specimens)C151 Test Method for Autoclave Expansion of Hydraulic CementC183 Practice for Sampling and the Amount of Testing of Hydraulic CementC185 Test Method for Air Content of Hydraulic Cement MortarC187 Test Method for Amount of
10、 Water Required for Normal Consistency of Hydraulic Cement PasteC188 Test Method for Density of Hydraulic CementC219 Terminology Relating to Hydraulic CementC266 Test Method for Time of Setting of Hydraulic-Cement Paste by Gillmore NeedlesC270 Specification for Mortar for Unit MasonryC305 Practice f
11、or Mechanical Mixing of Hydraulic Cement Pastes and Mortars of Plastic ConsistencyC430 Test Method for Fineness of Hydraulic Cement by the 45-m (No. 325) SieveC511 Specification for Mixing Rooms, Moist Cabinets, Moist Rooms, and Water Storage Tanks Used in the Testing of HydraulicCements and Concret
12、esC778 Specification for Standard SandC1506 Test Method for Water Retention of Hydraulic Cement-Based Mortars and PlastersIEEE/ASTM SI 10 Standard for Use of the International System of Units (SI): The Modern Metric System1 This specification is under the jurisdiction of ASTM Committee C01 on Cement
13、 and is the direct responsibility of Subcommittee C01.11 on Masonry Cement.Current edition approved April 1, 2012March 1, 2018. Published May 2012April 2018. Originally approved in 1932. Last previous edition approved in 20052012 asC91C91/C91M 12. 05. DOI: 10.1520/C0091-12.10.1520/C0091_C0091M-18.2
14、Annual Book of ASTM Standards, Vol 04.01. See the section on Safety Precautions in the Manual of Cement Testing.3 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the s
15、tandards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accur
16、ately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United Stat
17、es13. Terminology3.1 Definitions:3.1.1 masonry cementa hydraulic cement, primarily used in masonry and plastering construction, consisting of a mixture ofportland or blended hydraulic cement and plasticizing materials (such as limestone, hydrated or hydraulic lime) together with othermaterials intro
18、duced to enhance one or more properties such as setting time, workability, water retention, and durability.3.1.1 masonry cement, na hydraulic cement, primarily used in masonry and plastering construction, consisting of a mixtureof portland or blended hydraulic cement and plasticizing materials (such
19、 as limestone, hydrated or hydraulic lime) together withother materials introduced to enhance one or more properties such as setting time, workability, water retention, and durability.3.1.2 Other terms used in this specification are defined in Terminology C219.4. Classification4.1 Type NFor use in p
20、reparation of Specification C270 Type N mortar without further addition of cements or hydrated lime,and for use in preparation of Specification C270 Type S or Type M mortar when cement is added in accordance with therequirements of C270.4.2 Type SFor use in preparation of Specification C270 Type S m
21、ortar without further addition of cements or hydrated lime.4.3 Type MFor use in preparation of Specification C270 Type M mortar without further addition of cements or hydrated lime.5. Physical Properties5.1 Masonry cement shall conform to the applicable requirements prescribed in Table 1 for its cla
22、ssification.6. Sampling6.1 The masonry cement shall be sampled in accordance with Practice C183.7. Temperature and Humidity7.1 The temperature and relative humidity of the air in the vicinity of the mixing slab and dry materials, molds, base plates, andmixing bowl shall conform to the requirements o
23、f Test Method C109/C109M.7.2 The moist cabinet or moist room shall conform to the requirements of Specification C511.8. Fineness8.1 Determine the residue on the 45-m (No. 325) sieve in accordance with Test Method C430.9. Normal Consistency9.1 Determine normal consistency by the Vicat apparatus in ac
24、cordance with Test Method C187.10. Autoclave Expansion10.1 Determine autoclave expansion in accordance with Test Method C151. After molding, store the bars in the moist cabinetor room for 48 h 6 30 min before removal from the molds for measurement and testing in the autoclave. Calculate the differen
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC91C91M2018STANDARDSPECIFICATIONFORMASONRYCEMENT 砌筑 水泥 标准规范 PDF

链接地址:http://www.mydoc123.com/p-508761.html