ASTM C700-2018 Standard Specification for Vitrified Clay Pipe Extra Strength Standard Strength and Perforated.pdf
《ASTM C700-2018 Standard Specification for Vitrified Clay Pipe Extra Strength Standard Strength and Perforated.pdf》由会员分享,可在线阅读,更多相关《ASTM C700-2018 Standard Specification for Vitrified Clay Pipe Extra Strength Standard Strength and Perforated.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C700 18Standard Specification forVitrified Clay Pipe, Extra Strength, Standard Strength, andPerforated1This standard is issued under the fixed designation C700; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year
2、of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope1.1 This specification establishe
3、s the criteria for acceptance,prior to installation, of extra strength and standard strengthvitrified clay pipe and fittings to be used for the conveyance ofsewage, industrial wastes, and storm water; and extra strengthperforated and standard strength perforated vitrified clay pipeto be used for und
4、erdrainage, filter fields, leaching fields, andsimilar subdrainage installations.1.2 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.NOTE
5、 1Attention is called to Specification C425, Test Method C828,Test Method C1091, Test Methods C301, and Terminology C896.1.3 The following precautionary caveat pertains only to theTest Method portion, 5.2 5.2.3.2 of this standard: Thisstandard does not purport to address all of the safety concerns,i
6、f any, associated with its use. It is the responsibility of the userof this standard to establish appropriate safety, health, andenvironmental practices and determine the applicability ofregulatory limitations prior to use.1.4 This international standard was developed in accor-dance with internation
7、ally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2C301 Test M
8、ethods for Vitrified Clay PipeC425 Specification for Compression Joints for Vitrified ClayPipe and FittingsC828 Test Method for Low-Pressure Air Test of VitrifiedClay Pipe LinesC896 Terminology Relating to Clay ProductsC1091 Test Method for Hydrostatic Infiltration Testing ofVitrified Clay Pipe Line
9、s3. Terminology3.1 DefinitionsClay, fire clay, shale, and surface clay areas defined in Terminology C896.4. Materials and Manufacture4.1 Vitrified clay pipe shall be manufactured from fire clay,shale, surface clay, or a combination of these materials that,when formed into pipe and fired to suitable
10、temperatures,yields a product that conforms to this specification.5. Physical Properties5.1 Bearing Strength:5.1.1 Pipe shall meet the bearing strength requirements ofTable 1.5.1.2 The number of specimens to be tested shall not exceed0.5 % of the number of pipe of each size furnished, except thatno
11、less than two specimens shall be tested.5.1.3 If any of the test specimens fail to meet therequirements, the manufacturer will be allowed a retest on twoadditional specimens for each one that failed. The pipe will beacceptable if all the retest specimens meet the test requirement.5.1.4 If, subsequen
12、t to an initial pipe strength failure, theaccuracy of the testing equipment is questioned, at the requestof the manufacturer, the equipment shall be recalibrated and aretest made or a retest made upon equipment of knownaccuracy.5.2 Hydrostatic Pressure Test or Absorption Test:5.2.1 The manufacturer
13、shall at his option, apply either ahydrostatic pressure test or an absorption test to all of the testspecimens in each size and run of the pipe.5.2.2 Hydrostatic Pressure Test:5.2.2.1 When the pipe is subjected to an internal hydrostaticpressure of 10 psi (68.9 KPa) for the elapsed time shown in the
14、1This specification is under the jurisdiction of ASTM Committee C04 onVitrified Clay Pipe and is the direct responsibility of Subcommittee C04.20 onMethods of Test and SpecificationsCurrent edition approved Sept. 1, 2018. Published September 2018. Originallyapproved in 1971. Last previous edition ap
15、proved in 2013 as C700 13. DOI:10.1520/C0700-18.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright AST
16、M International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Stan
17、dards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.1following table, there shall be no leaking on the exterior of thepipe. Moisture appearing on the surface of the pipe in the formof beads adhering to the surface shall not be consider
18、edleakage. However, moisture which starts to run on the pipeshall be construed as leakage regardless of quantity.Hydrostatic Pressure Test TimeThickness of Barrelin. (mm)Test Time (min.)Up to and including 1 (25) 7Over 1 (25) including 112 (38) 9Over 112 (38) including 2 (51) 12Over 2 (51) including
19、 212 (64) 15Over 212 (64) including 3 (76) 18Over 3 (76) 215.2.2.2 If any of the test specimens fail to meet the Hydro-static Pressure Test requirements, a retest will be allowed andthe pipe accepted as provided in 5.1.3.5.2.3 Absorption Test:5.2.3.1 The absorption of vitrified clay pipe shall not e
20、xceed8%.5.2.3.2 If any of the test specimens fail to meet the absorp-tion requirements, a retest will be allowed and the pipeaccepted as provided in 5.1.3.5.3 Acid Resistance:5.3.1 This test is used to determine the resistance of pipe tothe action of acids encountered in sanitary sewers. Test result
21、sshall be provided when requested.5.3.2 Test specimens shall be representative of the materialof the pipe supplied.5.3.3 The loss of material from the test specimen shall notexceed 0.25%.5.3.4 The test shall be in accordance with Test MethodsC301.5.3.5 If any of the test specimens fail to meet the a
22、cidresistance requirements, the manufacturer will be allowed toretest two additional specimens. The pipe will be acceptable ifall retest specimens meet the test requirements.6. Allowable Limits for Dimensional Variation6.1 Sizes and dimensions of pipe are as described in Table2.6.2 The inside diamet
23、er shall not vary from a true circle bymore than 3 % of its nominal diameter measured at any onelocation along the pipe barrel.6.3 The average inside diameter shall be determined bytaking any two 90 (1.6-rad) opposing measurements andaveraging the readings.7. Straightness7.1 Pipe shall not deviate f
24、rom straight by more than116in./ft (5 mm/m) of length when the maximum offset ismeasured from the concave side of the pipe.7.2 Measurement shall be taken by placing a straightedge onthe concave side of the full length of the pipe barrel, excludingthe spigot joint material or socket, and measuring th
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC7002018STANDARDSPECIFICATIONFORVITRIFIEDCLAYPIPEEXTRASTRENGTHSTANDARDSTRENGTHANDPERFORATEDPDF

链接地址:http://www.mydoc123.com/p-508058.html