BS PD CLC TR 50126-3-2008 Railway applications —The specification and ndemonstration of Reliability Availability nMaintainability and Safety (RAMS) — nPart 3 Guide to th.pdf
《BS PD CLC TR 50126-3-2008 Railway applications —The specification and ndemonstration of Reliability Availability nMaintainability and Safety (RAMS) — nPart 3 Guide to th.pdf》由会员分享,可在线阅读,更多相关《BS PD CLC TR 50126-3-2008 Railway applications —The specification and ndemonstration of Reliability Availability nMaintainability and Safety (RAMS) — nPart 3 Guide to th.pdf(66页珍藏版)》请在麦多课文档分享上搜索。
1、PUBLISHED DOCUMENT PD CLC/TR 50126-3:2008 Railway applications The specification and demonstration of Reliability, Availability, Maintainability and Safety (RAMS) Part 3: Guide to the application of EN 50126-1 for rolling stock RAM ICS 29.280; 45.020 PD CLC/TR 50126-3:2008 This Published Document wa
2、s published under the authority of the Standards Policy and Strategy Committee on 30 September 2008 BSI 2008 ISBN 978 0 580 61845 1 National foreword This Published Document is the UK implementation of CLC/TR 50126-3:2008. It supersedes PD CLC/TR 50126-3:2006 which is withdrawn. The UK participation
3、 in its preparation was entrusted by Technical Committee GEL/9, Railway electrotechnical applications, to Subcommittee GEL/9/2, Rolling stock. A list of organizations represented on this committee can be obtained on request to its secretary. This publication does not purport to include all the neces
4、sary provisions of a contract. Users are responsible for its correct application. Amendments/corrigenda issued since publication Date Comments TECHNICAL REPORT CLC/TR 50126-3 RAPPORT TECHNIQUE TECHNISCHER BERICHT July 2008 CENELEC European Committee for Electrotechnical Standardization Comit Europen
5、 de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2008 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. CLC/TR 50126-3:2008 E ICS 29.280; 45.
6、020 Supersedes CLC/TR 50126-3:2006English version Railway applications The specification and demonstration of Reliability, Availability, Maintainability and Safety (RAMS) Part 3: Guide to the application of EN 50126-1 for rolling stock RAM Applications ferroviaires Spcification et dmonstration de la
7、 Fiabilit, de la Disponibilit, de la Maintenabilit et de la Scurit (FDMS) Partie 3: Guide pour lapplication de la EN 50126-1 la fiabilit, la disponibilit, la maintenabilit et la scurit du matriel roulant Bahnanwendungen Spezifikation und Nachweis der Zuverlssigkeit, Verfgbarkeit, Instandhaltbarkeit,
8、 Sicherheit (RAMS) Teil 3: Leitfaden zur Anwendung der EN 50126-1 fr Bahnfahrzeuge RAM This Technical Report was approved by CENELEC on 2008-05-09. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Franc
9、e, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. Foreword This Technical Report was prepared by Working Group B11 of SC 9XB, Electrome
10、chanical material on board of rolling stock, of Technical Committee CENELEC TC 9X, Electrical and electronic applications for railways. The text of the draft was submitted to the vote and was approved by CENELEC as CLC/TR 50126-3 on 2008-05-09. This Technical Report supersedes CLC/TR 50126-3:2006. T
11、his Technical Report forms an informative part of EN 50126 and contains guidelines for the application of EN 50126-1 to Rolling Stock RAM. _ 2 CLC/TR 50126-3:2008 Contents Page Introduction 6 1 Scope . 7 2 Definitions 7 3 Approach adopted for the Guide 8 3.1 General 8 3.2 Entities Involved In the Li
12、fe Cycle Phases of Rolling Stock 8 4 Application of this Guide 8 4.1 Object of the application 8 4.2 Application of EN 50126-1 9 4.2.1 Assessment of the application of EN 50126-1 9 4.2.2 Mandatory requirements for the application of EN 50126-1 . 9 5 Specifying RAM requirements . 10 5.1 Introduction
13、. 10 5.2 Preliminary RAM analysis . 10 5.2.1 General . 10 5.2.2 Preliminary RAM Analysis activities 10 5.2.2.1 General 10 5.2.2.2 System Identification . 11 5.2.2.3 Breakdown structure and boundary limits 12 5.2.2.4 Failure Conditions . 14 5.3 RAM requirements 16 5.3.1 Introduction . 16 5.3.2 Reliab
14、ility Targets . 16 5.3.3 Maintainability Targets 18 5.3.3.1 Generic Qualitative Requirements for Maintainability 18 5.3.3.2 Preventive/Corrective Maintenance Requirements . 20 5.3.3.3 Logistic Support Requirements . 20 5.3.3.4 Maintenance Cost Requirements 21 5.3.4 Availability Targets 21 5.4 Proces
15、s for choosing RAM figures 24 5.5 RAM Programme 24 5.5.1 Introduction . 24 5.5.2 Configuration Management System . 25 5.5.3 RAM Programme Outline 25 5.5.4 Example of RAM Analyses Document Template and Data 26 5.5.4.1 Introduction 26 5.5.4.2 Common Data for the analyses 26 5.5.4.3 Reliability Predict
16、ion Analysis Template and Data Sheets . 27 5.5.4.4 Maintenance Attributes (Maintenance Levels, Skill Level and LRU definition) 29 5.5.4.5 Preventive Maintenance Analysis Template and Data Sheets 31 5.5.4.6 Corrective Maintenance Analysis Template and Data Sheets 35 5.5.4.7 Failure Mode Effects and C
17、riticality Analysis Template and Data Sheets 37 3 CLC/TR 50126-3:20086 RAM Assurance during Life Cycle . 40 6.1 RAM Programme and Phases of the Life Cycle . 40 6.1.1 Introduction . 40 6.1.2 Tender Phase . 41 6.1.3 Design Phase 42 6.1.4 Demonstration Phase . 44 6.1.4.1 Introduction 44 6.1.4.2 RAM Acc
18、eptance Criteria . 45 6.1.4.3 In service checking Period . 45 6.1.4.4 Data Report from field and its organisation 46 7 RAM Parameters to be incorporated into LCC Model . 47 7.1 Introduction . 47 7.2 Overview of LCC Modelling 47 7.3 RAM parameters for LCC 48 Annex A Examples of breakdown structure .
19、49 Bibliography . 62 Figures Figure 1 Example of Reliability Prediction Analysis Sheet . 28 Figure 2 Example of Preventive Maintenance Analysis Sheet 32 Figure 3 Example of Preventive Maintenance Sheet for a single frequency . 34 Figure 4 Example of Corrective Maintenance Analysis Sheet . 36 Figure
20、5 Example of items FMECA Sheet 38 Figure 6 Example of functions FMECA Sheet 39 Figure 7 RAM Programme and Life Cycle Phases 40 Figure 8 Possible relationships between Customer, Main Supplier, Sub-Supplier during some phases of Life Cycle for rolling stock . 41 Figure 9 Flow diagram representing acti
21、vities/documentations of Design Phase 42 Figure A.1 Example of physical structure using organisation chart for an Electrical Multiple Unit Coach . . 50 Figure A.2 Example of functional structure using organisation chart for an Electrical Multiple Unit Coach . . 51 Figure A.3 Example of structure usi
22、ng the tree breakdown chart for an EMU (Electrical Multiple Unit) Traction Vehicle . 58 Figure A.4 Example of structure using the tree breakdown chart for an EMU (Electrical Multiple Unit) Coach . . 61 4 CLC/TR 50126-3:2008 Tables Table 1 Possible sharing of responsibility 8 Table 2 Example of minim
23、um set of data of the header for a form representing a breakdown structure . 13 Table 3 Example of minimum set of data representing a breakdown structure . 14 Table 4 RAM Failure Categories 14 Table 5 Significant Failure Specification 15 Table 6 Major Failure Specification 16 Table 7 Minor Failure S
24、pecification 16 Table 8 Reliability Requirements for Failure Categories 17 Table 9 Qualitative Requirements for Maintainability . 18 Table 10 Preventive/Corrective Maintenance Requirements . 20 Table 11 Logistic Support Requirements . 20 Table 12 Maintenance Cost Requirements 21 Table 13 Availabilit
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSPDCLCTR5012632008RAILWAYAPPLICATIONSTHESPECIFICATIONANDNDEMONSTRATIONOFRELIABILITYAVAILABILITYNMAINTAINABILITYANDSAFETYRAMSNPART3GUIDETOTHPDF

链接地址:http://www.mydoc123.com/p-397557.html