ASTM C1332-2018 Standard Practice for Measurement of Ultrasonic Attenuation Coefficients of Advanced Ceramics by Pulse-Echo Contact Technique《用脉冲回波接触技术测量高级陶瓷超声衰减系数的标准实施规程》.pdf
《ASTM C1332-2018 Standard Practice for Measurement of Ultrasonic Attenuation Coefficients of Advanced Ceramics by Pulse-Echo Contact Technique《用脉冲回波接触技术测量高级陶瓷超声衰减系数的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1332-2018 Standard Practice for Measurement of Ultrasonic Attenuation Coefficients of Advanced Ceramics by Pulse-Echo Contact Technique《用脉冲回波接触技术测量高级陶瓷超声衰减系数的标准实施规程》.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1332 01 (Reapproved 2013)C1332 18Standard Test Method Practice forMeasurement of Ultrasonic Attenuation Coefficients ofAdvanced Ceramics by Pulse-Echo Contact Technique1This standard is issued under the fixed designation C1332; the number immediately following the designation indicates
2、 the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope Scope*1.1 This test method practice describes a pr
3、ocedure for measurement of ultrasonic attenuation coefficients for advancedstructural ceramic materials. The procedure is based on a broadband buffered piezoelectric probe used in the pulse-echo contactmode and emitting either longitudinal or shear waves. The primary objective of this test method pr
4、actice is materialscharacterization.1.2 The procedure requires coupling an ultrasonic probe to the surface of a plate-like sample and the recovery of successivefront surface and back surface echoes. echoes (refer to Fig. 3). Power spectra of the echoes are used to calculate the attenuationspectrum (
5、attenuation coefficient as a function of ultrasonic frequency) for the sample material. The transducer bandwidth andspectral response are selected to cover a range of frequencies and corresponding wavelengths that interact with microstructuralfeatures of interest in solid test samples.1.3 The purpos
6、e of this test method practice is to establish fundamental procedures for measurement of ultrasonic attenuationcoefficients. These measurements should distinguish and quantify microstructural differences among solid samples and thereforehelp establish a reference database for comparing materials and
7、 calibrating ultrasonic attenuation measurement equipment.1.4 This test method practice applies to monolithic ceramics and also polycrystalline metals. This test method practice may beapplied to whisker reinforced ceramics, particulate toughened ceramics, and ceramic composites provided that similar
8、 constraintson sample size, shape, and finish are met as described herein for monolithic ceramics.1.5 This test method practice sets forth the constraints on sample size, shape, and finish that will assure valid attenuationcoefficient measurements. This test method practice also describes the instru
9、mentation, methods, and data processing proceduresfor accomplishing the measurements.1.6 This test method practice is not recommended for highly attenuating materials such as very thick, very porous,rough-surfaced monolithics or composites. This test method practice is not recommended for highly non
10、uniform, heterogeneous,cracked, defective, or otherwise flaw-ridden samples that are unrepresentative of the nature or inherent characteristics of thematerial under examination.1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the respon
11、sibilityof the user of this standard to establish appropriate safety safety, health, and healthenvironmental practices and determine theapplicability of regulatory limitations prior to use.1.8 This international standard was developed in accordance with internationally recognized principles on stand
12、ardizationestablished in the Decision on Principles for the Development of International Standards, Guides and Recommendations issuedby the World Trade Organization Technical Barriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2C1331 Practice for Measuring UltrasonicVelocity
13、inAdvanced Ceramics with Broadband Pulse-Echo Cross-Correlation MethodE543 Specification for Agencies Performing Nondestructive Testing1 This test method practice is under the jurisdiction of ASTM Committee E07 on Nondestructive Testing and is the direct responsibility of Subcommittee E07.06 onUltra
14、sonic Method.Current edition approved Feb. 1, 2013Feb. 1, 2018. Published April 2013February 2018. Originally approved in 1996. Last previous edition approved in 20072013 asC1332C1332 01 (2013). 01 (2007). DOI: 10.1520/C1332-01R13. DOI: 10.1520/C1332-18.2 For referencedASTM standards, visit theASTM
15、website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indic
16、ation of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be co
17、nsidered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1E664E664/E664M Practice for the Measurement of the Apparent Attenuation of Longitudinal Ul
18、trasonic Waves by ImmersionMethodE1316 Terminology for Nondestructive ExaminationsE1495E1495/E1495M Guide for Acousto-Ultrasonic Assessment of Composites, Laminates, and Bonded Joints2.2 ASNT Document:Documents:3Recommended Practice SNT-TC-1A for Nondestructive Testing Personnel Qualification and Ce
19、rtificationANSI/ASNT CP-189 Standard for Qualification and Certification of Nondestructive Testing Personnel2.3 MilitaryISO Standard:MIL-STD-410 ISO 9712 Nondestructive Testing Personnel Qualification Non-destructive Testing Qualification and Certifi-cation of NDT Personnel42.4 Aerospace Industries
20、Association Document:NAS 410 Certification and Qualification of Nondestructive Testing Personnel52.5 Additional references are cited in the text and at end of this test method.practice.3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 acoustic impedance (Z)a property (1)6 define
21、d by a materials density, p, and the velocity of sound within it, v, whereZ = v.3.1.2 attenuation coeffcient ()decrease in ultrasound intensity with distance expressed in nepers (Np) per unit length, herein, = ln(I0/I)/d, where is attenuation coefficient, d is path length or distance, I0 is original
22、 intensity and I is attenuated intensity(2).3.1.3 attenuation spectrumthe attenuation coefficient, , expressed as a function of ultrasonic frequency, f, or plotted as versus f, over a range of ultrasonic frequencies within the bandwidth of the transducer and associated pulser-receiverinstrumentation
23、.3.1.4 back surfacethe surface of a test sample which is opposite to the front surface and from which back surface echoes arereturned at normal incidence directly to the transducer.3.1.5 bandwidththe frequency range of an ultrasonic probe, defined by convention as the difference between the lower an
24、dupper frequencies at which the signal amplitude is 6 dB down from the frequency at which maximum signal amplitude occurs. Thefrequency at which the maximum occurs is termed the center frequency of the probe or transducer.3.1.6 broadband transduceran ultrasonic transducer capable of sending and rece
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC13322018STANDARDPRACTICEFORMEASUREMENTOFULTRASONICATTENUATIONCOEFFICIENTSOFADVANCEDCERAMICSBYPULSEECHOCONTACTTECHNIQUE

链接地址:http://www.mydoc123.com/p-464267.html