ASTM C114-2010a Standard Test Methods for Chemical Analysis of Hydraulic Cement《水凝水泥化学分析的标准试验方法》.pdf
《ASTM C114-2010a Standard Test Methods for Chemical Analysis of Hydraulic Cement《水凝水泥化学分析的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C114-2010a Standard Test Methods for Chemical Analysis of Hydraulic Cement《水凝水泥化学分析的标准试验方法》.pdf(32页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C114 10aStandard Test Methods forChemical Analysis of Hydraulic Cement1This standard is issued under the fixed designation C114; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in pa
2、rentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 These test methods cover the chemical analyses ofhydraulic cements. Any test methods of demonstrated accept-able precision and bias may be used fo
3、r analysis of hydrauliccements, including analyses for referee and certification pur-poses, as explained in Section 3. Specific chemical testmethods are provided for ease of reference for those desiring touse them. They are grouped as Reference Test Methods andAlternative Test Methods. The reference
4、 test methods are longaccepted classical chemical test methods which provide areasonably well-integrated basic scheme of analysis for hy-draulic cements. The alternative test methods generally provideindividual determination of specific analytes and may be usedalone or as alternates and determinatio
5、ns within the basicscheme at the option of the analyst and as indicated in theindividual method.1.2 Contents:Section Subject2 Referenced Documents3 Description of Referee Analyses3.1 Referee Analyses4 Qualification for Different Analyses4.1 Certified Reference Materials4.2 Requirements for Qualifica
6、tion Testing4.3 Alternative Analyses4.4 Performance Requirements for Rapid Test Methods5 General5.1 Interferences and Limitations5.2 Apparatus and Materials5.3 Reagents5.4 Sample Preparation5.5 General Procedures5.6 Recommended Order for Reporting AnalysesReference Test Methods6 Insoluble Residue7 S
7、ilicon Dioxide7.2 Cements with Insoluble Residue Less Than 1 %7.3 Cements with Insoluble Residue Greater Than 1 %8 Ammonium Hydroxide Group9 Ferric Oxide10 Phosphorus Pentoxide11 Titanium Dioxide12 Zinc Oxide13 Aluminum Oxide14 Calcium Oxide15 Magnesium Oxide16 Sulfur16.1 Sulfur Trioxide16.2 Sulfide
8、17 Loss On Ignition17.1 Portland Cement17.2 Portland Blast-Furnace Slag Cement and Slag Cement18 Sodium and Potassium Oxides18.1 Total Alkalis18.2 Water-Soluble Alkalis19 Manganic Oxide20 Chloride21 Chloroform-Soluble Organic SubstancesAlternative Test Methods22 Calcium Oxide23 Carbon Dioxide24 Magn
9、esium Oxide25 Loss on Ignition25.1 Portland Blast-Furnace Slag Cement and Slag Cement26 Titanium Dioxide27 Phosphorus Pentoxide28 Manganic Oxide29 Free Calcium OxideAppendices TitleAppendix X1 Example of Determination of Equivalence Pointfor the Chloride DeterminationAppendix X2 CO2Determinations in
10、 Hydraulic Cements1.3 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard
11、 to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. See 7.3.2.1 and15.4.1 for specific caution statements.2. Referenced Documents2.1 ASTM Standards:2C25 Test Methods for Chemical Analysis of Limestone,Quicklime, and Hydrated
12、 LimeD1193 Specification for Reagent WaterE29 Practice for Using Significant Digits in Test Data toDetermine Conformance with Specifications1These test methods are under the jurisdiction of ASTM Committee C01 onCement and are the direct responsibility of Subcommittee C01.23 on CompositionalAnalysis.
13、Current edition approved Dec. 1, 2010. Published January 2011. Originallyapproved in 1934. Last previous edition approved in 2010 as C11410. DOI:10.1520/C0114-10a.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book
14、 of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.E275 Practice for
15、 Describing and Measuring Performanceof Ultraviolet and Visible SpectrophotometersE350 Test Methods for Chemical Analysis of Carbon Steel,Low-Alloy Steel, Silicon Electrical Steel, Ingot Iron, andWrought IronE617 Specification for Laboratory Weights and PrecisionMass StandardsE832 Specification for
16、Laboratory Filter Papers3. Description of Referee Analyses3.1 Referee AnalysesWhen conformance to chemicalspecification requirements is questioned, perform refereeanalyses as described in 3.1.1. The reference test methods thatfollow in Sections 6-21, or other test methods qualifiedaccording to 4.4,
17、the Performance Requirements for Rapid TestMethods Section, are required for referee analysis. A cementshall not be rejected for failure to conform to chemicalrequirements unless all determinations of constituents involvedand all necessary separations prior to the determination of anyone constituent
18、 are made entirely by these methods. Whenreporting the results of referee analyses, specify which testmethods were used.3.1.1 Referee analyses shall be made in duplicate and theanalyses shall be made on different days. If the two results donot agree within the permissible variation given in Table 1,
19、 thedetermination shall be repeated until two or three results agreewithin the permissible variation. When two or three results doagree within the permissible variation, their average shall beaccepted as the correct value. When an average of either two orthree results can be calculated, the calculat
20、ion shall be based onthe three results. For the purpose of comparing analyses andcalculating the average of acceptable results, the percentagesshall be calculated to the nearest 0.01 (or 0.001 in the case ofchloroform-soluble organic substances), although some of theaverage values are reported to 0.
21、1 as indicated in the testmethods. When a blank determination (See Note 1) is speci-fied, one shall be made with each individual analysis or witheach group of two or more samples analyzed on the same dayfor a given analyte.NOTE 1A blank determination is a procedure which follows all stepsof analysis
22、 but in the absence of a sample. It is used for detection andcompensation of systematic bias.4. Qualification for Different Analyses4.1 Certified Reference MaterialsA Certified ReferenceMaterial (CRM) must be used in the qualification of testmethods and analysts. Acceptable reference cements are NIS
23、TCRMs, or other reference cements traceable to the NISTCRMs. The reference cement must have an assigned value forthe analyte being determined. Traceability consists of docu-mentary evidence that the assigned values of the referencecement are compatible with the certified values of NISTCRMs. To demon
24、strate traceability for a given analyte, per-form a referee analysis (as defined in 3.1) on the proposedreference cement, using a NIST CRM for demonstration ofprecision and accuracy. The reference cement is acceptable ifits assigned value agrees with the average referee value withinthe limits given
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC1142010ASTANDARDTESTMETHODSFORCHEMICALANALYSISOFHYDRAULICCEMENT 水泥 化学分析 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-463515.html