ASTM B496-2016 Standard Specification for Compact Round Concentric-Lay-Stranded Copper Conductors《紧凑型圆形同心式绞合铜导体的标准规格》.pdf
《ASTM B496-2016 Standard Specification for Compact Round Concentric-Lay-Stranded Copper Conductors《紧凑型圆形同心式绞合铜导体的标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM B496-2016 Standard Specification for Compact Round Concentric-Lay-Stranded Copper Conductors《紧凑型圆形同心式绞合铜导体的标准规格》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: B496 16Standard Specification forCompact Round Concentric-Lay-Stranded CopperConductors1This standard is issued under the fixed designation B496; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revisio
2、n. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers bare compact roundconcentric-lay-stranded conductors made from uncoated roundcopper wires for general us
3、e for electrical purposes. Theseconductors shall be constructed with a central core surroundedby one or more layers of helically laid compacted wires(Explanatory Note 1 and Note 2).1.2 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematic
4、alconversions to SI units that are provided for information onlyand are not considered standard.1.2.1 For density, resistivity, and temperature, the valuesstated in SI units are to be regarded as standard.2. Referenced Documents2.1 The following documents of the issue in effect on dateof material pu
5、rchase form a part of this specification to theextent referenced herein:2.2 ASTM Standards:2B3 Specification for Soft or Annealed Copper WireB263 Test Method for Determination of Cross-SectionalArea of Stranded ConductorsB354 Terminology Relating to Uninsulated Metallic Electri-cal Conductors3. Orde
6、ring Information3.1 Orders for material under this specification shall includethe following information:3.1.1 Quantity of each size (Table 1),3.1.2 Conductor size; circular-mil area or AWG, (Section 6and Table 1),3.1.3 Packaging (Section 15), if required,3.1.4 Special package marking, and3.1.5 Place
7、 of inspection (Section 14).4. Joints4.1 Welds and brazes may be made in rods or in wires priorto final drawing.4.2 Welds and brazes may be made in the individual rounddrawn wires for compact conductors, but shall not be closertogether than 1 ft (300 mm) for conductor of 19 wires or lessor closer th
8、an 1 ft (300 mm) in a layer for conductor of morethan 19 wires.4.3 No joint nor splice shall be made in a compact-strandedconductor as a whole.5. Lay5.1 The length of lay of the outer layer shall not be less than8 nor more than 16 times the outside diameter of the completedconductor. The maximum len
9、gth of lay for compact conductorsAWG 2 (33.6 mm2) and smaller shall be 17.5 times the outsidediameter of the conductor.5.2 The direction of lay of the outer layer shall be left-hand,and it shall be reversed in successive layers, unidirectional, orunilay.6. Construction6.1 The construction of the com
10、pact round concentric-lay-stranded conductors shall be as shown in Table 1.6.2 The starting round copper wires used in the fabricationof the compact round conductor shall be of such diameter as toproduce a finished conductor having a nominal cross-sectionalarea and diameter as prescribed in Table 1.
11、7. Density7.1 For the purpose of calculating linear densities, crosssections, and so forth, the density of the copper shall be takenas 8.89 g/cm3(0.32117 lb/in.3) at 20C.8. Mass and Resistance8.1 The mass per unit length and dc electrical resistance ofa compact round conductor are greater than the t
12、otal of thesecharacteristics of the compressed wires composing the finished1This specification is under the jurisdiction of ASTM Committee B01 onElectrical Conductors and is the direct responsibility of Subcommittee B01.04 onConductors of Copper and Copper Alloys.Current edition approved April 1, 20
13、16. Published May 2016. Originallyapproved in 1969. Last previous edition approved in 2014 as B496 14. DOI:10.1520/B0496-16.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, r
14、efer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1conductor, depending upon the lay. The standard increment ofmass per unit length and electrical resistance shall be taken a
15、s2 %. The nominal mass per unit length and dc resistance areshown in Table 1. When the dc resistance is measured at otherthan 20C, it shall be corrected by using the multiplying factorsgiven in Table 2.8.2 In cases where the lay is definitely known, the incrementmay be calculated if desired (Explana
16、tory Note 3).8.3 For conductors to be used in covered or insulated wiresor cables, direct current (DC) resistance measurement may beused instead of the method outlined in Section 9, to determinecompliance with this specification.9. Variation in Area9.1 The cross-sectional area of the compact round c
17、onductorshall be not less than 98 % of the cross-sectional area asspecified in Column 1 of Table 1.9.2 The manufacturer shall determine the cross-sectionalarea by Test Method B263. In applying this method, theincrement in mass per unit length resulting from stranding maybe the applicable value speci
18、fied in 9.1 or may be calculatedfrom the measured dimensions of the sample under test. In caseof question regarding area compliance, the actual mass per unitlength increment due to stranding shall be calculated.10. Variation in Diameter10.1 The average diameter of the compact-round conductorshall no
19、t vary by more than +1 % and 2 % from the diameterspecified in Table 1.TABLE 1 Construction Requirements of Compact Round Concentric-Lay-Stranded Copper ConductorsConductor SizeNumber ofWiresNominal Compact ConductorDiameterNominal Mass,lb/1000 ftNominal Mass,kg/kmNominal DC Resistance at20Ccmil AWG
20、 mm2in. mm /1000 ft /km1 500 000 . 760 91A,B1.299 33.0 4631 6892 0.00705 0.02311 250 000 . 633 91A,B1.184 30.1 3859 5743 0.00846 0.02781 100 000 . 557 91A,B1.112 28.2 3396 5054 0.00962 0.03161 000 000 . 507 61C1.060 26.9 3086 4590 0.0106 0.0347900 000 . 456 61C0.999 25.4 2780 4140 0.0118 0.0386800 0
21、00 . 405 61C0.938 23.8 2469 3680 0.0132 0.0433750 000 . 380 61C0.908 23.0 2316 3450 0.0141 0.0462700 000 . 355 61C0.877 22.3 2160 3220 0.0151 0.0495650 000 . 329 61C0.845 21.4 2006 2990 0.0163 0.0535600 000 . 304 61C0.813 20.6 1850 2760 0.0176 0.0577550 000 . 279 61C0.775 19.7 1700 2530 0.0192 0.063
22、0500 000 . 253 37D0.736 18.7 1542 2300 0.0212 0.0695450 000 . 228 37D0.700 17.8 1390 2070 0.0235 0.0770400 000 . 203 37D0.659 16.7 1236 1840 0.0264 0.0865350 000 . 177 37D0.616 15.7 1080 1610 0.0302 0.0990300 000 . 152 37D0.570 14.5 925 1380 0.0353 0.116250 000 . 127 37D0.520 13.2 772 1150 0.0423 0.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMB4962016STANDARDSPECIFICATIONFORCOMPACTROUNDCONCENTRICLAYSTRANDEDCOPPERCONDUCTORS 紧凑型 圆形 同心 式绞合铜

链接地址:http://www.mydoc123.com/p-461394.html